{"title":"用两条平行导管重建外伤性胫神经缺损:病例报告。","authors":"Hiroyuki Shirakura, Atsuhiko Iwao, Noriko Ikari, Rina Iida, Keita Kobashi, Shoko Ashizuka, Akihito Higashi, Yuki Moriuchi, Hiroto Saijo, Kazuya Kashiyama, Katsumi Tanaka","doi":"10.1080/23320885.2024.2407340","DOIUrl":null,"url":null,"abstract":"<p><p>We herein report a case of traumatic tibial nerve defect involving the ankle joint. A 16-mm-long defect was observed in a 5-mm-diameter tibial nerve. Two 3-mm-inner-diameter PGA-collagen tubes were transferred to the bifurcated tibial nerve. Satisfactory recovery was achieved at 3 year and 9 months postoperatively.</p>","PeriodicalId":42421,"journal":{"name":"Case Reports in Plastic Surgery and Hand Surgery","volume":"11 1","pages":"2407340"},"PeriodicalIF":0.4000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443561/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reconstruction of traumatic tibial nerve defect with two parallel conduit strands: a case report.\",\"authors\":\"Hiroyuki Shirakura, Atsuhiko Iwao, Noriko Ikari, Rina Iida, Keita Kobashi, Shoko Ashizuka, Akihito Higashi, Yuki Moriuchi, Hiroto Saijo, Kazuya Kashiyama, Katsumi Tanaka\",\"doi\":\"10.1080/23320885.2024.2407340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We herein report a case of traumatic tibial nerve defect involving the ankle joint. A 16-mm-long defect was observed in a 5-mm-diameter tibial nerve. Two 3-mm-inner-diameter PGA-collagen tubes were transferred to the bifurcated tibial nerve. Satisfactory recovery was achieved at 3 year and 9 months postoperatively.</p>\",\"PeriodicalId\":42421,\"journal\":{\"name\":\"Case Reports in Plastic Surgery and Hand Surgery\",\"volume\":\"11 1\",\"pages\":\"2407340\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443561/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Reports in Plastic Surgery and Hand Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/23320885.2024.2407340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Plastic Surgery and Hand Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/23320885.2024.2407340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
Reconstruction of traumatic tibial nerve defect with two parallel conduit strands: a case report.
We herein report a case of traumatic tibial nerve defect involving the ankle joint. A 16-mm-long defect was observed in a 5-mm-diameter tibial nerve. Two 3-mm-inner-diameter PGA-collagen tubes were transferred to the bifurcated tibial nerve. Satisfactory recovery was achieved at 3 year and 9 months postoperatively.