{"title":"适应模式及其与错配消极性的关联:脑电图(EEG)研究与受控期望。","authors":"Brian W. L. Wong, Shuting Huo, Urs Maurer","doi":"10.1111/ejn.16546","DOIUrl":null,"url":null,"abstract":"<p>Adaptation refers to the decreased neural response that occurs after repeated exposure to a stimulus. While many electroencephalogram (EEG) studies have investigated adaptation by using either single or multiple repetitions, the adaptation patterns under controlled expectations manifested in the two main auditory components, N1 and P2, are still largely unknown. Additionally, although multiple repetitions are commonly used in mismatch negativity (MMN) experiments, it is unclear how adaptation at different time windows contributes to this phenomenon. In this study, we conducted an EEG experiment with 37 healthy adults using a random stimulus arrangement and extended tone sequences to control expectations. We tracked the amplitudes of the N1 and P2 components across the first 10 tones to examine adaptation patterns. Our findings revealed an L-shaped adaptation pattern characterised by a significant decrease in N1 amplitude after the first repetition (N1 initial adaptation), followed by a continuous, linear increase in P2 amplitude after the first repetition (P2 subsequent adaptation), possibly indicating model adjustment. Regression analysis demonstrated that the peak amplitudes of both the N1 initial adaptation and the P2 subsequent adaptation significantly accounted for variance in MMN amplitude. These results suggest distinct adaptation patterns for multiple repetitions across different components and indicate that the MMN reflects a combination of two processes: the initial adaptation in the N1 and a continuous model adjustment effect in the P2. Understanding these processes separately could have implications for models of cognitive processing and clinical disorders.</p>","PeriodicalId":11993,"journal":{"name":"European Journal of Neuroscience","volume":"60 9","pages":"6312-6329"},"PeriodicalIF":2.7000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ejn.16546","citationCount":"0","resultStr":"{\"title\":\"Adaptation patterns and their associations with mismatch negativity: An electroencephalogram (EEG) study with controlled expectations\",\"authors\":\"Brian W. L. Wong, Shuting Huo, Urs Maurer\",\"doi\":\"10.1111/ejn.16546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Adaptation refers to the decreased neural response that occurs after repeated exposure to a stimulus. While many electroencephalogram (EEG) studies have investigated adaptation by using either single or multiple repetitions, the adaptation patterns under controlled expectations manifested in the two main auditory components, N1 and P2, are still largely unknown. Additionally, although multiple repetitions are commonly used in mismatch negativity (MMN) experiments, it is unclear how adaptation at different time windows contributes to this phenomenon. In this study, we conducted an EEG experiment with 37 healthy adults using a random stimulus arrangement and extended tone sequences to control expectations. We tracked the amplitudes of the N1 and P2 components across the first 10 tones to examine adaptation patterns. Our findings revealed an L-shaped adaptation pattern characterised by a significant decrease in N1 amplitude after the first repetition (N1 initial adaptation), followed by a continuous, linear increase in P2 amplitude after the first repetition (P2 subsequent adaptation), possibly indicating model adjustment. Regression analysis demonstrated that the peak amplitudes of both the N1 initial adaptation and the P2 subsequent adaptation significantly accounted for variance in MMN amplitude. These results suggest distinct adaptation patterns for multiple repetitions across different components and indicate that the MMN reflects a combination of two processes: the initial adaptation in the N1 and a continuous model adjustment effect in the P2. Understanding these processes separately could have implications for models of cognitive processing and clinical disorders.</p>\",\"PeriodicalId\":11993,\"journal\":{\"name\":\"European Journal of Neuroscience\",\"volume\":\"60 9\",\"pages\":\"6312-6329\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ejn.16546\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Neuroscience\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ejn.16546\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ejn.16546","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Adaptation patterns and their associations with mismatch negativity: An electroencephalogram (EEG) study with controlled expectations
Adaptation refers to the decreased neural response that occurs after repeated exposure to a stimulus. While many electroencephalogram (EEG) studies have investigated adaptation by using either single or multiple repetitions, the adaptation patterns under controlled expectations manifested in the two main auditory components, N1 and P2, are still largely unknown. Additionally, although multiple repetitions are commonly used in mismatch negativity (MMN) experiments, it is unclear how adaptation at different time windows contributes to this phenomenon. In this study, we conducted an EEG experiment with 37 healthy adults using a random stimulus arrangement and extended tone sequences to control expectations. We tracked the amplitudes of the N1 and P2 components across the first 10 tones to examine adaptation patterns. Our findings revealed an L-shaped adaptation pattern characterised by a significant decrease in N1 amplitude after the first repetition (N1 initial adaptation), followed by a continuous, linear increase in P2 amplitude after the first repetition (P2 subsequent adaptation), possibly indicating model adjustment. Regression analysis demonstrated that the peak amplitudes of both the N1 initial adaptation and the P2 subsequent adaptation significantly accounted for variance in MMN amplitude. These results suggest distinct adaptation patterns for multiple repetitions across different components and indicate that the MMN reflects a combination of two processes: the initial adaptation in the N1 and a continuous model adjustment effect in the P2. Understanding these processes separately could have implications for models of cognitive processing and clinical disorders.
期刊介绍:
EJN is the journal of FENS and supports the international neuroscientific community by publishing original high quality research articles and reviews in all fields of neuroscience. In addition, to engage with issues that are of interest to the science community, we also publish Editorials, Meetings Reports and Neuro-Opinions on topics that are of current interest in the fields of neuroscience research and training in science. We have recently established a series of ‘Profiles of Women in Neuroscience’. Our goal is to provide a vehicle for publications that further the understanding of the structure and function of the nervous system in both health and disease and to provide a vehicle to engage the neuroscience community. As the official journal of FENS, profits from the journal are re-invested in the neuroscientific community through the activities of FENS.