对有低血糖风险的遗传性代谢紊乱患者进行连续葡萄糖监测及营养影响。

IF 6.9 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Reviews in Endocrine & Metabolic Disorders Pub Date : 2024-10-01 DOI:10.1007/s11154-024-09903-y
Giorgia Gugelmo, Evelina Maines, Federico Boscari, Livia Lenzini, Gian Paolo Fadini, Alberto Burlina, Angelo Avogaro, Nicola Vitturi
{"title":"对有低血糖风险的遗传性代谢紊乱患者进行连续葡萄糖监测及营养影响。","authors":"Giorgia Gugelmo, Evelina Maines, Federico Boscari, Livia Lenzini, Gian Paolo Fadini, Alberto Burlina, Angelo Avogaro, Nicola Vitturi","doi":"10.1007/s11154-024-09903-y","DOIUrl":null,"url":null,"abstract":"<p><p>Managing Inherited Metabolic Disorders (IMDs) at risk for hypoglycemia, such as Glycogen Storage Diseases (GSDs), Hereditary Fructose Metabolism Disorders (HFMDs) and Congenital Hyperinsulinism (CH), poses challenges in dietary treatments and blood glucose monitoring. The effectiveness of Continuous Glucose Monitoring (CGM) remains a subject of ongoing debate, with IMD guidelines maintaining caution. Therefore, a systematic evaluation is needed to understand the potential benefits of CGM during dietary interventions. A systematic literature review was conducted in PubMed according to the PICOS model and PRISMA recommendations on studies published from January 01, 2003, up to October 15, 2023 (PROSPERO CRD42024497744). The risk of bias was assessed using NIH Quality Assessment Tools. Twenty-four studies in GSDs (n = 13), CH (n = 10), and HFMDs (n = 1) were analyzed. In GSDs, Real-time CGM (Rt-CGM) was associated with metabolic benefits during nutritional interventions, proving to be an accurate system for hypoglycemia detection although with some concerns about reliability. Rt-CGM in CH, primarily involving children, also showed potential benefits for glycemic control and metabolic stability with acceptable accuracy, although its use during dietary changes was limited. Few experiences on Flash Glucose Monitoring (FGM) were reported, with some concerns about reliability. Overall, the studies analyzed presented different designs, and their quality was predominantly fair or poor. Heterogeneity and limited consensus on reliability and glycemic targets underscore the need for prospective studies and future recommendations for the use of CGM in optimizing nutritional status and providing personalized dietary education in individuals with IMDs prone to hypoglycemia.</p>","PeriodicalId":21106,"journal":{"name":"Reviews in Endocrine & Metabolic Disorders","volume":" ","pages":"897-910"},"PeriodicalIF":6.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11470883/pdf/","citationCount":"0","resultStr":"{\"title\":\"Continuous glucose monitoring in patients with inherited metabolic disorders at risk for Hypoglycemia and Nutritional implications.\",\"authors\":\"Giorgia Gugelmo, Evelina Maines, Federico Boscari, Livia Lenzini, Gian Paolo Fadini, Alberto Burlina, Angelo Avogaro, Nicola Vitturi\",\"doi\":\"10.1007/s11154-024-09903-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Managing Inherited Metabolic Disorders (IMDs) at risk for hypoglycemia, such as Glycogen Storage Diseases (GSDs), Hereditary Fructose Metabolism Disorders (HFMDs) and Congenital Hyperinsulinism (CH), poses challenges in dietary treatments and blood glucose monitoring. The effectiveness of Continuous Glucose Monitoring (CGM) remains a subject of ongoing debate, with IMD guidelines maintaining caution. Therefore, a systematic evaluation is needed to understand the potential benefits of CGM during dietary interventions. A systematic literature review was conducted in PubMed according to the PICOS model and PRISMA recommendations on studies published from January 01, 2003, up to October 15, 2023 (PROSPERO CRD42024497744). The risk of bias was assessed using NIH Quality Assessment Tools. Twenty-four studies in GSDs (n = 13), CH (n = 10), and HFMDs (n = 1) were analyzed. In GSDs, Real-time CGM (Rt-CGM) was associated with metabolic benefits during nutritional interventions, proving to be an accurate system for hypoglycemia detection although with some concerns about reliability. Rt-CGM in CH, primarily involving children, also showed potential benefits for glycemic control and metabolic stability with acceptable accuracy, although its use during dietary changes was limited. Few experiences on Flash Glucose Monitoring (FGM) were reported, with some concerns about reliability. Overall, the studies analyzed presented different designs, and their quality was predominantly fair or poor. Heterogeneity and limited consensus on reliability and glycemic targets underscore the need for prospective studies and future recommendations for the use of CGM in optimizing nutritional status and providing personalized dietary education in individuals with IMDs prone to hypoglycemia.</p>\",\"PeriodicalId\":21106,\"journal\":{\"name\":\"Reviews in Endocrine & Metabolic Disorders\",\"volume\":\" \",\"pages\":\"897-910\"},\"PeriodicalIF\":6.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11470883/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reviews in Endocrine & Metabolic Disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11154-024-09903-y\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reviews in Endocrine & Metabolic Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11154-024-09903-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

管理有低血糖风险的遗传代谢性疾病(IMD),如糖原贮积症(GSD)、遗传性果糖代谢障碍(HFMD)和先天性胰岛素过多症(CH),给饮食治疗和血糖监测带来了挑战。连续血糖监测(CGM)的有效性仍是一个争论不休的话题,国际胰岛素发展协会(IMD)的指南仍持谨慎态度。因此,需要进行系统评估,以了解 CGM 在饮食干预期间的潜在益处。根据 PICOS 模型和 PRISMA 建议,在 PubMed 上对 2003 年 1 月 1 日至 2023 年 10 月 15 日发表的研究进行了系统性文献综述(PROSPERO CRD42024497744)。使用 NIH 质量评估工具对偏倚风险进行了评估。对 24 项关于 GSD(n = 13)、CH(n = 10)和 HFMD(n = 1)的研究进行了分析。在 GSDs 中,实时 CGM(Rt-CGM)与营养干预期间的新陈代谢益处相关,被证明是一种准确的低血糖检测系统,但在可靠性方面存在一些问题。Rt-CGM 在 CH(主要涉及儿童)中的应用也显示出对血糖控制和代谢稳定性的潜在益处,其准确性可以接受,但在饮食改变期间的应用有限。关于闪光血糖监测(FGM)的经验报道很少,可靠性方面存在一些问题。总体而言,所分析的研究采用了不同的设计,其质量大多一般或较差。在可靠性和血糖目标方面的异质性和有限的共识突出表明,有必要进行前瞻性研究,并在未来就 CGM 的使用提出建议,以优化营养状况,并为容易发生低血糖的 IMD 患者提供个性化饮食教育。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous glucose monitoring in patients with inherited metabolic disorders at risk for Hypoglycemia and Nutritional implications.

Managing Inherited Metabolic Disorders (IMDs) at risk for hypoglycemia, such as Glycogen Storage Diseases (GSDs), Hereditary Fructose Metabolism Disorders (HFMDs) and Congenital Hyperinsulinism (CH), poses challenges in dietary treatments and blood glucose monitoring. The effectiveness of Continuous Glucose Monitoring (CGM) remains a subject of ongoing debate, with IMD guidelines maintaining caution. Therefore, a systematic evaluation is needed to understand the potential benefits of CGM during dietary interventions. A systematic literature review was conducted in PubMed according to the PICOS model and PRISMA recommendations on studies published from January 01, 2003, up to October 15, 2023 (PROSPERO CRD42024497744). The risk of bias was assessed using NIH Quality Assessment Tools. Twenty-four studies in GSDs (n = 13), CH (n = 10), and HFMDs (n = 1) were analyzed. In GSDs, Real-time CGM (Rt-CGM) was associated with metabolic benefits during nutritional interventions, proving to be an accurate system for hypoglycemia detection although with some concerns about reliability. Rt-CGM in CH, primarily involving children, also showed potential benefits for glycemic control and metabolic stability with acceptable accuracy, although its use during dietary changes was limited. Few experiences on Flash Glucose Monitoring (FGM) were reported, with some concerns about reliability. Overall, the studies analyzed presented different designs, and their quality was predominantly fair or poor. Heterogeneity and limited consensus on reliability and glycemic targets underscore the need for prospective studies and future recommendations for the use of CGM in optimizing nutritional status and providing personalized dietary education in individuals with IMDs prone to hypoglycemia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Reviews in Endocrine & Metabolic Disorders
Reviews in Endocrine & Metabolic Disorders 医学-内分泌学与代谢
CiteScore
14.70
自引率
1.20%
发文量
75
审稿时长
>12 weeks
期刊介绍: Reviews in Endocrine and Metabolic Disorders is an international journal dedicated to the field of endocrinology and metabolism. It aims to provide the latest advancements in this rapidly advancing field to students, clinicians, and researchers. Unlike other journals, each quarterly issue of this review journal focuses on a specific topic and features ten to twelve articles written by world leaders in the field. These articles provide brief overviews of the latest developments, offering insights into both the basic aspects of the disease and its clinical implications. This format allows individuals in all areas of the field, including students, academic clinicians, and practicing clinicians, to understand the disease process and apply their knowledge to their specific areas of interest. The journal also includes selected readings and other essential references to encourage further in-depth exploration of specific topics.
期刊最新文献
Association of maternal blood metabolomics and gestational diabetes mellitus risk: a systematic review and meta-analysis. Correction: Real-world evidence of effectiveness and safety of pasireotide in the treatment of acromegaly: a systematic review and meta-analysis. The development of growth hormone-releasing hormone analogs: Therapeutic advances in cancer, regenerative medicine, and metabolic disorders. Central and peripheral regulation of the GH/IGF-1 axis: GHRH and beyond. Effects of GHRH and its analogues on the Vascular System.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1