在肺部肿瘤立体定向消融放射治疗中使用持续气道正压优化靶点和膈肌配置,并获得剂量学优势。

Radiation oncology journal Pub Date : 2024-09-01 Epub Date: 2024-09-20 DOI:10.3857/roj.2024.00101
Jung Bin Park, Joo Ho Lee, Ji Hyun Chang, Jaeman Son, Seho Kwon, Su Yun Choi, Hyun-Woo Shin, Tosol Yu, Hak Jae Kim
{"title":"在肺部肿瘤立体定向消融放射治疗中使用持续气道正压优化靶点和膈肌配置,并获得剂量学优势。","authors":"Jung Bin Park, Joo Ho Lee, Ji Hyun Chang, Jaeman Son, Seho Kwon, Su Yun Choi, Hyun-Woo Shin, Tosol Yu, Hak Jae Kim","doi":"10.3857/roj.2024.00101","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the impact of facilitating target delineation of continuous positive airway pressure (CPAP) in patients undergoing stereotactic ablative radiation therapy (SABR) for lung tumors by lung expansion and respiratory motion management.</p><p><strong>Materials and methods: </strong>We performed a prospective single-institutional trial of patients who were diagnosed with either primary lung cancer or lung metastases and received SABR with a dose of 40 to 60 Gy in 4 fractions. Four-dimensional computed tomography simulations were conducted for each patient: once without CPAP and again with CPAP.</p><p><strong>Results: </strong>Thirty-two patients with 39 tumors were analyzed, after the withdrawal of five patients due to discomfort. For 26 tumors separated from the diaphragm, CPAP significantly increased the superoinferior distance between the tumor and the diaphragm (5.96 cm vs. 8.06 cm; p < 0.001). For 13 tumors located adjacent to the diaphragm, CPAP decreased the overlap of planning target volume (PTV) with the diaphragm significantly (6.32 cm3 vs. 4.09 cm3; p = 0.002). PTV showed a significant reduction with CPAP (25.06 cm3 vs. 22.52 cm3, p = 0.017). In dosimetric analyses, CPAP expanded lung volume by 58.4% with a significant reduction in mean dose and V5 to V40. No more than grade 2 adverse events were reported.</p><p><strong>Conclusion: </strong>This trial demonstrated significant improvement of CPAP in target delineation uncertainties for lung SABR, with dosimetric benefits, a favorable safety profile and tolerability. Further investigation is warranted to explore the role of CPAP as a novel strategy for respiratory motion management.</p>","PeriodicalId":94184,"journal":{"name":"Radiation oncology journal","volume":"42 3","pages":"200-209"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11467486/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors.\",\"authors\":\"Jung Bin Park, Joo Ho Lee, Ji Hyun Chang, Jaeman Son, Seho Kwon, Su Yun Choi, Hyun-Woo Shin, Tosol Yu, Hak Jae Kim\",\"doi\":\"10.3857/roj.2024.00101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the impact of facilitating target delineation of continuous positive airway pressure (CPAP) in patients undergoing stereotactic ablative radiation therapy (SABR) for lung tumors by lung expansion and respiratory motion management.</p><p><strong>Materials and methods: </strong>We performed a prospective single-institutional trial of patients who were diagnosed with either primary lung cancer or lung metastases and received SABR with a dose of 40 to 60 Gy in 4 fractions. Four-dimensional computed tomography simulations were conducted for each patient: once without CPAP and again with CPAP.</p><p><strong>Results: </strong>Thirty-two patients with 39 tumors were analyzed, after the withdrawal of five patients due to discomfort. For 26 tumors separated from the diaphragm, CPAP significantly increased the superoinferior distance between the tumor and the diaphragm (5.96 cm vs. 8.06 cm; p < 0.001). For 13 tumors located adjacent to the diaphragm, CPAP decreased the overlap of planning target volume (PTV) with the diaphragm significantly (6.32 cm3 vs. 4.09 cm3; p = 0.002). PTV showed a significant reduction with CPAP (25.06 cm3 vs. 22.52 cm3, p = 0.017). In dosimetric analyses, CPAP expanded lung volume by 58.4% with a significant reduction in mean dose and V5 to V40. No more than grade 2 adverse events were reported.</p><p><strong>Conclusion: </strong>This trial demonstrated significant improvement of CPAP in target delineation uncertainties for lung SABR, with dosimetric benefits, a favorable safety profile and tolerability. Further investigation is warranted to explore the role of CPAP as a novel strategy for respiratory motion management.</p>\",\"PeriodicalId\":94184,\"journal\":{\"name\":\"Radiation oncology journal\",\"volume\":\"42 3\",\"pages\":\"200-209\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11467486/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation oncology journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3857/roj.2024.00101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation oncology journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3857/roj.2024.00101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估通过肺扩张和呼吸运动管理促进肺肿瘤立体定向消融放射治疗(SABR)患者持续气道正压(CPAP)靶点划定的影响:我们对确诊为原发性肺癌或肺转移的患者进行了一项前瞻性单机构试验,这些患者接受了剂量为 40-60 Gy 的 4 次分次立体定向消融放射治疗。对每位患者进行了四维计算机断层扫描模拟:一次不使用 CPAP,另一次使用 CPAP:对 32 名患者的 39 个肿瘤进行了分析,其中 5 名患者因不适而退出。对于与膈肌分离的 26 个肿瘤,CPAP 可显著增加肿瘤与膈肌之间的上下端距离(5.96 厘米对 8.06 厘米;P < 0.001)。对于邻近膈肌的 13 个肿瘤,CPAP 可明显减少规划目标容积 (PTV) 与膈肌的重叠(6.32 立方厘米对 4.09 立方厘米;P = 0.002)。CPAP 可显著减少 PTV(25.06 立方厘米对 22.52 立方厘米,p = 0.017)。在剂量分析中,CPAP 使肺容积扩大了 58.4%,平均剂量和 V5 至 V40 显著减少。没有超过 2 级的不良反应报告:这项试验表明,CPAP 能明显改善肺部 SABR 的目标划定不确定性,同时具有剂量学优势、良好的安全性和耐受性。有必要进一步研究 CPAP 作为呼吸运动管理新策略的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors.

Purpose: This study aimed to evaluate the impact of facilitating target delineation of continuous positive airway pressure (CPAP) in patients undergoing stereotactic ablative radiation therapy (SABR) for lung tumors by lung expansion and respiratory motion management.

Materials and methods: We performed a prospective single-institutional trial of patients who were diagnosed with either primary lung cancer or lung metastases and received SABR with a dose of 40 to 60 Gy in 4 fractions. Four-dimensional computed tomography simulations were conducted for each patient: once without CPAP and again with CPAP.

Results: Thirty-two patients with 39 tumors were analyzed, after the withdrawal of five patients due to discomfort. For 26 tumors separated from the diaphragm, CPAP significantly increased the superoinferior distance between the tumor and the diaphragm (5.96 cm vs. 8.06 cm; p < 0.001). For 13 tumors located adjacent to the diaphragm, CPAP decreased the overlap of planning target volume (PTV) with the diaphragm significantly (6.32 cm3 vs. 4.09 cm3; p = 0.002). PTV showed a significant reduction with CPAP (25.06 cm3 vs. 22.52 cm3, p = 0.017). In dosimetric analyses, CPAP expanded lung volume by 58.4% with a significant reduction in mean dose and V5 to V40. No more than grade 2 adverse events were reported.

Conclusion: This trial demonstrated significant improvement of CPAP in target delineation uncertainties for lung SABR, with dosimetric benefits, a favorable safety profile and tolerability. Further investigation is warranted to explore the role of CPAP as a novel strategy for respiratory motion management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
0
期刊最新文献
Advancing radiation therapy through smartwatch technology to monitor anxiety. Could neoadjuvant radiation dose escalation increase tumor response and recurrence-free survival in patients with locally advanced rectal cancer? Long-term treatment of metastatic adenoid cystic carcinoma with sequential brachytherapy and stereotactic body radiotherapy. Oncological outcomes in patients with residual triple-negative breast cancer after preoperative chemotherapy. Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1