Z CALC2 计算器与巴雷特散光计算器在散光人工晶体计算中的准确性比较。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2024-10-01 DOI:10.3928/1081597X-20240731-01
Lan Wang, Jiaqi Meng, Yanwen Fang, Wenwen He, Chen Zhao, Yi Lu, Xiangjia Zhu
{"title":"Z CALC2 计算器与巴雷特散光计算器在散光人工晶体计算中的准确性比较。","authors":"Lan Wang, Jiaqi Meng, Yanwen Fang, Wenwen He, Chen Zhao, Yi Lu, Xiangjia Zhu","doi":"10.3928/1081597X-20240731-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the accuracy of the Z CALC2 calculator and Barrett toric calculator in toric intraocular lens (IOL) calculation.</p><p><strong>Methods: </strong>Eighty-five eyes of 85 patients who underwent uneventful cataract surgery with toric IOL implantation were included. The accuracy was compared between the Z CALC2 calculator and Barrett toric calculator under two calculation modes: using simulated keratometry (SimK) from the IOLMaster 700 (Carl Zeiss Meditec AG) for posterior corneal astigmatism (PCA) prediction and employing total corneal astigmatism (total corneal refractive power [TCRP] or measured PCA) obtained from the Pentacam (Oculus Optikgeräte GmbH). The centroid of prediction errors, percentage of eyes with prediction errors within ±0.50 diopter (D), mean prediction error, and mean absolute prediction error were calculated. Subgroup analysis was conducted based on the orientation and magnitude of anterior corneal astigmatism and axial length.</p><p><strong>Results: </strong>When using SimK, the two calculators with predicted PCA showed comparable accuracy. When employing total corneal astigmatism, the Barrett toric calculator with measured PCA showed a lower centroid error (0.15 vs 0.38 D), a higher percentage of eyes with prediction errors within ±0.50 D (47.1% vs 32.9%, <i>P</i> = .018), and a lower mean prediction error (0.57 vs 0.71 D, <i>P</i> = .033) compared to the Z CALC2 calculator with TCRP in the 4-mm zone. In subgroup analysis, when employing total corneal astigmatism, the Barrett toric calculator with measured PCA exhibited superior accuracy, especially in the with-the-rule and anterior corneal astigmatism of 2.00 D or less subgroups.</p><p><strong>Conclusions: </strong>When using SimK, the Z CALC2 calculator and Barrett toric calculator yield comparable accuracy. The Barrett toric calculator with measured PCA may be more recommended when employing total corneal astigmatism. <b>[<i>J Refract Surg</i>. 2024;40(10):e681-e691.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the Accuracy Between the Z CALC2 Calculator and Barrett Toric Calculator in Toric IOL Calculation.\",\"authors\":\"Lan Wang, Jiaqi Meng, Yanwen Fang, Wenwen He, Chen Zhao, Yi Lu, Xiangjia Zhu\",\"doi\":\"10.3928/1081597X-20240731-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the accuracy of the Z CALC2 calculator and Barrett toric calculator in toric intraocular lens (IOL) calculation.</p><p><strong>Methods: </strong>Eighty-five eyes of 85 patients who underwent uneventful cataract surgery with toric IOL implantation were included. The accuracy was compared between the Z CALC2 calculator and Barrett toric calculator under two calculation modes: using simulated keratometry (SimK) from the IOLMaster 700 (Carl Zeiss Meditec AG) for posterior corneal astigmatism (PCA) prediction and employing total corneal astigmatism (total corneal refractive power [TCRP] or measured PCA) obtained from the Pentacam (Oculus Optikgeräte GmbH). The centroid of prediction errors, percentage of eyes with prediction errors within ±0.50 diopter (D), mean prediction error, and mean absolute prediction error were calculated. Subgroup analysis was conducted based on the orientation and magnitude of anterior corneal astigmatism and axial length.</p><p><strong>Results: </strong>When using SimK, the two calculators with predicted PCA showed comparable accuracy. When employing total corneal astigmatism, the Barrett toric calculator with measured PCA showed a lower centroid error (0.15 vs 0.38 D), a higher percentage of eyes with prediction errors within ±0.50 D (47.1% vs 32.9%, <i>P</i> = .018), and a lower mean prediction error (0.57 vs 0.71 D, <i>P</i> = .033) compared to the Z CALC2 calculator with TCRP in the 4-mm zone. In subgroup analysis, when employing total corneal astigmatism, the Barrett toric calculator with measured PCA exhibited superior accuracy, especially in the with-the-rule and anterior corneal astigmatism of 2.00 D or less subgroups.</p><p><strong>Conclusions: </strong>When using SimK, the Z CALC2 calculator and Barrett toric calculator yield comparable accuracy. The Barrett toric calculator with measured PCA may be more recommended when employing total corneal astigmatism. <b>[<i>J Refract Surg</i>. 2024;40(10):e681-e691.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20240731-01\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240731-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较 Z CALC2 计算器和 Barrett 散光计算器在散光人工晶体(IOL)计算中的准确性:方法:研究对象包括 85 名顺利进行白内障手术并植入散光人工晶体的患者的 85 只眼睛。比较了Z CALC2计算器和Barrett散光计算器在两种计算模式下的准确性:使用IOLMaster 700(卡尔蔡司医疗有限公司)的模拟角膜测量(SimK)预测角膜后散光(PCA),以及使用Pentacam(Oculus Optikgeräte GmbH)获得的总角膜散光(总角膜屈光力[TCRP]或测量的PCA)。计算了预测误差的中心点、预测误差在±0.50屈光度(D)以内的眼睛百分比、平均预测误差和平均绝对预测误差。根据前角膜散光的方向和大小以及轴长进行了分组分析:结果:使用 SimK 时,两种预测 PCA 的计算器显示出相当的准确性。与使用 4 毫米区 TCRP 的 Z CALC2 计算器相比,在使用总角膜散光时,使用测量 PCA 的 Barrett 散光计算器显示出更低的中心误差(0.15 vs 0.38 D),预测误差在 ±0.50 D 以内的眼睛比例更高(47.1% vs 32.9%,P = .018),平均预测误差更低(0.57 vs 0.71 D,P = .033)。在分组分析中,当采用角膜总散光度数时,带有测量 PCA 的 Barrett 散光计算器显示出更高的准确性,尤其是在带规则和前角膜散光度数为 2.00 D 或更小的分组中:结论:使用 SimK 时,Z CALC2 计算器和巴雷特散光计算器的准确度相当。在使用全角膜散光时,更推荐使用带有测量PCA的Barrett散光计算器。[J Refract Surg. 2024;40(10):e681-e691]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the Accuracy Between the Z CALC2 Calculator and Barrett Toric Calculator in Toric IOL Calculation.

Purpose: To compare the accuracy of the Z CALC2 calculator and Barrett toric calculator in toric intraocular lens (IOL) calculation.

Methods: Eighty-five eyes of 85 patients who underwent uneventful cataract surgery with toric IOL implantation were included. The accuracy was compared between the Z CALC2 calculator and Barrett toric calculator under two calculation modes: using simulated keratometry (SimK) from the IOLMaster 700 (Carl Zeiss Meditec AG) for posterior corneal astigmatism (PCA) prediction and employing total corneal astigmatism (total corneal refractive power [TCRP] or measured PCA) obtained from the Pentacam (Oculus Optikgeräte GmbH). The centroid of prediction errors, percentage of eyes with prediction errors within ±0.50 diopter (D), mean prediction error, and mean absolute prediction error were calculated. Subgroup analysis was conducted based on the orientation and magnitude of anterior corneal astigmatism and axial length.

Results: When using SimK, the two calculators with predicted PCA showed comparable accuracy. When employing total corneal astigmatism, the Barrett toric calculator with measured PCA showed a lower centroid error (0.15 vs 0.38 D), a higher percentage of eyes with prediction errors within ±0.50 D (47.1% vs 32.9%, P = .018), and a lower mean prediction error (0.57 vs 0.71 D, P = .033) compared to the Z CALC2 calculator with TCRP in the 4-mm zone. In subgroup analysis, when employing total corneal astigmatism, the Barrett toric calculator with measured PCA exhibited superior accuracy, especially in the with-the-rule and anterior corneal astigmatism of 2.00 D or less subgroups.

Conclusions: When using SimK, the Z CALC2 calculator and Barrett toric calculator yield comparable accuracy. The Barrett toric calculator with measured PCA may be more recommended when employing total corneal astigmatism. [J Refract Surg. 2024;40(10):e681-e691.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
AI Will Never Reach Human Beauty. Clinical Performance of an Extended Range of Vision Intraocular Lens After LASIK. Comparison Between Monofocal and Aspheric Monofocal Intraocular Lens With Higher Order Aspheric Optic in Pediatric Patients: Early Outcomes. Comparison of the Accuracy Between the Z CALC2 Calculator and Barrett Toric Calculator in Toric IOL Calculation. Corneal Epithelial Remodeling Following Cylinder Correction With SMILE or FS-LASIK: A Contralateral Comparative Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1