Melvyn R. Lüssi, Gregor Fischer, Lorenzo Bertulli, Martin N. Stienen, Felix C. Stengel
{"title":"脊柱疾病患者使用定时起立行走测试自我测量客观功能障碍的可靠性。","authors":"Melvyn R. Lüssi, Gregor Fischer, Lorenzo Bertulli, Martin N. Stienen, Felix C. Stengel","doi":"10.1007/s00701-024-06293-7","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Accurate assessment of a patient's functional status is crucial for determining the need for treatment and evaluating outcomes. Objective functional impairment (OFI) measures, alongside patient-reported outcome measures (PROMs), have been proposed for spine diseases. The Timed-Up and Go (TUG) test, typically administered by healthcare professionals, is a well-studied OFI measure. This study investigates whether patient self-measurement of TUG is similarly reliable.</p><h3>Methods</h3><p>In a prospective, observational study, patients with spinal diseases underwent two TUG assessments: one measured by a healthcare professional and one self-measured by the patient. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) with a two-way random-effects model, considered excellent between 0.75 – 1.00. Paired t-tests directly compared both measurements. The impact of variables such as age, sex, disease type, symptom severity (via PROMs), comorbidities, and frailty on reliability was also analysed.</p><h3>Results</h3><p>Seventy-four patients were included, with a mean age of 62.9 years (SD 17.8); 29 (39.2%) were female. The majority (64.9%) were treated for degenerative disc disease. The lumbo-sacral region was most affected (71.6%), and 47.3% had previous surgeries. Patient self-measurement reliability was excellent (ICC 0.8740, <i>p</i> < 0.001), and the difference between healthcare professional (19.3 ± 9.4 s) and patient measurements (18.4 ± 9.7 s) was insignificant (<i>p</i> = 0.116). Interrater reliability remained high in patients > 65 years (ICC 0.8584, <i>p</i> < 0.001), patients with ASA grades 3&4 (ICC 0.7066, <i>p</i> < 0.001), patients considered frail (ICC 0.8799, <i>p</i> < 0.001), and in patients not using any walking aid (ICC 0.8012, <i>p</i> < 0.001). High symptom severity still showed strong reliability (ICC 0.8279, <i>p</i> < 0.001 for Oswestry Disability Index > 40; ICC 0.8607, <i>p</i> = 0.011 for Neck Disability Index > 40).</p><h3>Conclusions</h3><p>Patients with spine diseases can reliably self-measure OFI using the TUG test. The interrater reliability between self-measurements and those by healthcare professionals was excellent across all conditions. These findings could optimize patient assessments, especially in resource-limited settings.</p></div>","PeriodicalId":7370,"journal":{"name":"Acta Neurochirurgica","volume":"166 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of self-measured objective functional impairment using the timed up and go test in patients with diseases of the spine\",\"authors\":\"Melvyn R. Lüssi, Gregor Fischer, Lorenzo Bertulli, Martin N. Stienen, Felix C. Stengel\",\"doi\":\"10.1007/s00701-024-06293-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Accurate assessment of a patient's functional status is crucial for determining the need for treatment and evaluating outcomes. Objective functional impairment (OFI) measures, alongside patient-reported outcome measures (PROMs), have been proposed for spine diseases. The Timed-Up and Go (TUG) test, typically administered by healthcare professionals, is a well-studied OFI measure. This study investigates whether patient self-measurement of TUG is similarly reliable.</p><h3>Methods</h3><p>In a prospective, observational study, patients with spinal diseases underwent two TUG assessments: one measured by a healthcare professional and one self-measured by the patient. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) with a two-way random-effects model, considered excellent between 0.75 – 1.00. Paired t-tests directly compared both measurements. The impact of variables such as age, sex, disease type, symptom severity (via PROMs), comorbidities, and frailty on reliability was also analysed.</p><h3>Results</h3><p>Seventy-four patients were included, with a mean age of 62.9 years (SD 17.8); 29 (39.2%) were female. The majority (64.9%) were treated for degenerative disc disease. The lumbo-sacral region was most affected (71.6%), and 47.3% had previous surgeries. Patient self-measurement reliability was excellent (ICC 0.8740, <i>p</i> < 0.001), and the difference between healthcare professional (19.3 ± 9.4 s) and patient measurements (18.4 ± 9.7 s) was insignificant (<i>p</i> = 0.116). Interrater reliability remained high in patients > 65 years (ICC 0.8584, <i>p</i> < 0.001), patients with ASA grades 3&4 (ICC 0.7066, <i>p</i> < 0.001), patients considered frail (ICC 0.8799, <i>p</i> < 0.001), and in patients not using any walking aid (ICC 0.8012, <i>p</i> < 0.001). High symptom severity still showed strong reliability (ICC 0.8279, <i>p</i> < 0.001 for Oswestry Disability Index > 40; ICC 0.8607, <i>p</i> = 0.011 for Neck Disability Index > 40).</p><h3>Conclusions</h3><p>Patients with spine diseases can reliably self-measure OFI using the TUG test. The interrater reliability between self-measurements and those by healthcare professionals was excellent across all conditions. These findings could optimize patient assessments, especially in resource-limited settings.</p></div>\",\"PeriodicalId\":7370,\"journal\":{\"name\":\"Acta Neurochirurgica\",\"volume\":\"166 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Neurochirurgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00701-024-06293-7\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Neurochirurgica","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00701-024-06293-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Reliability of self-measured objective functional impairment using the timed up and go test in patients with diseases of the spine
Background
Accurate assessment of a patient's functional status is crucial for determining the need for treatment and evaluating outcomes. Objective functional impairment (OFI) measures, alongside patient-reported outcome measures (PROMs), have been proposed for spine diseases. The Timed-Up and Go (TUG) test, typically administered by healthcare professionals, is a well-studied OFI measure. This study investigates whether patient self-measurement of TUG is similarly reliable.
Methods
In a prospective, observational study, patients with spinal diseases underwent two TUG assessments: one measured by a healthcare professional and one self-measured by the patient. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) with a two-way random-effects model, considered excellent between 0.75 – 1.00. Paired t-tests directly compared both measurements. The impact of variables such as age, sex, disease type, symptom severity (via PROMs), comorbidities, and frailty on reliability was also analysed.
Results
Seventy-four patients were included, with a mean age of 62.9 years (SD 17.8); 29 (39.2%) were female. The majority (64.9%) were treated for degenerative disc disease. The lumbo-sacral region was most affected (71.6%), and 47.3% had previous surgeries. Patient self-measurement reliability was excellent (ICC 0.8740, p < 0.001), and the difference between healthcare professional (19.3 ± 9.4 s) and patient measurements (18.4 ± 9.7 s) was insignificant (p = 0.116). Interrater reliability remained high in patients > 65 years (ICC 0.8584, p < 0.001), patients with ASA grades 3&4 (ICC 0.7066, p < 0.001), patients considered frail (ICC 0.8799, p < 0.001), and in patients not using any walking aid (ICC 0.8012, p < 0.001). High symptom severity still showed strong reliability (ICC 0.8279, p < 0.001 for Oswestry Disability Index > 40; ICC 0.8607, p = 0.011 for Neck Disability Index > 40).
Conclusions
Patients with spine diseases can reliably self-measure OFI using the TUG test. The interrater reliability between self-measurements and those by healthcare professionals was excellent across all conditions. These findings could optimize patient assessments, especially in resource-limited settings.
期刊介绍:
The journal "Acta Neurochirurgica" publishes only original papers useful both to research and clinical work. Papers should deal with clinical neurosurgery - diagnosis and diagnostic techniques, operative surgery and results, postoperative treatment - or with research work in neuroscience if the underlying questions or the results are of neurosurgical interest. Reports on congresses are given in brief accounts. As official organ of the European Association of Neurosurgical Societies the journal publishes all announcements of the E.A.N.S. and reports on the activities of its member societies. Only contributions written in English will be accepted.