{"title":"新型人体工学护套对牙科设备相关肌肉工作、疲劳和舒适度的影响--一项试点临床研究。","authors":"Steven Dang, Cherie Wink, Susan Meishan Yang, Kairong Lin, Thair Takesh, Ali A Habib, Petra Wilder-Smith","doi":"10.3390/dj12090296","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Dental instrumentation with hand-held devices is associated with discomfort, fatigue and musculoskeletal diseases or repetitive stress injuries. The goal of this in vivo study was to determine the effect of an ergonomic handle sheath on muscle work, comfort and fatigue associated with (a) piezoelectric scaling by hygienists with and without musculoskeletal disorders (MSDs), and (b) dental cavity preparation by healthy dentists using a dental micromotor. <b>Materials and Methods:</b> Two groups of ten hygienists each tested the piezoelectric scaler. Hygienists in Group 1 had no MSDs, while those in Group 2 had been diagnosed with MSDs. Additionally, ten dentists with no MSDs used a dental micromotor to prepare four standardized cavities. Time-based work in four muscles, comfort and fatigue were recorded in the presence and absence of an add-on soft, insulating handle sheath. Data were analyzed using a repeated measures analysis of variance model with Tukey's post-hoc test. <b>Results:</b> Comfort, fatigue and muscle work were significantly better for both devices when the sheath was used. While hygienists with MSDs used more muscle work to complete the set scaling task, and the sheath-related reduction in work was somewhat greater, these MSD-related differences did not quite reach significance. <b>Conclusions:</b> The results of this pilot study show that the ergonomic performance of an ultrasonic scaler and a dental micromotor may be improved by the use of an ergonomic handle sheath.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11431630/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of a Novel Ergonomic Sheath on Dental Device-Related Muscle Work, Fatigue and Comfort-A Pilot Clinical Study.\",\"authors\":\"Steven Dang, Cherie Wink, Susan Meishan Yang, Kairong Lin, Thair Takesh, Ali A Habib, Petra Wilder-Smith\",\"doi\":\"10.3390/dj12090296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Dental instrumentation with hand-held devices is associated with discomfort, fatigue and musculoskeletal diseases or repetitive stress injuries. The goal of this in vivo study was to determine the effect of an ergonomic handle sheath on muscle work, comfort and fatigue associated with (a) piezoelectric scaling by hygienists with and without musculoskeletal disorders (MSDs), and (b) dental cavity preparation by healthy dentists using a dental micromotor. <b>Materials and Methods:</b> Two groups of ten hygienists each tested the piezoelectric scaler. Hygienists in Group 1 had no MSDs, while those in Group 2 had been diagnosed with MSDs. Additionally, ten dentists with no MSDs used a dental micromotor to prepare four standardized cavities. Time-based work in four muscles, comfort and fatigue were recorded in the presence and absence of an add-on soft, insulating handle sheath. Data were analyzed using a repeated measures analysis of variance model with Tukey's post-hoc test. <b>Results:</b> Comfort, fatigue and muscle work were significantly better for both devices when the sheath was used. While hygienists with MSDs used more muscle work to complete the set scaling task, and the sheath-related reduction in work was somewhat greater, these MSD-related differences did not quite reach significance. <b>Conclusions:</b> The results of this pilot study show that the ergonomic performance of an ultrasonic scaler and a dental micromotor may be improved by the use of an ergonomic handle sheath.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11431630/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj12090296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12090296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:使用手持设备进行牙科器械操作会引起不适、疲劳、肌肉骨骼疾病或重复性应力损伤。这项体内研究的目的是确定符合人体工程学的手柄护套对肌肉工作、舒适度和疲劳的影响,这些工作与(a)患有和未患有肌肉骨骼疾病(MSDs)的卫生学家进行压电洗牙有关,以及(b)健康牙医使用牙科微电机进行牙腔预备有关。材料和方法:两组各有十名卫生员测试压电洁牙机。第 1 组的卫生员没有 MSD,而第 2 组的卫生员已被诊断出患有 MSD。此外,十名没有 MSD 的牙医使用牙科微电机制备了四个标准龋齿。在有无附加软绝缘手柄护套的情况下,记录了四块肌肉的工作时间、舒适度和疲劳度。数据采用重复测量方差分析模型和 Tukey 事后检验进行分析。结果显示使用护套时,两种器械的舒适度、疲劳度和肌肉工作量都明显更好。虽然患有 MSD 的卫生学家在完成设定的洗牙任务时使用了更多的肌肉工作量,而且与护套相关的工作量减少幅度更大,但这些与 MSD 相关的差异并未达到显著性水平。结论:这项试点研究的结果表明,使用符合人体工程学的手柄护套可以提高超声波洁牙机和牙科微电机的人体工程学性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of a Novel Ergonomic Sheath on Dental Device-Related Muscle Work, Fatigue and Comfort-A Pilot Clinical Study.

Background: Dental instrumentation with hand-held devices is associated with discomfort, fatigue and musculoskeletal diseases or repetitive stress injuries. The goal of this in vivo study was to determine the effect of an ergonomic handle sheath on muscle work, comfort and fatigue associated with (a) piezoelectric scaling by hygienists with and without musculoskeletal disorders (MSDs), and (b) dental cavity preparation by healthy dentists using a dental micromotor. Materials and Methods: Two groups of ten hygienists each tested the piezoelectric scaler. Hygienists in Group 1 had no MSDs, while those in Group 2 had been diagnosed with MSDs. Additionally, ten dentists with no MSDs used a dental micromotor to prepare four standardized cavities. Time-based work in four muscles, comfort and fatigue were recorded in the presence and absence of an add-on soft, insulating handle sheath. Data were analyzed using a repeated measures analysis of variance model with Tukey's post-hoc test. Results: Comfort, fatigue and muscle work were significantly better for both devices when the sheath was used. While hygienists with MSDs used more muscle work to complete the set scaling task, and the sheath-related reduction in work was somewhat greater, these MSD-related differences did not quite reach significance. Conclusions: The results of this pilot study show that the ergonomic performance of an ultrasonic scaler and a dental micromotor may be improved by the use of an ergonomic handle sheath.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
期刊最新文献
Asymmetric Dimethylarginine as a Potential Mediator in the Association between Periodontitis and Cardiovascular Disease: A Systematic Review of Current Evidence. Effect of a Novel Ergonomic Sheath on Dental Device-Related Muscle Work, Fatigue and Comfort-A Pilot Clinical Study. Evaluating Treatment Modalities for Reducing Recurrence in Central Giant Cell Granuloma: A Narrative Review. Influence of Direct Coronal Restoration Materials on the Fracture Resistance of Endodontically Treated Premolars: An In Vitro Study. Clinical Performance of Extra-Short (≤5.5 mm) Compared to Longer Implants Splinted under the Same Prosthesis: A Randomized Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1