计算机断层扫描得出的冠状动脉斑块体积测量的扫描间再现性。

IF 5.5 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Computed Tomography Pub Date : 2024-11-01 DOI:10.1016/j.jcct.2024.09.009
Nadia Iraqi , Martin Bødtker Mortensen , Niels Peter Rønnow Sand , Martin Busk , Erik Lerkevang Grove , Damini Dey , Kamilla Bech Pedersen , Helle Kanstrup , Alexandra Uglebjerg Pedersen , Kristian Tækker Madsen MD , Erik Parner , Jesper Møller Jensen , Bjarne Linde Nørgaard
{"title":"计算机断层扫描得出的冠状动脉斑块体积测量的扫描间再现性。","authors":"Nadia Iraqi ,&nbsp;Martin Bødtker Mortensen ,&nbsp;Niels Peter Rønnow Sand ,&nbsp;Martin Busk ,&nbsp;Erik Lerkevang Grove ,&nbsp;Damini Dey ,&nbsp;Kamilla Bech Pedersen ,&nbsp;Helle Kanstrup ,&nbsp;Alexandra Uglebjerg Pedersen ,&nbsp;Kristian Tækker Madsen MD ,&nbsp;Erik Parner ,&nbsp;Jesper Møller Jensen ,&nbsp;Bjarne Linde Nørgaard","doi":"10.1016/j.jcct.2024.09.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Coronary computed tomography angiography (CCTA) enables detailed quantification and characterization of coronary atherosclerotic plaques, offering diagnostic and prognostic value. Interscan reproducibility studies on plaque volume measurements are limited. This study aims to assess the interscan reproducibility of coronary plaque quantification and the implications of clinical and technical characteristics on interscan reproducibility.</div></div><div><h3>Methods</h3><div>CCTA was performed twice in 101 patients with known coronary artery disease at a 1-h interval. The scans were conducted using identical CCTA acquisition protocols. Coronary plaque volumes were quantified using a semi-automated software and performed on a per-lesion, per-vessel, and per-patient level.</div></div><div><h3>Results</h3><div>Median plaque volumes were comparable between the first and second CCTA scan. Interscan correlation was high for total plaque (TP), non-calcified plaque (NCP), and calcified plaque (CP) across all analyses (Pearson's coefficient 0.93–0.99), but lower for low-density non-calcified plaque (LD-NCP) volume measurements (Pearson's coefficient 0.74–0.77). Bland-Altman analyses demonstrated higher interscan agreement on a per-patient level compared to on per-vessel and per-lesion level. Interscan reproducibility on CP volumes was affected by CT image quality with narrower LoA in scans with the highest image quality score (p ​= ​0.003), or lowest image reconstructive iteration level (p ​&lt; ​0.001). Limits of agreement were significantly narrower for TP, NCP, and CP volumes in LAD-lesions and vessels compared to non-LAD lesions and vessels (p ​≤ ​0.001).</div></div><div><h3>Conclusion</h3><div>Overall reproducibility of repeated CCTA derived plaque measurements by a semi-automated software was modest, and was influenced by image quality, image reconstruction settings, and lesion location.</div></div>","PeriodicalId":49039,"journal":{"name":"Journal of Cardiovascular Computed Tomography","volume":"18 6","pages":"Pages 583-592"},"PeriodicalIF":5.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interscan reproducibility of computed tomography derived coronary plaque volume measurements\",\"authors\":\"Nadia Iraqi ,&nbsp;Martin Bødtker Mortensen ,&nbsp;Niels Peter Rønnow Sand ,&nbsp;Martin Busk ,&nbsp;Erik Lerkevang Grove ,&nbsp;Damini Dey ,&nbsp;Kamilla Bech Pedersen ,&nbsp;Helle Kanstrup ,&nbsp;Alexandra Uglebjerg Pedersen ,&nbsp;Kristian Tækker Madsen MD ,&nbsp;Erik Parner ,&nbsp;Jesper Møller Jensen ,&nbsp;Bjarne Linde Nørgaard\",\"doi\":\"10.1016/j.jcct.2024.09.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Coronary computed tomography angiography (CCTA) enables detailed quantification and characterization of coronary atherosclerotic plaques, offering diagnostic and prognostic value. Interscan reproducibility studies on plaque volume measurements are limited. This study aims to assess the interscan reproducibility of coronary plaque quantification and the implications of clinical and technical characteristics on interscan reproducibility.</div></div><div><h3>Methods</h3><div>CCTA was performed twice in 101 patients with known coronary artery disease at a 1-h interval. The scans were conducted using identical CCTA acquisition protocols. Coronary plaque volumes were quantified using a semi-automated software and performed on a per-lesion, per-vessel, and per-patient level.</div></div><div><h3>Results</h3><div>Median plaque volumes were comparable between the first and second CCTA scan. Interscan correlation was high for total plaque (TP), non-calcified plaque (NCP), and calcified plaque (CP) across all analyses (Pearson's coefficient 0.93–0.99), but lower for low-density non-calcified plaque (LD-NCP) volume measurements (Pearson's coefficient 0.74–0.77). Bland-Altman analyses demonstrated higher interscan agreement on a per-patient level compared to on per-vessel and per-lesion level. Interscan reproducibility on CP volumes was affected by CT image quality with narrower LoA in scans with the highest image quality score (p ​= ​0.003), or lowest image reconstructive iteration level (p ​&lt; ​0.001). Limits of agreement were significantly narrower for TP, NCP, and CP volumes in LAD-lesions and vessels compared to non-LAD lesions and vessels (p ​≤ ​0.001).</div></div><div><h3>Conclusion</h3><div>Overall reproducibility of repeated CCTA derived plaque measurements by a semi-automated software was modest, and was influenced by image quality, image reconstruction settings, and lesion location.</div></div>\",\"PeriodicalId\":49039,\"journal\":{\"name\":\"Journal of Cardiovascular Computed Tomography\",\"volume\":\"18 6\",\"pages\":\"Pages 583-592\"},\"PeriodicalIF\":5.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Computed Tomography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S193459252400443X\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Computed Tomography","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S193459252400443X","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:冠状动脉计算机断层扫描(CCTA)可对冠状动脉粥样硬化斑块进行详细量化和定性,具有诊断和预后价值。关于斑块体积测量的扫描间重现性研究非常有限。本研究旨在评估冠状动脉斑块量化的扫描间再现性,以及临床和技术特征对扫描间再现性的影响:方法:对 101 名已知患有冠状动脉疾病的患者进行了两次 CCTA 扫描,每次扫描间隔 1 小时。扫描采用相同的 CCTA 采集方案进行。使用半自动软件对冠状动脉斑块体积进行量化,并按每个病变、每个血管和每个患者进行量化:结果:第一次和第二次 CCTA 扫描的斑块体积中位数相当。在所有分析中,总斑块(TP)、非钙化斑块(NCP)和钙化斑块(CP)的扫描间相关性较高(皮尔逊系数 0.93-0.99),但低密度非钙化斑块(LD-NCP)体积测量的相关性较低(皮尔逊系数 0.74-0.77)。Bland-Altman分析表明,与每个血管和每个病灶水平相比,每个患者水平的扫描间一致性更高。CP 容量的扫描间再现性受 CT 图像质量的影响,图像质量得分最高(p = 0.003)或图像重建迭代水平最低(p 结论:CP 容量的扫描间再现性受 CT 图像质量的影响:半自动软件对重复 CCTA 得出的斑块测量结果的总体再现性一般,受图像质量、图像重建设置和病变位置的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Interscan reproducibility of computed tomography derived coronary plaque volume measurements

Background

Coronary computed tomography angiography (CCTA) enables detailed quantification and characterization of coronary atherosclerotic plaques, offering diagnostic and prognostic value. Interscan reproducibility studies on plaque volume measurements are limited. This study aims to assess the interscan reproducibility of coronary plaque quantification and the implications of clinical and technical characteristics on interscan reproducibility.

Methods

CCTA was performed twice in 101 patients with known coronary artery disease at a 1-h interval. The scans were conducted using identical CCTA acquisition protocols. Coronary plaque volumes were quantified using a semi-automated software and performed on a per-lesion, per-vessel, and per-patient level.

Results

Median plaque volumes were comparable between the first and second CCTA scan. Interscan correlation was high for total plaque (TP), non-calcified plaque (NCP), and calcified plaque (CP) across all analyses (Pearson's coefficient 0.93–0.99), but lower for low-density non-calcified plaque (LD-NCP) volume measurements (Pearson's coefficient 0.74–0.77). Bland-Altman analyses demonstrated higher interscan agreement on a per-patient level compared to on per-vessel and per-lesion level. Interscan reproducibility on CP volumes was affected by CT image quality with narrower LoA in scans with the highest image quality score (p ​= ​0.003), or lowest image reconstructive iteration level (p ​< ​0.001). Limits of agreement were significantly narrower for TP, NCP, and CP volumes in LAD-lesions and vessels compared to non-LAD lesions and vessels (p ​≤ ​0.001).

Conclusion

Overall reproducibility of repeated CCTA derived plaque measurements by a semi-automated software was modest, and was influenced by image quality, image reconstruction settings, and lesion location.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Cardiovascular Computed Tomography
Journal of Cardiovascular Computed Tomography CARDIAC & CARDIOVASCULAR SYSTEMS-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
7.50
自引率
14.80%
发文量
212
审稿时长
40 days
期刊介绍: The Journal of Cardiovascular Computed Tomography is a unique peer-review journal that integrates the entire international cardiovascular CT community including cardiologist and radiologists, from basic to clinical academic researchers, to private practitioners, engineers, allied professionals, industry, and trainees, all of whom are vital and interdependent members of our cardiovascular imaging community across the world. The goal of the journal is to advance the field of cardiovascular CT as the leading cardiovascular CT journal, attracting seminal work in the field with rapid and timely dissemination in electronic and print media.
期刊最新文献
Aortic dimensions in women with previous pre-eclampsia Photon-counting detector coronary CT angiography: Defining the optimal monoenergetic level for grading of calcified coronary stenosis Biventricular reverse-remodeling after transcatheter mitral valve replacement with the Tendyne™ system Computed tomography coronary angiography assessment of left main coronary artery stenosis severity Truncus arteriosus with double aortic arch: A rare case in an unrepaired pregnant patient
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1