利用多核合成技术创建薄层低噪声图像以取代头部 CT 多图像序列的可行性。

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Acta radiologica Pub Date : 2024-11-01 Epub Date: 2024-10-17 DOI:10.1177/02841851241280365
Akitoshi Inoue, Felix E Diehn, Alex A Nagelschneider, Theodore J Passe, David R DeLone, Brandon J Nelson, Daniel G Gomez Cardona, Nathan R Huber, Andrew D Missert, Lifeng Yu, Matthew P Johnson, David R Holmes, Yong S Lee, Jamison E Thorne, Cynthia H McCollough, Joel G Fletcher
{"title":"利用多核合成技术创建薄层低噪声图像以取代头部 CT 多图像序列的可行性。","authors":"Akitoshi Inoue, Felix E Diehn, Alex A Nagelschneider, Theodore J Passe, David R DeLone, Brandon J Nelson, Daniel G Gomez Cardona, Nathan R Huber, Andrew D Missert, Lifeng Yu, Matthew P Johnson, David R Holmes, Yong S Lee, Jamison E Thorne, Cynthia H McCollough, Joel G Fletcher","doi":"10.1177/02841851241280365","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging.</p><p><strong>Purpose: </strong>To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit.</p><p><strong>Material and methods: </strong>In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0-100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: -0.10).</p><p><strong>Results: </strong>ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=-0.051-0.057]) and fractures (0.048 [95% CI=-0.050-0.145]) but not for intracranial findings alone (-0.024 [95% CI=-0.100-0.052]).</p><p><strong>Conclusion: </strong>Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"1411-1421"},"PeriodicalIF":1.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT.\",\"authors\":\"Akitoshi Inoue, Felix E Diehn, Alex A Nagelschneider, Theodore J Passe, David R DeLone, Brandon J Nelson, Daniel G Gomez Cardona, Nathan R Huber, Andrew D Missert, Lifeng Yu, Matthew P Johnson, David R Holmes, Yong S Lee, Jamison E Thorne, Cynthia H McCollough, Joel G Fletcher\",\"doi\":\"10.1177/02841851241280365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging.</p><p><strong>Purpose: </strong>To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit.</p><p><strong>Material and methods: </strong>In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0-100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: -0.10).</p><p><strong>Results: </strong>ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=-0.051-0.057]) and fractures (0.048 [95% CI=-0.050-0.145]) but not for intracranial findings alone (-0.024 [95% CI=-0.100-0.052]).</p><p><strong>Conclusion: </strong>Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.</p>\",\"PeriodicalId\":7143,\"journal\":{\"name\":\"Acta radiologica\",\"volume\":\" \",\"pages\":\"1411-1421\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02841851241280365\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241280365","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:目的:比较一组 ZIRCON 图像与两组使用传统 CT 头部和骨骼重建内核的常规临床图像的诊断性能,以诊断外伤或疑似急性神经功能缺损患者的颅内发现和骨折:共有 50 名患者在急诊室接受了有临床指征的头部 CT 检查(正常 15 例,异常 35 例)。一名非阅片神经放射科医生制定了参考标准。三位神经放射学专家对两组常规临床系列(头颅和骨核)和一组 ZIRCON 系列进行审查,检测颅内发现或骨折情况,并对可信度进行评分(0-100)。比较了灵敏度、特异性和杰克刀自由响应接收器操作特征(JAFROC)的优越性(FOM)(非劣效界限:-0.10):结果:ZIRCON 和传统图像在骨折(灵敏度:51.5% 对 54.5%;特异性:40.2% 对 34.2%)和颅内发现(灵敏度:88.2% 对 91.4%;特异性:77.2% 对 73.7%)方面表现相当。JAFROC FOM的估计差值显示,ZIRCON在急性病变(0.003 [95% CI=-0.051-0.057])和骨折(0.048 [95% CI=-0.050-0.145])方面没有劣势,但在颅内发现方面没有劣势(-0.024 [95% CI=-0.100-0.052]):结论:薄切片、低噪声和高空间分辨率图像可用于显示颅内发现和骨折,取代头颅 CT 中的多个图像系列,且性能相似。今后有必要对更多患者进行研究,并进一步开发算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT.

Background: SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging.

Purpose: To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit.

Material and methods: In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0-100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: -0.10).

Results: ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=-0.051-0.057]) and fractures (0.048 [95% CI=-0.050-0.145]) but not for intracranial findings alone (-0.024 [95% CI=-0.100-0.052]).

Conclusion: Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
期刊最新文献
A combined model integrating radiomics and deep learning based on multiparametric magnetic resonance imaging for classification of brain metastases. Anatomical insights into medial-sided talar dome osteochondral lesions: a comparative analysis of unilateral and bilateral cases and healthy controls using MRI measurements. Can smartphone cameras help with diagnostic adequacy in renal biopsy? Factors related to acute kidney injury after AngioJet rheolytic thrombectomy. MR defecography: comparison of HMO system measurement between supine and lateral decubitus patient position.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1