德国双相情感障碍研究联盟(BipoLife):磁共振神经成像数据质量保证协议。

IF 2.8 2区 医学 Q2 PSYCHIATRY International Journal of Bipolar Disorders Pub Date : 2024-09-26 DOI:10.1186/s40345-024-00354-7
Christoph Vogelbacher, Jens Sommer, Miriam H A Bopp, Irina Falkenberg, Philipp S Ritter, Felix Bermpohl, Catherine Hindi Attar, Karolin E Einenkel, Oliver Gruber, Georg Juckel, Vera Flasbeck, Martin Hautzinger, Andrea Pfennig, Silke Matura, Andreas Reif, Dominik Grotegerd, Udo Dannlowski, Tilo Kircher, Michael Bauer, Andreas Jansen
{"title":"德国双相情感障碍研究联盟(BipoLife):磁共振神经成像数据质量保证协议。","authors":"Christoph Vogelbacher, Jens Sommer, Miriam H A Bopp, Irina Falkenberg, Philipp S Ritter, Felix Bermpohl, Catherine Hindi Attar, Karolin E Einenkel, Oliver Gruber, Georg Juckel, Vera Flasbeck, Martin Hautzinger, Andrea Pfennig, Silke Matura, Andreas Reif, Dominik Grotegerd, Udo Dannlowski, Tilo Kircher, Michael Bauer, Andreas Jansen","doi":"10.1186/s40345-024-00354-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The German multicenter research consortium BipoLife aims to investigate the mechanisms underlying bipolar disorders. It focuses in particular on people at high risk of developing the disorder and young patients in the early stages of the disease. Functional and structural magnetic resonance imaging (MRI) data was collected in all participating centers. The collection of neuroimaging data in a longitudinal, multicenter study requires the implementation of a comprehensive quality assurance (QA) protocol. Here, we outline this protocol and illustrate its application within the BipoLife consortium.</p><p><strong>Methods: </strong>The QA protocol consisted of (1) a training of participating research staff, (2) regular phantom measurements to evaluate the MR scanner performance and its temporal stability across the course of the study, and (3) the assessment of the quality of human MRI data by evaluating a variety of image metrics (e.g., signal-to-noise ratio, ghosting level). In this article, we will provide an overview on these QA procedures and show exemplarily the influence of its application on the results of standard neuroimaging analysis pipelines.</p><p><strong>Discussion: </strong>The QA protocol helped to characterize the various MR scanners, to record their performance over the course of the study and to detect possible malfunctions at an early stage. It also assessed the quality of the human MRI data systematically to characterize its influence on various analyses. Furthermore, by setting up and publishing this protocol, we define standards that must be considered when analyzing data from the BipoLife consortium. It further promotes a systematic evaluation of data quality and a definition of subject inclusion criteria. In the long term, it will help to increase the chance of achieving clinically relevant results.</p>","PeriodicalId":13944,"journal":{"name":"International Journal of Bipolar Disorders","volume":"12 1","pages":"33"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11427632/pdf/","citationCount":"0","resultStr":"{\"title\":\"The German research consortium for the study of bipolar disorder (BipoLife): a quality assurance protocol for MR neuroimaging data.\",\"authors\":\"Christoph Vogelbacher, Jens Sommer, Miriam H A Bopp, Irina Falkenberg, Philipp S Ritter, Felix Bermpohl, Catherine Hindi Attar, Karolin E Einenkel, Oliver Gruber, Georg Juckel, Vera Flasbeck, Martin Hautzinger, Andrea Pfennig, Silke Matura, Andreas Reif, Dominik Grotegerd, Udo Dannlowski, Tilo Kircher, Michael Bauer, Andreas Jansen\",\"doi\":\"10.1186/s40345-024-00354-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The German multicenter research consortium BipoLife aims to investigate the mechanisms underlying bipolar disorders. It focuses in particular on people at high risk of developing the disorder and young patients in the early stages of the disease. Functional and structural magnetic resonance imaging (MRI) data was collected in all participating centers. The collection of neuroimaging data in a longitudinal, multicenter study requires the implementation of a comprehensive quality assurance (QA) protocol. Here, we outline this protocol and illustrate its application within the BipoLife consortium.</p><p><strong>Methods: </strong>The QA protocol consisted of (1) a training of participating research staff, (2) regular phantom measurements to evaluate the MR scanner performance and its temporal stability across the course of the study, and (3) the assessment of the quality of human MRI data by evaluating a variety of image metrics (e.g., signal-to-noise ratio, ghosting level). In this article, we will provide an overview on these QA procedures and show exemplarily the influence of its application on the results of standard neuroimaging analysis pipelines.</p><p><strong>Discussion: </strong>The QA protocol helped to characterize the various MR scanners, to record their performance over the course of the study and to detect possible malfunctions at an early stage. It also assessed the quality of the human MRI data systematically to characterize its influence on various analyses. Furthermore, by setting up and publishing this protocol, we define standards that must be considered when analyzing data from the BipoLife consortium. It further promotes a systematic evaluation of data quality and a definition of subject inclusion criteria. In the long term, it will help to increase the chance of achieving clinically relevant results.</p>\",\"PeriodicalId\":13944,\"journal\":{\"name\":\"International Journal of Bipolar Disorders\",\"volume\":\"12 1\",\"pages\":\"33\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11427632/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Bipolar Disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40345-024-00354-7\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PSYCHIATRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Bipolar Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40345-024-00354-7","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PSYCHIATRY","Score":null,"Total":0}
引用次数: 0

摘要

背景:德国多中心研究联盟 BipoLife 旨在研究躁郁症的发病机制。它特别关注躁郁症的高危人群和处于疾病早期阶段的年轻患者。所有参与中心都收集了功能和结构磁共振成像(MRI)数据。在纵向多中心研究中收集神经成像数据需要实施全面的质量保证(QA)方案。在此,我们概述了这一方案,并说明了其在 BipoLife 联合体中的应用:质量保证方案包括:(1) 对参与研究的人员进行培训;(2) 定期进行模型测量,以评估 MR 扫描仪的性能及其在整个研究过程中的时间稳定性;(3) 通过评估各种图像指标(如信噪比、重影水平)来评估人体 MRI 数据的质量。在本文中,我们将概述这些质量保证程序,并举例说明其应用对标准神经成像分析管道结果的影响:质量保证协议有助于确定各种磁共振扫描仪的特性,记录它们在研究过程中的表现,并及早发现可能出现的故障。它还系统地评估了人体磁共振成像数据的质量,以确定其对各种分析的影响。此外,通过制定和发布该协议,我们定义了分析 BipoLife 联合体数据时必须考虑的标准。它进一步促进了对数据质量的系统评估和受试者纳入标准的定义。从长远来看,这将有助于增加获得临床相关结果的机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The German research consortium for the study of bipolar disorder (BipoLife): a quality assurance protocol for MR neuroimaging data.

Background: The German multicenter research consortium BipoLife aims to investigate the mechanisms underlying bipolar disorders. It focuses in particular on people at high risk of developing the disorder and young patients in the early stages of the disease. Functional and structural magnetic resonance imaging (MRI) data was collected in all participating centers. The collection of neuroimaging data in a longitudinal, multicenter study requires the implementation of a comprehensive quality assurance (QA) protocol. Here, we outline this protocol and illustrate its application within the BipoLife consortium.

Methods: The QA protocol consisted of (1) a training of participating research staff, (2) regular phantom measurements to evaluate the MR scanner performance and its temporal stability across the course of the study, and (3) the assessment of the quality of human MRI data by evaluating a variety of image metrics (e.g., signal-to-noise ratio, ghosting level). In this article, we will provide an overview on these QA procedures and show exemplarily the influence of its application on the results of standard neuroimaging analysis pipelines.

Discussion: The QA protocol helped to characterize the various MR scanners, to record their performance over the course of the study and to detect possible malfunctions at an early stage. It also assessed the quality of the human MRI data systematically to characterize its influence on various analyses. Furthermore, by setting up and publishing this protocol, we define standards that must be considered when analyzing data from the BipoLife consortium. It further promotes a systematic evaluation of data quality and a definition of subject inclusion criteria. In the long term, it will help to increase the chance of achieving clinically relevant results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Bipolar Disorders
International Journal of Bipolar Disorders Medicine-Psychiatry and Mental Health
CiteScore
6.70
自引率
5.00%
发文量
26
审稿时长
13 weeks
期刊介绍: The International Journal of Bipolar Disorders is a peer-reviewed, open access online journal published under the SpringerOpen brand. It publishes contributions from the broad range of clinical, psychological and biological research in bipolar disorders. It is the official journal of the ECNP-ENBREC (European Network of Bipolar Research Expert Centres ) Bipolar Disorders Network, the International Group for the study of Lithium Treated Patients (IGSLi) and the Deutsche Gesellschaft für Bipolare Störungen (DGBS) and invites clinicians and researchers from around the globe to submit original research papers, short research communications, reviews, guidelines, case reports and letters to the editor that help to enhance understanding of bipolar disorders.
期刊最新文献
Correction: Perceived cognitive loss, symptomology, and psychological well-being with bipolar disorder. Prodromal symptoms of a first manic episode: a qualitative study to the perspectives of patients with bipolar disorder and their caregivers'. Aripiprazole once-monthly for the treatment of adult patients with earlier-stage bipolar I disorder: a post hoc analysis of data from a double-blind, placebo-controlled, 52-week randomized withdrawal trial. Correction: Effectiveness of ultra-long-term lithium treatment: relevant factors and case series. Relevance of red blood cell Lithium concentration in the management of Lithium-treated bipolar and unipolar disorders: a systematic narrative review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1