双腔起搏器患者心房高频率发作的发生率和风险因素

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Arrhythmia Pub Date : 2024-09-03 DOI:10.1002/joa3.13143
Son Khac Le Nguyen MD, Dung Ngoc Kieu MD, Phuong Le Uyen Tran MD, Chuong Khac Thien Nguyen MD, Toan Quang Dang MD, Chieu Van Ly MD, Sy Van Hoang MD, PhD, Thuc Tri Nguyen MD, PhD
{"title":"双腔起搏器患者心房高频率发作的发生率和风险因素","authors":"Son Khac Le Nguyen MD,&nbsp;Dung Ngoc Kieu MD,&nbsp;Phuong Le Uyen Tran MD,&nbsp;Chuong Khac Thien Nguyen MD,&nbsp;Toan Quang Dang MD,&nbsp;Chieu Van Ly MD,&nbsp;Sy Van Hoang MD, PhD,&nbsp;Thuc Tri Nguyen MD, PhD","doi":"10.1002/joa3.13143","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background and Objectives</h3>\n \n <p>Cardiovascular implantable electronic devices can detect atrial high-rate episodes (AHREs). However, the predictors of clinically relevant AHREs have not been well identified.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This prospective study included 145 patients (median age 64.5 ± 16.4 years, 53.1% females) without atrial fibrillation (AF) from December 2020 to January 2022. AHREs were defined as a programmed atrial detection rate &gt;190 beats per minute. Cox regression analysis was used to identify the risk factors of AHREs.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>During 6 months of follow-up, AHREs occurred in 30.3% of patients. Multivariable Cox regression analysis showed factors related to development of AHREs including using anti-arrhythmic drugs (AAD) before implantation (Hazard ratio (HR) 7.71; 95% confidence interval [95% CI], 2.58–23.02, <i>p</i> &lt; .001), history of paroxysmal supraventricular tachycardia (PSVT; HR 2.45; [95% CI], 1.18–5.09, <i>p</i> = .016), the percentage of premature atrial contraction (PAC) on 24-h Holter electrocardiogram (ECG) monitoring (HR 1.008; [95% CI], 1.003–1.014, <i>p</i> = .003), and left ventricular global longitudinal strain (GLS-LV; HR 0.92;[95% CI], 0.84–0.99, <i>p</i> = .049).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>This study showed that a history of PSVT and using AAD, the percentage of PAC on 24-h Holter ECG monitoring, and GLS-LV were the independent predictors of new-onset AHREs.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 5","pages":"1158-1164"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13143","citationCount":"0","resultStr":"{\"title\":\"The incidence and risk factors of atrial high-rate episodes in patients with a dual-chamber pacemaker\",\"authors\":\"Son Khac Le Nguyen MD,&nbsp;Dung Ngoc Kieu MD,&nbsp;Phuong Le Uyen Tran MD,&nbsp;Chuong Khac Thien Nguyen MD,&nbsp;Toan Quang Dang MD,&nbsp;Chieu Van Ly MD,&nbsp;Sy Van Hoang MD, PhD,&nbsp;Thuc Tri Nguyen MD, PhD\",\"doi\":\"10.1002/joa3.13143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background and Objectives</h3>\\n \\n <p>Cardiovascular implantable electronic devices can detect atrial high-rate episodes (AHREs). However, the predictors of clinically relevant AHREs have not been well identified.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>This prospective study included 145 patients (median age 64.5 ± 16.4 years, 53.1% females) without atrial fibrillation (AF) from December 2020 to January 2022. AHREs were defined as a programmed atrial detection rate &gt;190 beats per minute. Cox regression analysis was used to identify the risk factors of AHREs.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>During 6 months of follow-up, AHREs occurred in 30.3% of patients. Multivariable Cox regression analysis showed factors related to development of AHREs including using anti-arrhythmic drugs (AAD) before implantation (Hazard ratio (HR) 7.71; 95% confidence interval [95% CI], 2.58–23.02, <i>p</i> &lt; .001), history of paroxysmal supraventricular tachycardia (PSVT; HR 2.45; [95% CI], 1.18–5.09, <i>p</i> = .016), the percentage of premature atrial contraction (PAC) on 24-h Holter electrocardiogram (ECG) monitoring (HR 1.008; [95% CI], 1.003–1.014, <i>p</i> = .003), and left ventricular global longitudinal strain (GLS-LV; HR 0.92;[95% CI], 0.84–0.99, <i>p</i> = .049).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>This study showed that a history of PSVT and using AAD, the percentage of PAC on 24-h Holter ECG monitoring, and GLS-LV were the independent predictors of new-onset AHREs.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"40 5\",\"pages\":\"1158-1164\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13143\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13143\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的 心血管植入式电子设备可检测心房高频率发作(AHRE)。然而,临床相关 AHRE 的预测因素尚未得到很好的确定。 方法 这项前瞻性研究纳入了 2020 年 12 月至 2022 年 1 月期间 145 名无心房颤动(AF)的患者(中位年龄为 64.5 ± 16.4 岁,53.1% 为女性)。AHRE定义为程序性心房检测率>190次/分钟。Cox回归分析用于确定AHREs的风险因素。 结果 在 6 个月的随访期间,30.3% 的患者发生了 AHRE。多变量 Cox 回归分析显示,与发生 AHREs 相关的因素包括植入前使用抗心律失常药物(AAD)(危险比 (HR) 7.71; 95% 置信区间 [95% CI], 2.58-23.02, p <.001)、阵发性室上性心动过速(PSVT;HR 2.45;[95% CI],1.18-5.09,p = .016)、24 小时 Holter 心电图(ECG)监测中房性早搏(PAC)的百分比(HR 1.008;[95% CI],1.003-1.014,p = .003)和左室整体纵向应变(GLS-LV;HR 0.92;[95% CI],0.84-0.99,p = .049)。 结论 本研究表明,PSVT 病史和使用 AAD、24 h Holter ECG 监测中 PAC 的百分比以及 GLS-LV 是新发 AHRE 的独立预测因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The incidence and risk factors of atrial high-rate episodes in patients with a dual-chamber pacemaker

Background and Objectives

Cardiovascular implantable electronic devices can detect atrial high-rate episodes (AHREs). However, the predictors of clinically relevant AHREs have not been well identified.

Methods

This prospective study included 145 patients (median age 64.5 ± 16.4 years, 53.1% females) without atrial fibrillation (AF) from December 2020 to January 2022. AHREs were defined as a programmed atrial detection rate >190 beats per minute. Cox regression analysis was used to identify the risk factors of AHREs.

Results

During 6 months of follow-up, AHREs occurred in 30.3% of patients. Multivariable Cox regression analysis showed factors related to development of AHREs including using anti-arrhythmic drugs (AAD) before implantation (Hazard ratio (HR) 7.71; 95% confidence interval [95% CI], 2.58–23.02, p < .001), history of paroxysmal supraventricular tachycardia (PSVT; HR 2.45; [95% CI], 1.18–5.09, p = .016), the percentage of premature atrial contraction (PAC) on 24-h Holter electrocardiogram (ECG) monitoring (HR 1.008; [95% CI], 1.003–1.014, p = .003), and left ventricular global longitudinal strain (GLS-LV; HR 0.92;[95% CI], 0.84–0.99, p = .049).

Conclusions

This study showed that a history of PSVT and using AAD, the percentage of PAC on 24-h Holter ECG monitoring, and GLS-LV were the independent predictors of new-onset AHREs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
期刊最新文献
Issue Information Dementia risk reduction between DOACs and VKAs in AF: A systematic review and meta-analysis Electro-anatomically confirmed sites of origin of ventricular tachycardia and premature ventricular contractions and occurrence of R wave in lead aVR: A proof of concept study The Japanese Catheter Ablation Registry (J-AB): Annual report in 2022 Slow left atrial conduction velocity in the anterior wall calculated by electroanatomic mapping predicts atrial fibrillation recurrence after catheter ablation—Systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1