Benedetto Mangiavillano, Daryl Ramai, Michel Kahaleh, Amy Tyberg, Haroon Shahid, Avik Sarkar, Jayanta Samanta, Jahnvi Dhar, Michiel Bronswijk, Schalk Van der Merwe, Abdul Kouanda, Hyun Ji, Sun-Chuan Dai, Pierre Deprez, Jorge Vargas-Madrigal, Giuseppe Vanella, Leone Roberto, Paolo Giorgio Arcidiacono, Carlos Robles-Medranda, Juan Alcivar Vasquez, Martha Arevalo-Mora, Alessandro Fugazza, Christopher Ko, John Morris, Andrea Lisotti, Pietro Fusaroli, Amaninder Dhaliwal, Massimiliano Mutignani, Edoardo Forti, Irene Cottone, Alberto Larghi, Gianenrico Rizzatti, Domenico Galasso, Carmelo Barbera, Francesco Maria Di Matteo, Serena Stigliano, Cecilia Binda, Carlo Fabbri, Khanh Do-Cong Pham, Roberto Di Mitri, Michele Amata, Stefano Francesco Crinó, Andrew Ofosu, Luca De Luca, Abed Al-Lehibi, Francesco Auriemma, Danilo Paduano, Federica Calabrese, Carmine Gentile, Cesare Hassan, Alessandro Repici, Antonio Facciorusso
{"title":"在解剖结构发生手术改变的患者中放置腔隙贴壁金属支架的效果:多中心国际经验。","authors":"Benedetto Mangiavillano, Daryl Ramai, Michel Kahaleh, Amy Tyberg, Haroon Shahid, Avik Sarkar, Jayanta Samanta, Jahnvi Dhar, Michiel Bronswijk, Schalk Van der Merwe, Abdul Kouanda, Hyun Ji, Sun-Chuan Dai, Pierre Deprez, Jorge Vargas-Madrigal, Giuseppe Vanella, Leone Roberto, Paolo Giorgio Arcidiacono, Carlos Robles-Medranda, Juan Alcivar Vasquez, Martha Arevalo-Mora, Alessandro Fugazza, Christopher Ko, John Morris, Andrea Lisotti, Pietro Fusaroli, Amaninder Dhaliwal, Massimiliano Mutignani, Edoardo Forti, Irene Cottone, Alberto Larghi, Gianenrico Rizzatti, Domenico Galasso, Carmelo Barbera, Francesco Maria Di Matteo, Serena Stigliano, Cecilia Binda, Carlo Fabbri, Khanh Do-Cong Pham, Roberto Di Mitri, Michele Amata, Stefano Francesco Crinó, Andrew Ofosu, Luca De Luca, Abed Al-Lehibi, Francesco Auriemma, Danilo Paduano, Federica Calabrese, Carmine Gentile, Cesare Hassan, Alessandro Repici, Antonio Facciorusso","doi":"10.1055/a-2411-1814","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background and study aims</b> Although outcomes of lumen-apposing metal stents (LAMS) placement in native anatomy have been reported, data on LAMS placement in surgically altered anatomy (SAA) are sparse. We aimed to assess outcomes of LAMS placement in patients with SAA for different indications. <b>Patients and methods</b> This was an international, multicenter, retrospective, observational study at 25 tertiary care centers through November 2023. Consecutive patients with SAA who underwent LAMS placement were included. The primary outcome was technical success defined as correct placement of LAMS. Secondary outcomes were clinical success and safety. <b>Results</b> Two hundred and seventy patients (125 males; average age 61 ± 15 years) underwent LAMS placement with SAA. Procedures included EUS-directed transgastric ERCP (EDGE) and EUS-directed transenteric ERCP (EDEE) (n = 82), EUS-guided entero-enterostomy (n = 81), EUS-guided biliary drainage (n = 57), EUS-guided drainage of peri-pancreatic fluid collections (n = 48), and EUS-guided pancreaticogastrostomy (n = 2). Most cases utilized AXIOS stents (n = 255) compared with SPAXUS stents (n = 15). Overall, technical success was 98%, clinical success was 97%, and the adverse event (AE) rate was 12%. Using AGREE classification, five events were rated as Grade II, 21 events as Grade IIIa, and six events as IIIb. No difference in AEs were noted among stent types ( <i>P</i> = 0.52). <b>Conclusions</b> This study shows that placement of LAMS is associated with high technical and clinical success rates in patients with SAA. However, the rate of AEs is noteworthy, and thus, these procedures should be performed by expert endoscopists at tertiary centers.</p>","PeriodicalId":11671,"journal":{"name":"Endoscopy International Open","volume":"12 10","pages":"E1143-E1149"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11466529/pdf/","citationCount":"0","resultStr":"{\"title\":\"Outcomes of lumen apposing metal stent placement in patients with surgically altered anatomy: Multicenter international experience.\",\"authors\":\"Benedetto Mangiavillano, Daryl Ramai, Michel Kahaleh, Amy Tyberg, Haroon Shahid, Avik Sarkar, Jayanta Samanta, Jahnvi Dhar, Michiel Bronswijk, Schalk Van der Merwe, Abdul Kouanda, Hyun Ji, Sun-Chuan Dai, Pierre Deprez, Jorge Vargas-Madrigal, Giuseppe Vanella, Leone Roberto, Paolo Giorgio Arcidiacono, Carlos Robles-Medranda, Juan Alcivar Vasquez, Martha Arevalo-Mora, Alessandro Fugazza, Christopher Ko, John Morris, Andrea Lisotti, Pietro Fusaroli, Amaninder Dhaliwal, Massimiliano Mutignani, Edoardo Forti, Irene Cottone, Alberto Larghi, Gianenrico Rizzatti, Domenico Galasso, Carmelo Barbera, Francesco Maria Di Matteo, Serena Stigliano, Cecilia Binda, Carlo Fabbri, Khanh Do-Cong Pham, Roberto Di Mitri, Michele Amata, Stefano Francesco Crinó, Andrew Ofosu, Luca De Luca, Abed Al-Lehibi, Francesco Auriemma, Danilo Paduano, Federica Calabrese, Carmine Gentile, Cesare Hassan, Alessandro Repici, Antonio Facciorusso\",\"doi\":\"10.1055/a-2411-1814\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background and study aims</b> Although outcomes of lumen-apposing metal stents (LAMS) placement in native anatomy have been reported, data on LAMS placement in surgically altered anatomy (SAA) are sparse. We aimed to assess outcomes of LAMS placement in patients with SAA for different indications. <b>Patients and methods</b> This was an international, multicenter, retrospective, observational study at 25 tertiary care centers through November 2023. Consecutive patients with SAA who underwent LAMS placement were included. The primary outcome was technical success defined as correct placement of LAMS. Secondary outcomes were clinical success and safety. <b>Results</b> Two hundred and seventy patients (125 males; average age 61 ± 15 years) underwent LAMS placement with SAA. Procedures included EUS-directed transgastric ERCP (EDGE) and EUS-directed transenteric ERCP (EDEE) (n = 82), EUS-guided entero-enterostomy (n = 81), EUS-guided biliary drainage (n = 57), EUS-guided drainage of peri-pancreatic fluid collections (n = 48), and EUS-guided pancreaticogastrostomy (n = 2). Most cases utilized AXIOS stents (n = 255) compared with SPAXUS stents (n = 15). Overall, technical success was 98%, clinical success was 97%, and the adverse event (AE) rate was 12%. Using AGREE classification, five events were rated as Grade II, 21 events as Grade IIIa, and six events as IIIb. No difference in AEs were noted among stent types ( <i>P</i> = 0.52). <b>Conclusions</b> This study shows that placement of LAMS is associated with high technical and clinical success rates in patients with SAA. However, the rate of AEs is noteworthy, and thus, these procedures should be performed by expert endoscopists at tertiary centers.</p>\",\"PeriodicalId\":11671,\"journal\":{\"name\":\"Endoscopy International Open\",\"volume\":\"12 10\",\"pages\":\"E1143-E1149\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11466529/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endoscopy International Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2411-1814\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopy International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2411-1814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Outcomes of lumen apposing metal stent placement in patients with surgically altered anatomy: Multicenter international experience.
Background and study aims Although outcomes of lumen-apposing metal stents (LAMS) placement in native anatomy have been reported, data on LAMS placement in surgically altered anatomy (SAA) are sparse. We aimed to assess outcomes of LAMS placement in patients with SAA for different indications. Patients and methods This was an international, multicenter, retrospective, observational study at 25 tertiary care centers through November 2023. Consecutive patients with SAA who underwent LAMS placement were included. The primary outcome was technical success defined as correct placement of LAMS. Secondary outcomes were clinical success and safety. Results Two hundred and seventy patients (125 males; average age 61 ± 15 years) underwent LAMS placement with SAA. Procedures included EUS-directed transgastric ERCP (EDGE) and EUS-directed transenteric ERCP (EDEE) (n = 82), EUS-guided entero-enterostomy (n = 81), EUS-guided biliary drainage (n = 57), EUS-guided drainage of peri-pancreatic fluid collections (n = 48), and EUS-guided pancreaticogastrostomy (n = 2). Most cases utilized AXIOS stents (n = 255) compared with SPAXUS stents (n = 15). Overall, technical success was 98%, clinical success was 97%, and the adverse event (AE) rate was 12%. Using AGREE classification, five events were rated as Grade II, 21 events as Grade IIIa, and six events as IIIb. No difference in AEs were noted among stent types ( P = 0.52). Conclusions This study shows that placement of LAMS is associated with high technical and clinical success rates in patients with SAA. However, the rate of AEs is noteworthy, and thus, these procedures should be performed by expert endoscopists at tertiary centers.