基于零序有功功率调节的配电网跨国故障高阻抗馈线检测

IF 5 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC International Journal of Electrical Power & Energy Systems Pub Date : 2024-10-02 DOI:10.1016/j.ijepes.2024.110264
{"title":"基于零序有功功率调节的配电网跨国故障高阻抗馈线检测","authors":"","doi":"10.1016/j.ijepes.2024.110264","DOIUrl":null,"url":null,"abstract":"<div><div>The weak characteristics of high-impedance faults and the complex attributes of cross-country faults make faulty feeder detection of cross-country high-impedance faults difficult in medium-voltage networks. This paper deduces the zero-sequence equivalent circuit of cross-country faults through a three-sequence two-port network, analyzes the influence of grounding resistance on cross-country faults, and then explores the limitations of the traditional passive feeder detection methods. Moreover, this paper proposes a novel faulty feeder detection method for cross-country high-impedance faults based on zero-sequence active power regulation. First, based on the zero-sequence current varying characteristics under the regulation of zero-sequence voltage, construct a continuous adjustment region of zero-sequence voltage within the feeder insulation tolerance range. Next, based on the zero-sequence active power varying characteristics in each feeder, propose a discriminant formula for the zero-sequence active power fluctuation coefficient. Finally, adjusting zero-sequence voltage can actively amplify the differences in zero-sequence active power fluctuations between healthy feeders and faulty feeders and accurately select faulty feeders of cross-country high-impedance faults in medium-voltage networks. Various fault conditions are simulated in the PSCAD/EMTDC simulation and field test to verify the effectiveness of the proposed method. The proposed method can accurately identify all faulty feeders of cross-country high-impedance faults in the medium-voltage distribution network.</div></div>","PeriodicalId":50326,"journal":{"name":"International Journal of Electrical Power & Energy Systems","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-impedance faulty feeder detection for cross-country faults in distribution networks based on zero-sequence active power regulation\",\"authors\":\"\",\"doi\":\"10.1016/j.ijepes.2024.110264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The weak characteristics of high-impedance faults and the complex attributes of cross-country faults make faulty feeder detection of cross-country high-impedance faults difficult in medium-voltage networks. This paper deduces the zero-sequence equivalent circuit of cross-country faults through a three-sequence two-port network, analyzes the influence of grounding resistance on cross-country faults, and then explores the limitations of the traditional passive feeder detection methods. Moreover, this paper proposes a novel faulty feeder detection method for cross-country high-impedance faults based on zero-sequence active power regulation. First, based on the zero-sequence current varying characteristics under the regulation of zero-sequence voltage, construct a continuous adjustment region of zero-sequence voltage within the feeder insulation tolerance range. Next, based on the zero-sequence active power varying characteristics in each feeder, propose a discriminant formula for the zero-sequence active power fluctuation coefficient. Finally, adjusting zero-sequence voltage can actively amplify the differences in zero-sequence active power fluctuations between healthy feeders and faulty feeders and accurately select faulty feeders of cross-country high-impedance faults in medium-voltage networks. Various fault conditions are simulated in the PSCAD/EMTDC simulation and field test to verify the effectiveness of the proposed method. The proposed method can accurately identify all faulty feeders of cross-country high-impedance faults in the medium-voltage distribution network.</div></div>\",\"PeriodicalId\":50326,\"journal\":{\"name\":\"International Journal of Electrical Power & Energy Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical Power & Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S014206152400485X\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Power & Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S014206152400485X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

高阻抗故障的微弱特性和跨国故障的复杂属性使得中压网络中跨国高阻抗故障的馈线检测变得困难。本文通过三序两端口网络推导出跨国故障的零序等效电路,分析了接地电阻对跨国故障的影响,进而探讨了传统无源馈线检测方法的局限性。此外,本文还提出了一种基于零序有功功率调节的新型跨国高阻抗故障馈线检测方法。首先,基于零序电压调节下的零序电流变化特性,在馈线绝缘容差范围内构建零序电压连续调节区域。其次,根据各馈线的零序有功功率变化特性,提出零序有功功率波动系数的判别式。最后,调整零序电压可以主动放大健康馈线与故障馈线之间的零序有功功率波动差异,准确选择中压电网跨国高阻抗故障的故障馈线。在 PSCAD/EMTDC 仿真中模拟了各种故障条件,并进行了现场测试,以验证所提方法的有效性。所提出的方法能准确识别中压配电网中跨国高阻抗故障的所有故障馈线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-impedance faulty feeder detection for cross-country faults in distribution networks based on zero-sequence active power regulation
The weak characteristics of high-impedance faults and the complex attributes of cross-country faults make faulty feeder detection of cross-country high-impedance faults difficult in medium-voltage networks. This paper deduces the zero-sequence equivalent circuit of cross-country faults through a three-sequence two-port network, analyzes the influence of grounding resistance on cross-country faults, and then explores the limitations of the traditional passive feeder detection methods. Moreover, this paper proposes a novel faulty feeder detection method for cross-country high-impedance faults based on zero-sequence active power regulation. First, based on the zero-sequence current varying characteristics under the regulation of zero-sequence voltage, construct a continuous adjustment region of zero-sequence voltage within the feeder insulation tolerance range. Next, based on the zero-sequence active power varying characteristics in each feeder, propose a discriminant formula for the zero-sequence active power fluctuation coefficient. Finally, adjusting zero-sequence voltage can actively amplify the differences in zero-sequence active power fluctuations between healthy feeders and faulty feeders and accurately select faulty feeders of cross-country high-impedance faults in medium-voltage networks. Various fault conditions are simulated in the PSCAD/EMTDC simulation and field test to verify the effectiveness of the proposed method. The proposed method can accurately identify all faulty feeders of cross-country high-impedance faults in the medium-voltage distribution network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Electrical Power & Energy Systems
International Journal of Electrical Power & Energy Systems 工程技术-工程:电子与电气
CiteScore
12.10
自引率
17.30%
发文量
1022
审稿时长
51 days
期刊介绍: The journal covers theoretical developments in electrical power and energy systems and their applications. The coverage embraces: generation and network planning; reliability; long and short term operation; expert systems; neural networks; object oriented systems; system control centres; database and information systems; stock and parameter estimation; system security and adequacy; network theory, modelling and computation; small and large system dynamics; dynamic model identification; on-line control including load and switching control; protection; distribution systems; energy economics; impact of non-conventional systems; and man-machine interfaces. As well as original research papers, the journal publishes short contributions, book reviews and conference reports. All papers are peer-reviewed by at least two referees.
期刊最新文献
Low-frequency oscillations in AC railway traction power systems: Train input admittance calculation and stability analysis Real-time detection of insider attacks on substation automation systems using short length orthogonal wavelet filters and OPAL-RT An energy trade-off management strategy for hybrid ships based on event-triggered model predictive control Towards non-virtual inertia control of renewable energy for frequency regulation: Modeling, analysis and new control scheme Damping control in renewable-integrated power systems: A comparative analysis of PSS, POD-P, and POD-Q strategies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1