EuroFlow PIDOT 外部质量保证计划:加强罕见淋巴免疫缺陷的免疫分型实验室绩效评估。

IF 3.8 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Clinical chemistry and laboratory medicine Pub Date : 2024-10-21 DOI:10.1515/cclm-2024-0749
Jana Neirinck, Malicorne Buysse, Naděžda Brdickova, Martín Perez-Andres, Ciel De Vriendt, Tessa Kerre, Filomeen Haerynck, Xavier Bossuyt, Jacques J M van Dongen, Alberto Orfao, Mattias Hofmans, Carolien Bonroy, Tomas Kalina
{"title":"EuroFlow PIDOT 外部质量保证计划:加强罕见淋巴免疫缺陷的免疫分型实验室绩效评估。","authors":"Jana Neirinck, Malicorne Buysse, Naděžda Brdickova, Martín Perez-Andres, Ciel De Vriendt, Tessa Kerre, Filomeen Haerynck, Xavier Bossuyt, Jacques J M van Dongen, Alberto Orfao, Mattias Hofmans, Carolien Bonroy, Tomas Kalina","doi":"10.1515/cclm-2024-0749","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The development of External Quality Assessment Schemes (EQAS) for clinical flow cytometry (FCM) is challenging in the context of rare (immunological) diseases. Here, we introduce a novel EQAS monitoring the primary immunodeficiency Orientation Tube (PIDOT), developed by EuroFlow, in both a 'wet' and 'dry' format. This EQAS provides feedback on the quality of individual laboratories (i.e., accuracy, reproducibility and result interpretation), while eliminating the need for sample distribution.</p><p><strong>Methods: </strong>In the wet format, marker staining intensities (MedFIs) within landmark cell populations in PIDOT analysis performed on locally collected healthy control (HC) samples, were compared to EQAS targets. In the dry format, participants analyzed centrally distributed PIDOT flow cytometry data (n=10).</p><p><strong>Results: </strong>We report the results of six EQAS rounds across 20 laboratories in 11 countries. The wet format (212 HC samples) demonstrated consistent technical performance among laboratories (median %rCV on MedFIs=34.5 %; average failure rate 17.3 %) and showed improvement upon repeated participation. The dry format demonstrated effective proficiency of participants in cell count enumeration (range %rCVs 3.1-7.1 % for the major lymphoid subsets), and in identifying lymphoid abnormalities (79.3 % alignment with reference).</p><p><strong>Conclusions: </strong>The PIDOT-EQAS allows laboratories, adhering to the standardized EuroFlow approach, to monitor interlaboratory variations without the need for sample distribution, and provides them educational support to recognize rare clinically relevant immunophenotypic patterns of primary immunodeficiencies (PID). This EQAS contributes to quality improvement of PID diagnostics and can serve as an example for future flow cytometry EQAS in the context of rare diseases.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The EuroFlow PIDOT external quality assurance scheme: enhancing laboratory performance evaluation in immunophenotyping of rare lymphoid immunodeficiencies.\",\"authors\":\"Jana Neirinck, Malicorne Buysse, Naděžda Brdickova, Martín Perez-Andres, Ciel De Vriendt, Tessa Kerre, Filomeen Haerynck, Xavier Bossuyt, Jacques J M van Dongen, Alberto Orfao, Mattias Hofmans, Carolien Bonroy, Tomas Kalina\",\"doi\":\"10.1515/cclm-2024-0749\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The development of External Quality Assessment Schemes (EQAS) for clinical flow cytometry (FCM) is challenging in the context of rare (immunological) diseases. Here, we introduce a novel EQAS monitoring the primary immunodeficiency Orientation Tube (PIDOT), developed by EuroFlow, in both a 'wet' and 'dry' format. This EQAS provides feedback on the quality of individual laboratories (i.e., accuracy, reproducibility and result interpretation), while eliminating the need for sample distribution.</p><p><strong>Methods: </strong>In the wet format, marker staining intensities (MedFIs) within landmark cell populations in PIDOT analysis performed on locally collected healthy control (HC) samples, were compared to EQAS targets. In the dry format, participants analyzed centrally distributed PIDOT flow cytometry data (n=10).</p><p><strong>Results: </strong>We report the results of six EQAS rounds across 20 laboratories in 11 countries. The wet format (212 HC samples) demonstrated consistent technical performance among laboratories (median %rCV on MedFIs=34.5 %; average failure rate 17.3 %) and showed improvement upon repeated participation. The dry format demonstrated effective proficiency of participants in cell count enumeration (range %rCVs 3.1-7.1 % for the major lymphoid subsets), and in identifying lymphoid abnormalities (79.3 % alignment with reference).</p><p><strong>Conclusions: </strong>The PIDOT-EQAS allows laboratories, adhering to the standardized EuroFlow approach, to monitor interlaboratory variations without the need for sample distribution, and provides them educational support to recognize rare clinically relevant immunophenotypic patterns of primary immunodeficiencies (PID). This EQAS contributes to quality improvement of PID diagnostics and can serve as an example for future flow cytometry EQAS in the context of rare diseases.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2024-0749\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0749","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:在罕见(免疫)疾病的背景下,为临床流式细胞仪 (FCM) 制定外部质量评估计划 (EQAS) 是一项挑战。在此,我们以 "湿式 "和 "干式 "两种形式介绍了由 EuroFlow 开发的新型 EQAS(监测原发性免疫缺陷定向管 (PIDOT))。这种 EQAS 可对各个实验室的质量(即准确性、可重复性和结果解释)提供反馈,同时无需分发样本:方法:在湿法格式中,将对当地采集的健康对照(HC)样本进行的 PIDOT 分析中地标细胞群内的标记物染色强度(MedFIs)与 EQAS 目标进行比较。在干式方法中,参与者分析集中分布的 PIDOT 流式细胞仪数据(n=10):我们报告了 11 个国家 20 个实验室的六轮 EQAS 结果。湿式测试(212 份 HC 样本)显示各实验室的技术表现一致(MedFIs 的中位 %rCV=34.5 %;平均失败率为 17.3 %),并在重复参与后有所改善。干式方法显示,参与者在细胞计数计数(主要淋巴亚群的%rCV范围为3.1-7.1%)和淋巴异常鉴别(79.3%与参考值一致)方面的熟练程度很高:PIDOT-EQAS允许实验室采用标准化的EuroFlow方法监测实验室间的差异,而无需分发样本,并为实验室识别原发性免疫缺陷症(PID)罕见的临床相关免疫表型提供了教育支持。该 EQAS 有助于提高 PID 诊断的质量,可作为未来罕见病流式细胞仪 EQAS 的范例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The EuroFlow PIDOT external quality assurance scheme: enhancing laboratory performance evaluation in immunophenotyping of rare lymphoid immunodeficiencies.

Objectives: The development of External Quality Assessment Schemes (EQAS) for clinical flow cytometry (FCM) is challenging in the context of rare (immunological) diseases. Here, we introduce a novel EQAS monitoring the primary immunodeficiency Orientation Tube (PIDOT), developed by EuroFlow, in both a 'wet' and 'dry' format. This EQAS provides feedback on the quality of individual laboratories (i.e., accuracy, reproducibility and result interpretation), while eliminating the need for sample distribution.

Methods: In the wet format, marker staining intensities (MedFIs) within landmark cell populations in PIDOT analysis performed on locally collected healthy control (HC) samples, were compared to EQAS targets. In the dry format, participants analyzed centrally distributed PIDOT flow cytometry data (n=10).

Results: We report the results of six EQAS rounds across 20 laboratories in 11 countries. The wet format (212 HC samples) demonstrated consistent technical performance among laboratories (median %rCV on MedFIs=34.5 %; average failure rate 17.3 %) and showed improvement upon repeated participation. The dry format demonstrated effective proficiency of participants in cell count enumeration (range %rCVs 3.1-7.1 % for the major lymphoid subsets), and in identifying lymphoid abnormalities (79.3 % alignment with reference).

Conclusions: The PIDOT-EQAS allows laboratories, adhering to the standardized EuroFlow approach, to monitor interlaboratory variations without the need for sample distribution, and provides them educational support to recognize rare clinically relevant immunophenotypic patterns of primary immunodeficiencies (PID). This EQAS contributes to quality improvement of PID diagnostics and can serve as an example for future flow cytometry EQAS in the context of rare diseases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
期刊最新文献
CD34+ progenitor cells meet metrology. Expanded carrier screening for 224 monogenic disease genes in 1,499 Chinese couples: a single-center study. Allowable total error in CD34 cell analysis by flow cytometry based on state of the art using Spanish EQAS data. Comparison of capillary finger stick and venous blood sampling for 34 routine chemistry analytes: potential for in the hospital and remote blood sampling. Diagnostic performances and cut-off verification of blood pTau 217 on the Lumipulse platform for amyloid deposition in Alzheimer's disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1