Alina Chigri, Stephen Gerfer, Coman Horatiu, Ihor Krasivskyi, Maximilian Luehr, Ilija Djordjevic, Thorsten Wahlers, Justus Strauch, Peter Haldenwang
{"title":"升主动脉置换术中血管移植类型对术后早期疗效的影响。","authors":"Alina Chigri, Stephen Gerfer, Coman Horatiu, Ihor Krasivskyi, Maximilian Luehr, Ilija Djordjevic, Thorsten Wahlers, Justus Strauch, Peter Haldenwang","doi":"10.1177/02676591241291346","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Aim of this study was to find out if the type of vascular prosthesis used, especially collagen impregnated polyester versus gelatin impregnated woven fabric graft, has any impact on the early postoperative bleeding rate, blood product consumption and re-thoracotomy rate in isolated ascending aortic surgery.</p><p><strong>Methods: </strong><i>n</i> = 46 consecutive patients who received a supra-commissural replacement of the ascending aorta between 01/2016 - 01/ 2021 were included in this retrospective single-center study. The underlying pathology was an aortic aneurysm in 36 (81 %) and/or an acute type A aortic dissection (ATAAD) limited to the ascending aorta in 7 (15 %) and/or a penetrating aortic ulcer (PAU) with intramural hematoma in 6 (13 %) patients. According to the type of vascular graft used, the cohort was divided as follows: 25 patients (54%) received a double velour woven, collagen impregnated polyester graft (Hemashield, Getinge; CI-Group) whereas in 21 patients (46 %) a gelatin impregnated woven fabric graft was used (Gelweave, Vascutek / Terumo; GI-group). As primary endpoints class 3 bleeding according to the Valve Academic Research Consortium (VARC3) criteria and freedom from re-intervention were assessed. As secondary endpoints, 30-day mortality and stroke were defined.</p><p><strong>Results: </strong>Preoperative risk assessment (EuroSCORE II), gender-, BMI-stratification and NYHA-classification as well as mean CPB-times (114 ± 44 min vs 110 ± 48 min) and aortic cross-clamp times (71 ± 28 min vs 66 ± 30 min) were similar in both groups. Bleeding, measured by drainage volume output within the first postoperative 24 h (480 ± 426 mL vs 389 ± 169 mL), erythrocytes concentrate consumption (2,4 vs 2,3) and similar re-thoracotomy rates (4 vs 4.7 %) showed no difference between groups. 30- day mortality (12 vs 5 %; <i>p</i> = 0.614) and stroke rates (4 vs 9.5; <i>p</i> = 0,4) showed no differences between groups.</p><p><strong>Conclusions: </strong>Regarding postoperative bleeding no difference were seen between the two graft types. Long-term follow-up and larger prospective randomized studies are requested to prove these findings.</p>","PeriodicalId":49707,"journal":{"name":"Perfusion-Uk","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of vascular graft type for ascending aorta replacement on the early postoperative outcome.\",\"authors\":\"Alina Chigri, Stephen Gerfer, Coman Horatiu, Ihor Krasivskyi, Maximilian Luehr, Ilija Djordjevic, Thorsten Wahlers, Justus Strauch, Peter Haldenwang\",\"doi\":\"10.1177/02676591241291346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Aim of this study was to find out if the type of vascular prosthesis used, especially collagen impregnated polyester versus gelatin impregnated woven fabric graft, has any impact on the early postoperative bleeding rate, blood product consumption and re-thoracotomy rate in isolated ascending aortic surgery.</p><p><strong>Methods: </strong><i>n</i> = 46 consecutive patients who received a supra-commissural replacement of the ascending aorta between 01/2016 - 01/ 2021 were included in this retrospective single-center study. The underlying pathology was an aortic aneurysm in 36 (81 %) and/or an acute type A aortic dissection (ATAAD) limited to the ascending aorta in 7 (15 %) and/or a penetrating aortic ulcer (PAU) with intramural hematoma in 6 (13 %) patients. According to the type of vascular graft used, the cohort was divided as follows: 25 patients (54%) received a double velour woven, collagen impregnated polyester graft (Hemashield, Getinge; CI-Group) whereas in 21 patients (46 %) a gelatin impregnated woven fabric graft was used (Gelweave, Vascutek / Terumo; GI-group). As primary endpoints class 3 bleeding according to the Valve Academic Research Consortium (VARC3) criteria and freedom from re-intervention were assessed. As secondary endpoints, 30-day mortality and stroke were defined.</p><p><strong>Results: </strong>Preoperative risk assessment (EuroSCORE II), gender-, BMI-stratification and NYHA-classification as well as mean CPB-times (114 ± 44 min vs 110 ± 48 min) and aortic cross-clamp times (71 ± 28 min vs 66 ± 30 min) were similar in both groups. Bleeding, measured by drainage volume output within the first postoperative 24 h (480 ± 426 mL vs 389 ± 169 mL), erythrocytes concentrate consumption (2,4 vs 2,3) and similar re-thoracotomy rates (4 vs 4.7 %) showed no difference between groups. 30- day mortality (12 vs 5 %; <i>p</i> = 0.614) and stroke rates (4 vs 9.5; <i>p</i> = 0,4) showed no differences between groups.</p><p><strong>Conclusions: </strong>Regarding postoperative bleeding no difference were seen between the two graft types. Long-term follow-up and larger prospective randomized studies are requested to prove these findings.</p>\",\"PeriodicalId\":49707,\"journal\":{\"name\":\"Perfusion-Uk\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Perfusion-Uk\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02676591241291346\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perfusion-Uk","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02676591241291346","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
研究背景本研究旨在了解所使用的血管假体类型(尤其是胶原浸渍聚酯与明胶浸渍编织物移植物)是否会对孤立升主动脉手术的术后早期出血率、血液制品消耗量和再次开胸率产生影响。36例(81%)患者的病理基础是主动脉瘤,7例(15%)患者的病理基础是局限于升主动脉的急性A型主动脉夹层(ATAAD),6例(13%)患者的病理基础是伴有壁内血肿的穿透性主动脉溃疡(PAU)。根据使用的血管移植类型,组群划分如下:25名患者(54%)使用了双层丝绒编织胶原浸渍聚酯移植物(Hemashield,Getinge;CI组),21名患者(46%)使用了明胶浸渍编织物移植物(Gelweave,Vascutek/Terumo;GI组)。根据瓣膜学术研究联盟(VARC3)的标准,评估的主要终点是3级出血和无再介入。次要终点是30天死亡率和中风:结果:两组患者的术前风险评估(EuroSCORE II)、性别、BMI分级、NYHA分级以及平均CPB时间(114±44分钟 vs 110±48分钟)和主动脉交叉钳夹时间(71±28分钟 vs 66±30分钟)相似。根据术后 24 小时内的引流量(480 ± 426 mL vs 389 ± 169 mL)、红细胞浓缩物消耗量(2.4 vs 2.3)和相似的再次开胸率(4 vs 4.7%)测量的出血量在两组之间没有差异。30天死亡率(12% 对 5%;P = 0.614)和中风率(4% 对 9.5%;P = 0.4)在各组之间没有差异:结论:在术后出血方面,两种移植物之间没有差异。需要进行长期随访和更大规模的前瞻性随机研究来证明这些结果。
Influence of vascular graft type for ascending aorta replacement on the early postoperative outcome.
Background: Aim of this study was to find out if the type of vascular prosthesis used, especially collagen impregnated polyester versus gelatin impregnated woven fabric graft, has any impact on the early postoperative bleeding rate, blood product consumption and re-thoracotomy rate in isolated ascending aortic surgery.
Methods: n = 46 consecutive patients who received a supra-commissural replacement of the ascending aorta between 01/2016 - 01/ 2021 were included in this retrospective single-center study. The underlying pathology was an aortic aneurysm in 36 (81 %) and/or an acute type A aortic dissection (ATAAD) limited to the ascending aorta in 7 (15 %) and/or a penetrating aortic ulcer (PAU) with intramural hematoma in 6 (13 %) patients. According to the type of vascular graft used, the cohort was divided as follows: 25 patients (54%) received a double velour woven, collagen impregnated polyester graft (Hemashield, Getinge; CI-Group) whereas in 21 patients (46 %) a gelatin impregnated woven fabric graft was used (Gelweave, Vascutek / Terumo; GI-group). As primary endpoints class 3 bleeding according to the Valve Academic Research Consortium (VARC3) criteria and freedom from re-intervention were assessed. As secondary endpoints, 30-day mortality and stroke were defined.
Results: Preoperative risk assessment (EuroSCORE II), gender-, BMI-stratification and NYHA-classification as well as mean CPB-times (114 ± 44 min vs 110 ± 48 min) and aortic cross-clamp times (71 ± 28 min vs 66 ± 30 min) were similar in both groups. Bleeding, measured by drainage volume output within the first postoperative 24 h (480 ± 426 mL vs 389 ± 169 mL), erythrocytes concentrate consumption (2,4 vs 2,3) and similar re-thoracotomy rates (4 vs 4.7 %) showed no difference between groups. 30- day mortality (12 vs 5 %; p = 0.614) and stroke rates (4 vs 9.5; p = 0,4) showed no differences between groups.
Conclusions: Regarding postoperative bleeding no difference were seen between the two graft types. Long-term follow-up and larger prospective randomized studies are requested to prove these findings.
期刊介绍:
Perfusion is an ISI-ranked, peer-reviewed scholarly journal, which provides current information on all aspects of perfusion, oxygenation and biocompatibility and their use in modern cardiac surgery. The journal is at the forefront of international research and development and presents an appropriately multidisciplinary approach to perfusion science.