二硅酸锂陶瓷试瓷后应用的清洁方法评估:SEM 分析。

IF 2.5 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Dentistry Journal Pub Date : 2024-08-31 DOI:10.3390/dj12090281
Gildo Coelho Santos Junior, Maria Jacinta Moraes Coelho Santos
{"title":"二硅酸锂陶瓷试瓷后应用的清洁方法评估:SEM 分析。","authors":"Gildo Coelho Santos Junior, Maria Jacinta Moraes Coelho Santos","doi":"10.3390/dj12090281","DOIUrl":null,"url":null,"abstract":"<p><p>This in vitro study assessed the efficacy of three cleaning methods on lithium disilicate ceramic after the application of different try-in pastes through SEM analysis. Ten rectangular specimens of IPS e.max CAD were prepared using a diamond disc, crystallized, etched with 5% hydrofluoric acid, and subjected to three try-in pastes-Calibra ©, Variolink (V), RelyX Veneer<sup>®</sup>-and three cleaning techniques-air-water spray (RD), ultrasonic bath in distilled water for five minutes (ULT/W), and ultrasonic bath in distilled alcohol for five minutes (ULT/A). A control specimen was also included. After one-minute paste application and subsequent cleaning method application, SEM evaluation was conducted. The results indicate that RD was as effective as CTRL in removing remnants from R-RD, V-ULT/W and V-ULT/A samples, but ineffective for all Calibra paste-contaminated specimens. In conclusion, the optimal removal of try-in paste residues from lithium disilicate restorations is paste-dependent; however, ultrasonic baths with distilled water or alcohol proved effective for most pastes tested.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"12 9","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11431432/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Cleaning Methods for Lithium Disilicate Ceramic Post Try-In Paste Application: An SEM Analysis.\",\"authors\":\"Gildo Coelho Santos Junior, Maria Jacinta Moraes Coelho Santos\",\"doi\":\"10.3390/dj12090281\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This in vitro study assessed the efficacy of three cleaning methods on lithium disilicate ceramic after the application of different try-in pastes through SEM analysis. Ten rectangular specimens of IPS e.max CAD were prepared using a diamond disc, crystallized, etched with 5% hydrofluoric acid, and subjected to three try-in pastes-Calibra ©, Variolink (V), RelyX Veneer<sup>®</sup>-and three cleaning techniques-air-water spray (RD), ultrasonic bath in distilled water for five minutes (ULT/W), and ultrasonic bath in distilled alcohol for five minutes (ULT/A). A control specimen was also included. After one-minute paste application and subsequent cleaning method application, SEM evaluation was conducted. The results indicate that RD was as effective as CTRL in removing remnants from R-RD, V-ULT/W and V-ULT/A samples, but ineffective for all Calibra paste-contaminated specimens. In conclusion, the optimal removal of try-in paste residues from lithium disilicate restorations is paste-dependent; however, ultrasonic baths with distilled water or alcohol proved effective for most pastes tested.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":\"12 9\",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11431432/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj12090281\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12090281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

这项体外研究通过扫描电子显微镜分析,评估了三种清洁方法在二硅酸锂陶瓷上使用不同试入膏后的效果。使用金刚石圆盘制备了十个矩形的 IPS e.max CAD 试样,结晶后用 5% 氢氟酸腐蚀,并使用三种试入膏--Calibra ©、Variolink (V)、RelyX Veneer® 和三种清洁技术--空气-水喷雾 (RD)、蒸馏水中超声波浴五分钟 (ULT/W) 和蒸馏酒精中超声波浴五分钟 (ULT/A)。还包括一个对照试样。在涂抹一分钟的浆料并随后使用清洁方法后,进行了扫描电镜评估。结果表明,在清除 R-RD、V-ULT/W 和 V-ULT/A 试样中的残留物方面,RD 与 CTRL 一样有效,但对所有被 Calibra 浆糊污染的试样无效。总之,从二硅酸锂修复体中去除试入膏残留物的最佳方法取决于试入膏;不过,使用蒸馏水或酒精进行超声波浴证明对大多数测试的试入膏都有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Cleaning Methods for Lithium Disilicate Ceramic Post Try-In Paste Application: An SEM Analysis.

This in vitro study assessed the efficacy of three cleaning methods on lithium disilicate ceramic after the application of different try-in pastes through SEM analysis. Ten rectangular specimens of IPS e.max CAD were prepared using a diamond disc, crystallized, etched with 5% hydrofluoric acid, and subjected to three try-in pastes-Calibra ©, Variolink (V), RelyX Veneer®-and three cleaning techniques-air-water spray (RD), ultrasonic bath in distilled water for five minutes (ULT/W), and ultrasonic bath in distilled alcohol for five minutes (ULT/A). A control specimen was also included. After one-minute paste application and subsequent cleaning method application, SEM evaluation was conducted. The results indicate that RD was as effective as CTRL in removing remnants from R-RD, V-ULT/W and V-ULT/A samples, but ineffective for all Calibra paste-contaminated specimens. In conclusion, the optimal removal of try-in paste residues from lithium disilicate restorations is paste-dependent; however, ultrasonic baths with distilled water or alcohol proved effective for most pastes tested.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
期刊最新文献
Home Biofilm Management in Orthodontic Aligners: A Systematic Review. In Vitro Research Methods Used to Evaluate Shaping Ability of Rotary Endodontic Files-A Literature Review. Accuracy and Efficiency of the Surgical-Guide-Assisted Fiber Post Removal Technique for Anterior Teeth: An Ex Vivo Study. Correlation between Periodontitis and Onset of Alzheimer's Disease: A Literature Review. The Harmful Effects of Welding Fumes on Human Dental Enamel-A Microhardness Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1