进行性核上性麻痹中[18F]Florzolotau Tau PET扫描的视觉读数。

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING European Journal of Nuclear Medicine and Molecular Imaging Pub Date : 2025-01-01 Epub Date: 2024-10-01 DOI:10.1007/s00259-024-06923-3
Feng-Tao Liu, Jia-Ying Lu, Xin-Yi Li, Jing-Jie Ge, Yi-Min Sun, Tzu-Chen Yen, Fang-Yang Jiao, Ming-Jia Chen, Jun Zhao, Rui-Xin Yao, Gan Tang, Hao Xu, Xiao-Li Lan, Jie Lu, Rui-Xue Cui, Matthias Brendel, Kuangyu Shi, Yi-Hui Guan, Axel Rominger, Jian Wang, Chuan-Tao Zuo
{"title":"进行性核上性麻痹中[18F]Florzolotau Tau PET扫描的视觉读数。","authors":"Feng-Tao Liu, Jia-Ying Lu, Xin-Yi Li, Jing-Jie Ge, Yi-Min Sun, Tzu-Chen Yen, Fang-Yang Jiao, Ming-Jia Chen, Jun Zhao, Rui-Xin Yao, Gan Tang, Hao Xu, Xiao-Li Lan, Jie Lu, Rui-Xue Cui, Matthias Brendel, Kuangyu Shi, Yi-Hui Guan, Axel Rominger, Jian Wang, Chuan-Tao Zuo","doi":"10.1007/s00259-024-06923-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The identification of tau accumulation within living brains holds significant potential in facilitating accurate diagnosis of progressive supranuclear palsy (PSP). While visual assessment is frequently employed, standardized methods for tau positron emission tomography (PET) specifically in PSP are absent. We aimed to develop a visual reading algorithm dedicated to the evaluation of [<sup>18</sup>F]Florzolotau PET in PSP.</p><p><strong>Methods: </strong>148 PSP and 30 healthy volunteers were divided into a development set (for the establishment of the reading rules; n = 89) and a testing set (for the validation of the reading rules; n = 89). For differential diagnosis, 55 α-synucleinopathies were additionally included into the testing set. The visual reading method was established by an experienced assessor (Reader 0) and was then validated by Reader 0 and two additional readers on regional and overall binary manners. A positive binding in both midbrain and globus pallidus/putamen regions was characterized as a PSP-like pattern, whereas any other pattern was classified as non-PSP-like.</p><p><strong>Results: </strong>Reader 1 (94.4%) and Reader 2 (93.8%) showed excellent agreement for the overall binary determination against Reader 0. The regional binary determinations of midbrain and globus pallidus/putamen showed excellent agreement among readers (kappa > 0.80). The overall binary evaluation demonstrated reproducibility of 86.1%, 94.4% and 77.8% for three readers. The visual reading algorithm showed high agreement with regional standardized uptake value ratios and clinical diagnoses.</p><p><strong>Conclusion: </strong>Through the application of the suggested visual reading algorithm, [<sup>18</sup>F]Florzorotau PET imaging demonstrated a robust performance for the imaging diagnosis of PSP.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":" ","pages":"586-598"},"PeriodicalIF":8.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual reading for [<sup>18</sup>F]Florzolotau Tau PET scans in progressive supranuclear palsy.\",\"authors\":\"Feng-Tao Liu, Jia-Ying Lu, Xin-Yi Li, Jing-Jie Ge, Yi-Min Sun, Tzu-Chen Yen, Fang-Yang Jiao, Ming-Jia Chen, Jun Zhao, Rui-Xin Yao, Gan Tang, Hao Xu, Xiao-Li Lan, Jie Lu, Rui-Xue Cui, Matthias Brendel, Kuangyu Shi, Yi-Hui Guan, Axel Rominger, Jian Wang, Chuan-Tao Zuo\",\"doi\":\"10.1007/s00259-024-06923-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The identification of tau accumulation within living brains holds significant potential in facilitating accurate diagnosis of progressive supranuclear palsy (PSP). While visual assessment is frequently employed, standardized methods for tau positron emission tomography (PET) specifically in PSP are absent. We aimed to develop a visual reading algorithm dedicated to the evaluation of [<sup>18</sup>F]Florzolotau PET in PSP.</p><p><strong>Methods: </strong>148 PSP and 30 healthy volunteers were divided into a development set (for the establishment of the reading rules; n = 89) and a testing set (for the validation of the reading rules; n = 89). For differential diagnosis, 55 α-synucleinopathies were additionally included into the testing set. The visual reading method was established by an experienced assessor (Reader 0) and was then validated by Reader 0 and two additional readers on regional and overall binary manners. A positive binding in both midbrain and globus pallidus/putamen regions was characterized as a PSP-like pattern, whereas any other pattern was classified as non-PSP-like.</p><p><strong>Results: </strong>Reader 1 (94.4%) and Reader 2 (93.8%) showed excellent agreement for the overall binary determination against Reader 0. The regional binary determinations of midbrain and globus pallidus/putamen showed excellent agreement among readers (kappa > 0.80). The overall binary evaluation demonstrated reproducibility of 86.1%, 94.4% and 77.8% for three readers. The visual reading algorithm showed high agreement with regional standardized uptake value ratios and clinical diagnoses.</p><p><strong>Conclusion: </strong>Through the application of the suggested visual reading algorithm, [<sup>18</sup>F]Florzorotau PET imaging demonstrated a robust performance for the imaging diagnosis of PSP.</p>\",\"PeriodicalId\":11909,\"journal\":{\"name\":\"European Journal of Nuclear Medicine and Molecular Imaging\",\"volume\":\" \",\"pages\":\"586-598\"},\"PeriodicalIF\":8.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Nuclear Medicine and Molecular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00259-024-06923-3\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-06923-3","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:识别活体大脑中的 tau 积累对准确诊断进行性核上性麻痹(PSP)具有重要意义。虽然视觉评估经常被采用,但目前还没有专门针对 PSP 的 tau 正电子发射断层扫描(PET)的标准化方法。方法:148 名 PSP 患者和 30 名健康志愿者被分为开发组(用于建立阅读规则;n = 89)和测试组(用于验证阅读规则;n = 89)。为了进行鉴别诊断,测试组还包括 55 种 α-突触核蛋白病。视觉判读方法由一名经验丰富的评估员(0号判读员)制定,然后由0号判读员和另外两名判读员对区域和整体二元方式进行验证。中脑和球状苍白球/普门区域的阳性结合被定性为 PSP 样式,而任何其他模式则被归类为非 PSP 样式:读数 1(94.4%)和读数 2(93.8%)与读数 0 的整体二元判定结果显示出极好的一致性,读数之间在中脑和球状苍白球/肌图蛋白区域的二元判定结果显示出极好的一致性(kappa > 0.80)。三位读数员的整体二元评估重复性分别为 86.1%、94.4% 和 77.8%。视觉读数算法与区域标准化摄取值比率和临床诊断显示出高度的一致性:结论:通过应用建议的视觉读取算法,[18F]弗罗佐罗陶 PET 成像在 PSP 的成像诊断中表现出良好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Visual reading for [18F]Florzolotau Tau PET scans in progressive supranuclear palsy.

Purpose: The identification of tau accumulation within living brains holds significant potential in facilitating accurate diagnosis of progressive supranuclear palsy (PSP). While visual assessment is frequently employed, standardized methods for tau positron emission tomography (PET) specifically in PSP are absent. We aimed to develop a visual reading algorithm dedicated to the evaluation of [18F]Florzolotau PET in PSP.

Methods: 148 PSP and 30 healthy volunteers were divided into a development set (for the establishment of the reading rules; n = 89) and a testing set (for the validation of the reading rules; n = 89). For differential diagnosis, 55 α-synucleinopathies were additionally included into the testing set. The visual reading method was established by an experienced assessor (Reader 0) and was then validated by Reader 0 and two additional readers on regional and overall binary manners. A positive binding in both midbrain and globus pallidus/putamen regions was characterized as a PSP-like pattern, whereas any other pattern was classified as non-PSP-like.

Results: Reader 1 (94.4%) and Reader 2 (93.8%) showed excellent agreement for the overall binary determination against Reader 0. The regional binary determinations of midbrain and globus pallidus/putamen showed excellent agreement among readers (kappa > 0.80). The overall binary evaluation demonstrated reproducibility of 86.1%, 94.4% and 77.8% for three readers. The visual reading algorithm showed high agreement with regional standardized uptake value ratios and clinical diagnoses.

Conclusion: Through the application of the suggested visual reading algorithm, [18F]Florzorotau PET imaging demonstrated a robust performance for the imaging diagnosis of PSP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
期刊最新文献
Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner A hybrid [18F]fluoropivalate PET-multiparametric MRI to detect and characterise brain tumour metastases based on a permissive environment for monocarboxylate transport Robust whole-body PET image denoising using 3D diffusion models: evaluation across various scanners, tracers, and dose levels Optimizing MR-based attenuation correction in hybrid PET/MR using deep learning: validation with a flatbed insert and consistent patient positioning Unveiling the potential of copper-61 vs. gallium-68 for SSTR PET imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1