{"title":"区域电网的直流近区电压稳定约束可再生能源集成","authors":"Hailei He, Yantao Zhang, Xin Fang, Qinyong Zhou","doi":"10.1049/gtd2.13254","DOIUrl":null,"url":null,"abstract":"<p>With the increasing deployment of renewable energy resources, the scale of DC networks and renewable capacity continues to grow. System security is challenged by the decrease in inertia from traditional synchronous generators. In order to accommodate high-penetration renewable energy, voltage stability should be considered in the renewable energy integration planning. Herein, first, a voltage stability-constrained minimum startup index and algorithm for conventional thermal power plants are proposed. Then, based on time series production simulation, a renewable energy integration capacity analysis algorithm is designed considering voltage stability and peak shaving constraints. Finally, based on the boundary conditions of the “Fifteen-Five Plan”, the renewable energy capacity considering voltage stability and peak shaving constraints for Northwest and East China power grids are analysed to verify the effectiveness and engineering practicality of the proposed methodology. The results demonstrate that the proposed method can maintain the renewable energy integration goal outlined in the “Fifteen-Five Plan” while maintaining the voltage stability in these regions.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13254","citationCount":"0","resultStr":"{\"title\":\"DC near-area voltage stability constrained renewable energy integration for regional power grids\",\"authors\":\"Hailei He, Yantao Zhang, Xin Fang, Qinyong Zhou\",\"doi\":\"10.1049/gtd2.13254\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>With the increasing deployment of renewable energy resources, the scale of DC networks and renewable capacity continues to grow. System security is challenged by the decrease in inertia from traditional synchronous generators. In order to accommodate high-penetration renewable energy, voltage stability should be considered in the renewable energy integration planning. Herein, first, a voltage stability-constrained minimum startup index and algorithm for conventional thermal power plants are proposed. Then, based on time series production simulation, a renewable energy integration capacity analysis algorithm is designed considering voltage stability and peak shaving constraints. Finally, based on the boundary conditions of the “Fifteen-Five Plan”, the renewable energy capacity considering voltage stability and peak shaving constraints for Northwest and East China power grids are analysed to verify the effectiveness and engineering practicality of the proposed methodology. The results demonstrate that the proposed method can maintain the renewable energy integration goal outlined in the “Fifteen-Five Plan” while maintaining the voltage stability in these regions.</p>\",\"PeriodicalId\":13261,\"journal\":{\"name\":\"Iet Generation Transmission & Distribution\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13254\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Generation Transmission & Distribution\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13254\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13254","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
DC near-area voltage stability constrained renewable energy integration for regional power grids
With the increasing deployment of renewable energy resources, the scale of DC networks and renewable capacity continues to grow. System security is challenged by the decrease in inertia from traditional synchronous generators. In order to accommodate high-penetration renewable energy, voltage stability should be considered in the renewable energy integration planning. Herein, first, a voltage stability-constrained minimum startup index and algorithm for conventional thermal power plants are proposed. Then, based on time series production simulation, a renewable energy integration capacity analysis algorithm is designed considering voltage stability and peak shaving constraints. Finally, based on the boundary conditions of the “Fifteen-Five Plan”, the renewable energy capacity considering voltage stability and peak shaving constraints for Northwest and East China power grids are analysed to verify the effectiveness and engineering practicality of the proposed methodology. The results demonstrate that the proposed method can maintain the renewable energy integration goal outlined in the “Fifteen-Five Plan” while maintaining the voltage stability in these regions.
期刊介绍:
IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix.
The scope of IET Generation, Transmission & Distribution includes the following:
Design of transmission and distribution systems
Operation and control of power generation
Power system management, planning and economics
Power system operation, protection and control
Power system measurement and modelling
Computer applications and computational intelligence in power flexible AC or DC transmission systems
Special Issues. Current Call for papers:
Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf