Lei Zheng, Yanhui Tong, Hamid Reza Karimi, Bixuan Huang
{"title":"基于同相滤波器的磁通量观测策略,用于无传感器控制 PMSM。","authors":"Lei Zheng, Yanhui Tong, Hamid Reza Karimi, Bixuan Huang","doi":"10.1016/j.isatra.2024.09.030","DOIUrl":null,"url":null,"abstract":"<p><p>Due to the complexity of determining the initial rotor flux and detecting errors, conventional rotor flux observation methods are easily affected by direct current (DC) components and harmonics. To address this issue, this paper proposes an in-phase filter (IPF)-based rotor flux observation strategy for sensorless control of permanent magnet synchronous machines (PMSMs). The core components of the IPF consist of a double second-order generalized integrator (DSOGI) and a phase angle compensation transfer function (PACTF). The DSOGI provides a accurate electrical angular frequency, while the PACTF implements a phase correction to the v<sub>q</sub><sup>'</sup> signals. By employing IPF structure, accurate observations for rotor flux, electronic speed, and rotor position are achieved, which can be effectively used in the sensorless control of PMSMs, eliminating the need for magnitude and phase compensations. Finally, the proposed observation strategy is applied to an experimental bench of a PMSM, and its effectiveness is illustrated by experimental results. From experimental results, it can be concluded that the IPF is significantly better than the LPF, and 5% more accurate than the observer based on cascade second-order generalized integral(CSOGI) overall.</p>","PeriodicalId":94059,"journal":{"name":"ISA transactions","volume":" ","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An in-phase filter-based flux observation strategy for sensorless control of PMSMs.\",\"authors\":\"Lei Zheng, Yanhui Tong, Hamid Reza Karimi, Bixuan Huang\",\"doi\":\"10.1016/j.isatra.2024.09.030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Due to the complexity of determining the initial rotor flux and detecting errors, conventional rotor flux observation methods are easily affected by direct current (DC) components and harmonics. To address this issue, this paper proposes an in-phase filter (IPF)-based rotor flux observation strategy for sensorless control of permanent magnet synchronous machines (PMSMs). The core components of the IPF consist of a double second-order generalized integrator (DSOGI) and a phase angle compensation transfer function (PACTF). The DSOGI provides a accurate electrical angular frequency, while the PACTF implements a phase correction to the v<sub>q</sub><sup>'</sup> signals. By employing IPF structure, accurate observations for rotor flux, electronic speed, and rotor position are achieved, which can be effectively used in the sensorless control of PMSMs, eliminating the need for magnitude and phase compensations. Finally, the proposed observation strategy is applied to an experimental bench of a PMSM, and its effectiveness is illustrated by experimental results. From experimental results, it can be concluded that the IPF is significantly better than the LPF, and 5% more accurate than the observer based on cascade second-order generalized integral(CSOGI) overall.</p>\",\"PeriodicalId\":94059,\"journal\":{\"name\":\"ISA transactions\",\"volume\":\" \",\"pages\":\"1-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISA transactions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.isatra.2024.09.030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISA transactions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.isatra.2024.09.030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An in-phase filter-based flux observation strategy for sensorless control of PMSMs.
Due to the complexity of determining the initial rotor flux and detecting errors, conventional rotor flux observation methods are easily affected by direct current (DC) components and harmonics. To address this issue, this paper proposes an in-phase filter (IPF)-based rotor flux observation strategy for sensorless control of permanent magnet synchronous machines (PMSMs). The core components of the IPF consist of a double second-order generalized integrator (DSOGI) and a phase angle compensation transfer function (PACTF). The DSOGI provides a accurate electrical angular frequency, while the PACTF implements a phase correction to the vq' signals. By employing IPF structure, accurate observations for rotor flux, electronic speed, and rotor position are achieved, which can be effectively used in the sensorless control of PMSMs, eliminating the need for magnitude and phase compensations. Finally, the proposed observation strategy is applied to an experimental bench of a PMSM, and its effectiveness is illustrated by experimental results. From experimental results, it can be concluded that the IPF is significantly better than the LPF, and 5% more accurate than the observer based on cascade second-order generalized integral(CSOGI) overall.