利用临床样本体外筛选人脑脊液特异性适配体。

IF 4.8 2区 医学 Q1 OTORHINOLARYNGOLOGY Rhinology Pub Date : 2025-02-01 DOI:10.4193/Rhin24.341
A Abiri, X Chen, B Latifi, F P K Hsu, A Luptak, M Khine, E C Kuan
{"title":"利用临床样本体外筛选人脑脊液特异性适配体。","authors":"A Abiri, X Chen, B Latifi, F P K Hsu, A Luptak, M Khine, E C Kuan","doi":"10.4193/Rhin24.341","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cerebrospinal fluid (CSF) leaks may occur due to numerous etiologies and are associated with severe morbidity. Currently in the U.S., confirming the presence of a CSF leak requires protein electrophoresis testing, oftentimes involving specialized processing, and there exists no point-of-care (POC) device for CSF detection. We aimed to discover a single-stranded deoxyribonucleic acid (ssDNA) aptamer capable of selectively binding to CSF-specific biomarkers, with the future goal of developing an aptamer-based POC CSF detection device.</p><p><strong>Methods: </strong>To identify a candidate aptamer, we performed Systematic Evolution of Ligands by EXponential enrichment (SELEX) using a DNA library containing a randomized 63-nucleotide (nt) stretch flanked by 2 primer-binding sites. Quantitative polymerase chain reaction (qPCR) and fluorescence anisotropy (FA) assessed aptamer binding affinity and kinetics.</p><p><strong>Results: </strong>Following 14 SELEX cycles, 2 dominant and functionally viable 98-nt ssDNA sequences (C2 and C3) were found. C2 and C3 demonstrated ~586x and ~82x higher affinity for CSF compared to serum, respectively. Increases in FA upon aptamer exposure to higher CSF concentrations demonstrated a K1/2 of 5.0% and 14.1% for C2 and C3, respectively.</p><p><strong>Conclusions: </strong>In vitro selection of a diverse pool of ssDNA sequences yielded 2 aptamers with high selectivity for CSF-specific biomarkers, with potential for integration into a rapid POC electrochemical diagnostic system.</p>","PeriodicalId":21361,"journal":{"name":"Rhinology","volume":" ","pages":"103-112"},"PeriodicalIF":4.8000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro selection of human cerebrospinal fluid-specific aptamers using clinical samples.\",\"authors\":\"A Abiri, X Chen, B Latifi, F P K Hsu, A Luptak, M Khine, E C Kuan\",\"doi\":\"10.4193/Rhin24.341\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cerebrospinal fluid (CSF) leaks may occur due to numerous etiologies and are associated with severe morbidity. Currently in the U.S., confirming the presence of a CSF leak requires protein electrophoresis testing, oftentimes involving specialized processing, and there exists no point-of-care (POC) device for CSF detection. We aimed to discover a single-stranded deoxyribonucleic acid (ssDNA) aptamer capable of selectively binding to CSF-specific biomarkers, with the future goal of developing an aptamer-based POC CSF detection device.</p><p><strong>Methods: </strong>To identify a candidate aptamer, we performed Systematic Evolution of Ligands by EXponential enrichment (SELEX) using a DNA library containing a randomized 63-nucleotide (nt) stretch flanked by 2 primer-binding sites. Quantitative polymerase chain reaction (qPCR) and fluorescence anisotropy (FA) assessed aptamer binding affinity and kinetics.</p><p><strong>Results: </strong>Following 14 SELEX cycles, 2 dominant and functionally viable 98-nt ssDNA sequences (C2 and C3) were found. C2 and C3 demonstrated ~586x and ~82x higher affinity for CSF compared to serum, respectively. Increases in FA upon aptamer exposure to higher CSF concentrations demonstrated a K1/2 of 5.0% and 14.1% for C2 and C3, respectively.</p><p><strong>Conclusions: </strong>In vitro selection of a diverse pool of ssDNA sequences yielded 2 aptamers with high selectivity for CSF-specific biomarkers, with potential for integration into a rapid POC electrochemical diagnostic system.</p>\",\"PeriodicalId\":21361,\"journal\":{\"name\":\"Rhinology\",\"volume\":\" \",\"pages\":\"103-112\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rhinology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4193/Rhin24.341\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rhinology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4193/Rhin24.341","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:脑脊液(CSF)漏可能由多种病因引起,并与严重的发病率有关。目前在美国,确认是否存在脑脊液漏需要进行蛋白电泳检测,有时还需要进行专门的处理,而且还没有用于脑脊液检测的护理点(POC)设备。我们的目标是发现一种能与 CSF 特异性生物标记物选择性结合的单链脱氧核糖核酸(ssDNA)适配体,以便将来开发基于适配体的 POC CSF 检测设备:为了确定候选的适配体,我们利用DNA文库进行了EXponential富集配体的系统进化(SELEX),该文库包含一个随机的63个核苷酸(nt)的片段,两侧有2个引物结合位点。定量聚合酶链反应(qPCR)和荧光各向异性(FA)评估了适配体的结合亲和力和动力学:结果:经过 14 个 SELEX 循环,发现了 2 个优势且功能可行的 98-nt ssDNA 序列(C2 和 C3)。与血清相比,C2 和 C3 对 CSF 的亲和力分别高出 ~586 倍和 ~82 倍。C2和C3的K1⁄2分别为5.0%和14.1%:结论:体外选择不同的 ssDNA 序列库产生了 2 种对 CSF 特异性生物标记物具有高选择性的适配体,有望整合到快速 POC 电化学诊断系统中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro selection of human cerebrospinal fluid-specific aptamers using clinical samples.

Background: Cerebrospinal fluid (CSF) leaks may occur due to numerous etiologies and are associated with severe morbidity. Currently in the U.S., confirming the presence of a CSF leak requires protein electrophoresis testing, oftentimes involving specialized processing, and there exists no point-of-care (POC) device for CSF detection. We aimed to discover a single-stranded deoxyribonucleic acid (ssDNA) aptamer capable of selectively binding to CSF-specific biomarkers, with the future goal of developing an aptamer-based POC CSF detection device.

Methods: To identify a candidate aptamer, we performed Systematic Evolution of Ligands by EXponential enrichment (SELEX) using a DNA library containing a randomized 63-nucleotide (nt) stretch flanked by 2 primer-binding sites. Quantitative polymerase chain reaction (qPCR) and fluorescence anisotropy (FA) assessed aptamer binding affinity and kinetics.

Results: Following 14 SELEX cycles, 2 dominant and functionally viable 98-nt ssDNA sequences (C2 and C3) were found. C2 and C3 demonstrated ~586x and ~82x higher affinity for CSF compared to serum, respectively. Increases in FA upon aptamer exposure to higher CSF concentrations demonstrated a K1/2 of 5.0% and 14.1% for C2 and C3, respectively.

Conclusions: In vitro selection of a diverse pool of ssDNA sequences yielded 2 aptamers with high selectivity for CSF-specific biomarkers, with potential for integration into a rapid POC electrochemical diagnostic system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Rhinology
Rhinology 医学-耳鼻喉科学
CiteScore
15.80
自引率
9.70%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Rhinology serves as the official Journal of the International Rhinologic Society and is recognized as one of the journals of the European Rhinologic Society. It offers a prominent platform for disseminating rhinologic research, reviews, position papers, task force reports, and guidelines to an international scientific audience. The journal also boasts the prestigious European Position Paper in Rhinosinusitis (EPOS), a highly influential publication first released in 2005 and subsequently updated in 2007, 2012, and most recently in 2020. Employing a double-blind peer review system, Rhinology welcomes original articles, review articles, and letters to the editor.
期刊最新文献
Is nasal closure an effective treatment for severe refractory epistaxis in HHT? A scoping review and narrative synthesis. Analysis of nasal fracture management and subsequent surgical outcomes across demographics. Omalizumab reduces allergic rhinitis symptoms due to Japanese cedar pollen by improving eosinophilic inflammation. Normative data for the lateralization task in the assessment of intranasal trigeminal function. Nasal endoscopy score thresholds to trigger consideration of chronic rhinosinusitis treatment escalation and implications for disease control.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1