PCI 高出血风险患者使用超薄支架与薄支架的比较:COMPARE 60/80 HBR 试验结果:一项开放标签、随机对照试验。

IF 6.1 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Circulation: Cardiovascular Interventions Pub Date : 2024-10-01 DOI:10.1161/CIRCINTERVENTIONS.123.014042
Pieter C Smits, Pim A L Tonino, Sjoerd H Hofma, Jan-Peter van Kuijk, Fabrizio Spano, Amar Al Mafragi, Ron Pisters, Jawed Polad, Kris Bogaerts, Rohit M Oemrawsingh, Valeria Paradies
{"title":"PCI 高出血风险患者使用超薄支架与薄支架的比较:COMPARE 60/80 HBR 试验结果:一项开放标签、随机对照试验。","authors":"Pieter C Smits, Pim A L Tonino, Sjoerd H Hofma, Jan-Peter van Kuijk, Fabrizio Spano, Amar Al Mafragi, Ron Pisters, Jawed Polad, Kris Bogaerts, Rohit M Oemrawsingh, Valeria Paradies","doi":"10.1161/CIRCINTERVENTIONS.123.014042","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting.</p><p><strong>Methods: </strong>In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha.</p><p><strong>Results: </strong>Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; <i>P</i>=0.02 for noninferiority at a 0.025 significance level and <i>P</i>=0.55 for 2-sided superiority at a 0.05 significance level).</p><p><strong>Conclusions: </strong>Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent.</p><p><strong>Registration: </strong>URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.</p>","PeriodicalId":10330,"journal":{"name":"Circulation: Cardiovascular Interventions","volume":" ","pages":"e014042"},"PeriodicalIF":6.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472898/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of Ultrathin- Versus Thin-Strut Stents in Patients With High Bleeding Risk PCI: Results From the COMPARE 60/80 HBR Trial: An Open-Label, Randomized, Controlled Trial.\",\"authors\":\"Pieter C Smits, Pim A L Tonino, Sjoerd H Hofma, Jan-Peter van Kuijk, Fabrizio Spano, Amar Al Mafragi, Ron Pisters, Jawed Polad, Kris Bogaerts, Rohit M Oemrawsingh, Valeria Paradies\",\"doi\":\"10.1161/CIRCINTERVENTIONS.123.014042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting.</p><p><strong>Methods: </strong>In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha.</p><p><strong>Results: </strong>Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; <i>P</i>=0.02 for noninferiority at a 0.025 significance level and <i>P</i>=0.55 for 2-sided superiority at a 0.05 significance level).</p><p><strong>Conclusions: </strong>Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent.</p><p><strong>Registration: </strong>URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.</p>\",\"PeriodicalId\":10330,\"journal\":{\"name\":\"Circulation: Cardiovascular Interventions\",\"volume\":\" \",\"pages\":\"e014042\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472898/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation: Cardiovascular Interventions\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCINTERVENTIONS.123.014042\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation: Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCINTERVENTIONS.123.014042","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:目前还没有关于冠状动脉支架术后接受简短双联抗血小板疗法的高出血风险(HBR)患者使用超薄支架的随机数据。本研究旨在比较超薄支架生物可降解聚合物西罗莫司洗脱 Supraflex Cruz 支架与薄支架生物可降解聚合物西罗莫司洗脱 Ultimaster Tansei 支架在支架术后接受简短双联抗血小板疗法的高出血风险患者中的安全性和有效性:在研究者发起的随机、开放标签 COMPARE 60/80 HBR 试验(Supraflex Cruz 60 微米支架与 Ultimaster Tansei 80 微米支架在 HBR 经皮冠状动脉介入人群中的比较)中、根据学术研究联盟 HBR 标准,741 名 HBR 患者被随机分配接受超薄支架生物可降解聚合物西罗莫司洗脱 Supraflex Cruz 支架或薄支架生物可降解聚合物西罗莫司洗脱 Ultimaster Tansei 支架。根据适用的指南和试验数据,建议HBR患者使用双联抗血小板疗法。主要结果为净不良临床事件,即心血管死亡、心肌梗死、靶血管血运重建、中风和大出血的复合结果:2020年9月至2022年8月期间,在荷兰的11个地点,371名患者被随机分配到超薄支架生物可降解聚合物西罗莫司洗脱Supraflex Cruz支架,370名患者被随机分配到薄支架生物可降解聚合物西罗莫司洗脱Ultimaster Tansei支架。1年后,超薄支架生物可降解聚合物西罗莫司洗脱Supraflex Cruz支架组有56例(15.4%)患者观察到主要结果,薄支架生物可降解聚合物西罗莫司洗脱Ultimaster Tansei支架组有61例(17.1%)患者观察到主要结果(风险差异为-1.65%;单侧 95% CI 上限为 3.74;在 0.025 显著性水平下,非劣效性 P=0.02 ;在 0.05 显著性水平下,双侧优效性 P=0.55):结论:在支架术后接受简短双联抗血小板治疗的HBR患者中,使用超薄支架生物可降解聚合物西罗莫司洗脱Supraflex Cruz支架与使用薄支架生物可降解聚合物西罗莫司洗脱Ultimaster Tansei支架相比并无劣效:URL:https://www.clinicaltrials.gov;唯一标识符:NCT04500912。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Ultrathin- Versus Thin-Strut Stents in Patients With High Bleeding Risk PCI: Results From the COMPARE 60/80 HBR Trial: An Open-Label, Randomized, Controlled Trial.

Background: No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting.

Methods: In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha.

Results: Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; P=0.02 for noninferiority at a 0.025 significance level and P=0.55 for 2-sided superiority at a 0.05 significance level).

Conclusions: Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent.

Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Circulation: Cardiovascular Interventions
Circulation: Cardiovascular Interventions CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
1.80%
发文量
221
审稿时长
6-12 weeks
期刊介绍: Circulation: Cardiovascular Interventions, an American Heart Association journal, focuses on interventional techniques pertaining to coronary artery disease, structural heart disease, and vascular disease, with priority placed on original research and on randomized trials and large registry studies. In addition, pharmacological, diagnostic, and pathophysiological aspects of interventional cardiology are given special attention in this online-only journal.
期刊最新文献
Contemporary Outcomes of TAVR Using a Balloon-Expandable Valve in Patients With Severe Mitral Stenosis: Insights From the Transcatheter Valve Therapies Registry. Comparison of Transcatheter versus Surgical Tricuspid Repair among Patients with Tricuspid Regurgitation: Two-Year Results. Virtual Reality for Preprocedure Planning of Covered Stent Correction of Superior Sinus Venosus Atrial Septal Defects. ELLIS Study: Comparative Analysis of Excimer Laser Coronary Angioplasty and Intravascular Lithotripsy on Drug-Eluting Stent as Assessed by Scanning Electron Microscopy. Three-Year Outcomes Following TAVR in Younger (<75 Years) Low-Surgical-Risk Severe Aortic Stenosis Patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1