基于间接手性配体交换色谱的富马酸替诺福韦阿拉非酰胺手性异构体的拆分和分离机制。

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-10-21 DOI:10.1039/d4ay01388c
Li Lin, Longchao Xie, Lingyi Huang, Liying Huang, Youjia Wu
{"title":"基于间接手性配体交换色谱的富马酸替诺福韦阿拉非酰胺手性异构体的拆分和分离机制。","authors":"Li Lin, Longchao Xie, Lingyi Huang, Liying Huang, Youjia Wu","doi":"10.1039/d4ay01388c","DOIUrl":null,"url":null,"abstract":"<p><p>The isolation and analysis of chiral isomers are critical parts of the drug development process to ensure effective and safe drug administration to patients. Indirect chiral ligand exchange chromatography (ICLEC) was developed to separate and determine tenofovir alafenamide fumarate (TAF) and its diastereoisomer GS-7339, with a hypothesized separation mechanism. The effect of using a chiral column <i>versus</i> a standard C18 column on the separation of the TAF chiral isomer mixture was investigated. Various factors in ICLEC, including ligand type, ligand ratio, mobile phase composition, and column temperature, were optimized. The separation of TAF and GS-7339 was successfully achieved by selecting L-phenylalanine as the chiral selective agent and Cu(II) as the central metal ion, using a C18 column as the analytic column and a mobile phase of 20 mM ammonium dihydrogen phosphate buffer (pH = 4.0)-acetonitrile (79 : 21, v/v). The corresponding linearity range for TAF and GS-7339 indicated a good correlation with <i>R</i><sup>2</sup> > 0.9960. The average recoveries of TAF and GS-7339 ranged from 98.2% to 106.9%. None of the eight manufacturers detected GS-7339, and the percentage of TAF-labeled amounts in the drugs ranged from 95.0% to 98.5%. TAF tablets from eight manufacturers were of satisfactory quality. The separation mechanism of TAF and GS-7339 by ICLEC is due to the different spatial configurations of the two ternary complexes formed by the two chiral isomers, leading to differences in their thermodynamic stability and retention behavior. The established ICLEC method is economical, simple, and flexible, providing an effective strategy for studying chiral drug separation and analysis.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Splitting and separation mechanism of tenofovir alafenamide fumarate chiral isomers based on indirect chiral ligand exchange chromatography.\",\"authors\":\"Li Lin, Longchao Xie, Lingyi Huang, Liying Huang, Youjia Wu\",\"doi\":\"10.1039/d4ay01388c\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The isolation and analysis of chiral isomers are critical parts of the drug development process to ensure effective and safe drug administration to patients. Indirect chiral ligand exchange chromatography (ICLEC) was developed to separate and determine tenofovir alafenamide fumarate (TAF) and its diastereoisomer GS-7339, with a hypothesized separation mechanism. The effect of using a chiral column <i>versus</i> a standard C18 column on the separation of the TAF chiral isomer mixture was investigated. Various factors in ICLEC, including ligand type, ligand ratio, mobile phase composition, and column temperature, were optimized. The separation of TAF and GS-7339 was successfully achieved by selecting L-phenylalanine as the chiral selective agent and Cu(II) as the central metal ion, using a C18 column as the analytic column and a mobile phase of 20 mM ammonium dihydrogen phosphate buffer (pH = 4.0)-acetonitrile (79 : 21, v/v). The corresponding linearity range for TAF and GS-7339 indicated a good correlation with <i>R</i><sup>2</sup> > 0.9960. The average recoveries of TAF and GS-7339 ranged from 98.2% to 106.9%. None of the eight manufacturers detected GS-7339, and the percentage of TAF-labeled amounts in the drugs ranged from 95.0% to 98.5%. TAF tablets from eight manufacturers were of satisfactory quality. The separation mechanism of TAF and GS-7339 by ICLEC is due to the different spatial configurations of the two ternary complexes formed by the two chiral isomers, leading to differences in their thermodynamic stability and retention behavior. The established ICLEC method is economical, simple, and flexible, providing an effective strategy for studying chiral drug separation and analysis.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4ay01388c\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01388c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Splitting and separation mechanism of tenofovir alafenamide fumarate chiral isomers based on indirect chiral ligand exchange chromatography.

The isolation and analysis of chiral isomers are critical parts of the drug development process to ensure effective and safe drug administration to patients. Indirect chiral ligand exchange chromatography (ICLEC) was developed to separate and determine tenofovir alafenamide fumarate (TAF) and its diastereoisomer GS-7339, with a hypothesized separation mechanism. The effect of using a chiral column versus a standard C18 column on the separation of the TAF chiral isomer mixture was investigated. Various factors in ICLEC, including ligand type, ligand ratio, mobile phase composition, and column temperature, were optimized. The separation of TAF and GS-7339 was successfully achieved by selecting L-phenylalanine as the chiral selective agent and Cu(II) as the central metal ion, using a C18 column as the analytic column and a mobile phase of 20 mM ammonium dihydrogen phosphate buffer (pH = 4.0)-acetonitrile (79 : 21, v/v). The corresponding linearity range for TAF and GS-7339 indicated a good correlation with R2 > 0.9960. The average recoveries of TAF and GS-7339 ranged from 98.2% to 106.9%. None of the eight manufacturers detected GS-7339, and the percentage of TAF-labeled amounts in the drugs ranged from 95.0% to 98.5%. TAF tablets from eight manufacturers were of satisfactory quality. The separation mechanism of TAF and GS-7339 by ICLEC is due to the different spatial configurations of the two ternary complexes formed by the two chiral isomers, leading to differences in their thermodynamic stability and retention behavior. The established ICLEC method is economical, simple, and flexible, providing an effective strategy for studying chiral drug separation and analysis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
Simultaneous analysis of depurinated nucleic acid stem-loop and free adenine for ricin toxicity assay by hydrophilic interaction liquid chromatography-high-resolution mass spectrometry (HILIC-HRMS). A chemiluminescent sensor based on CRISPR-HCR technology for the hypersensitive detection of Mycobacterium tuberculosis. A numerical platform for predicting the performance of paper-based analytical devices. A rapid evaluation method for the quality consistency assessment and spectrum-effect relationship study of Xiaohuoluo Pills developed based on combined spectral and chromatography technology. A simple turn-off fluorescent chemosensor based on a Schiff base structure for ultrafast and highly selective trace detection of Cu2+ ions in aqueous solutions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1