激光辅助下切牙根管充填清除术--一项显微 CT 研究。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-08-27 eCollection Date: 2024-07-01 DOI:10.4103/jispcd.jispcd_198_23
Violeta Dogandzhiyska, Irina Tsenova-Ilieva, Miriana Raykovska, Emilia Karova
{"title":"激光辅助下切牙根管充填清除术--一项显微 CT 研究。","authors":"Violeta Dogandzhiyska, Irina Tsenova-Ilieva, Miriana Raykovska, Emilia Karova","doi":"10.4103/jispcd.jispcd_198_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To compare the efficiency of root canal filling removal from oval-shaped root canals with high-energy Er:YAG laser and additional instrumentation with a rotary Ni-Ti XP-Endo Finisher R system.</p><p><strong>Materials and methods: </strong>The <i>in vitro</i> study was accomplished on 12 freshly extracted single-rooted mandibular incisors with one straight oval-shaped root canal, shaped with XP-Endo Shaper 30/.04 and obturated by using the warm vertical condensation technique subjected to further endodontic orthograde retreatment. Group 1: the first retreatment was carried out using a high-energy Er:YAG laser (<i>n</i> = 12). Group 2: the additional retreatment of the same specimens was performed with the XP-Endo Finisher-R system (<i>n</i> = 12). The effectiveness of the retreatment techniques was evaluated by a threefold micro-CT examination. The amount of the remaining root canal filling material was analyzed by Mann-Whitney <i>U</i> test and Friedman tests.</p><p><strong>Results: </strong>A significant decrease in the quantity of the root canal filling was found following the first and after the second retreatment, compared to the initial values in all examined sections (<i>P</i> < 0.001). Within groups, additional application of the Ni-Ti system resulted in no significant removal of the filling materials (<i>P</i> > 0.05).</p><p><strong>Conclusions: </strong>None of the systems resulted in complete root canal filling removal. Despite the improved results after the application of the supplementary retreatment protocol, none of the root canal walls were completely clean in the apical area. The high-energy Er:YAG laser and XP-Endo Finisher R rotary system can be successfully used in endodontic orthograde retreatment under relevant operating parameters.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11458087/pdf/","citationCount":"0","resultStr":"{\"title\":\"Laser-assisted Root Canal Filling Removal of Lower Incisors - A Micro-CT Study.\",\"authors\":\"Violeta Dogandzhiyska, Irina Tsenova-Ilieva, Miriana Raykovska, Emilia Karova\",\"doi\":\"10.4103/jispcd.jispcd_198_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To compare the efficiency of root canal filling removal from oval-shaped root canals with high-energy Er:YAG laser and additional instrumentation with a rotary Ni-Ti XP-Endo Finisher R system.</p><p><strong>Materials and methods: </strong>The <i>in vitro</i> study was accomplished on 12 freshly extracted single-rooted mandibular incisors with one straight oval-shaped root canal, shaped with XP-Endo Shaper 30/.04 and obturated by using the warm vertical condensation technique subjected to further endodontic orthograde retreatment. Group 1: the first retreatment was carried out using a high-energy Er:YAG laser (<i>n</i> = 12). Group 2: the additional retreatment of the same specimens was performed with the XP-Endo Finisher-R system (<i>n</i> = 12). The effectiveness of the retreatment techniques was evaluated by a threefold micro-CT examination. The amount of the remaining root canal filling material was analyzed by Mann-Whitney <i>U</i> test and Friedman tests.</p><p><strong>Results: </strong>A significant decrease in the quantity of the root canal filling was found following the first and after the second retreatment, compared to the initial values in all examined sections (<i>P</i> < 0.001). Within groups, additional application of the Ni-Ti system resulted in no significant removal of the filling materials (<i>P</i> > 0.05).</p><p><strong>Conclusions: </strong>None of the systems resulted in complete root canal filling removal. Despite the improved results after the application of the supplementary retreatment protocol, none of the root canal walls were completely clean in the apical area. The high-energy Er:YAG laser and XP-Endo Finisher R rotary system can be successfully used in endodontic orthograde retreatment under relevant operating parameters.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11458087/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jispcd.jispcd_198_23\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jispcd.jispcd_198_23","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较使用高能 Er:YAG 激光和旋转式 Ni-Ti XP-Endo Finisher R 系统辅助器械去除椭圆形根管填充物的效率:体外研究的对象是12颗刚拔出的单根下颌切牙,它们都有一个直的椭圆形根管,用XP-Endo Shaper 30/.04成型,并用温垂直冷凝技术进行闭合,然后再进行牙髓正交再治疗。第 1 组:使用高能 Er:YAG 激光进行第一次再治疗(n = 12)。第二组:使用 XP-Endo Finisher-R 系统对相同的标本进行额外的再治疗(n = 12)。再治疗技术的有效性通过三次显微 CT 检查进行评估。剩余根管填充材料的数量通过 Mann-Whitney U 检验和 Friedman 检验进行分析:结果:与所有检查切片的初始值相比,第一次和第二次再治疗后根管填充物的数量明显减少(P < 0.001)。在各组中,额外使用镍钛系统并没有明显去除充填材料(P > 0.05):结论:没有一种系统能完全清除根管充填物。结论:没有一种系统能完全清除根管充填物。尽管采用辅助再治疗方案后效果有所改善,但根尖区的根管壁都没有完全清除干净。在相关操作参数下,高能 Er:YAG 激光和 XP-Endo Finisher R 旋转系统可成功用于牙髓正交再治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Laser-assisted Root Canal Filling Removal of Lower Incisors - A Micro-CT Study.

Aim: To compare the efficiency of root canal filling removal from oval-shaped root canals with high-energy Er:YAG laser and additional instrumentation with a rotary Ni-Ti XP-Endo Finisher R system.

Materials and methods: The in vitro study was accomplished on 12 freshly extracted single-rooted mandibular incisors with one straight oval-shaped root canal, shaped with XP-Endo Shaper 30/.04 and obturated by using the warm vertical condensation technique subjected to further endodontic orthograde retreatment. Group 1: the first retreatment was carried out using a high-energy Er:YAG laser (n = 12). Group 2: the additional retreatment of the same specimens was performed with the XP-Endo Finisher-R system (n = 12). The effectiveness of the retreatment techniques was evaluated by a threefold micro-CT examination. The amount of the remaining root canal filling material was analyzed by Mann-Whitney U test and Friedman tests.

Results: A significant decrease in the quantity of the root canal filling was found following the first and after the second retreatment, compared to the initial values in all examined sections (P < 0.001). Within groups, additional application of the Ni-Ti system resulted in no significant removal of the filling materials (P > 0.05).

Conclusions: None of the systems resulted in complete root canal filling removal. Despite the improved results after the application of the supplementary retreatment protocol, none of the root canal walls were completely clean in the apical area. The high-energy Er:YAG laser and XP-Endo Finisher R rotary system can be successfully used in endodontic orthograde retreatment under relevant operating parameters.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Intentions to move abroad among medical students: a cross-sectional study to investigate determinants and opinions. Analysis of Medical Rehabilitation Needs of 2023 Kahramanmaraş Earthquake Victims: Adıyaman Example. Efficacy of whole body vibration on fascicle length and joint angle in children with hemiplegic cerebral palsy. The change process questionnaire (CPQ): A psychometric validation. Prevalence and predictors of hand hygiene compliance in clinical, surgical and intensive care unit wards: results of a second cross-sectional study at the Umberto I teaching hospital of Rome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1