β-2转铁蛋白凝胶电泳检测脑脊液鼻出血的诊断准确性。

IF 2.2 3区 医学 Q3 MEDICINE, RESEARCH & EXPERIMENTAL Laryngoscope Pub Date : 2024-10-14 DOI:10.1002/lary.31845
Jacob G Eide, William Mason, Hussein Mackie, Bernard Cook, Amrita Ray, Karam Asmaro, Adam Robin, Jack Rock, John R Craig
{"title":"β-2转铁蛋白凝胶电泳检测脑脊液鼻出血的诊断准确性。","authors":"Jacob G Eide, William Mason, Hussein Mackie, Bernard Cook, Amrita Ray, Karam Asmaro, Adam Robin, Jack Rock, John R Craig","doi":"10.1002/lary.31845","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta-2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%-100%) and specificity (71%-100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single-institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.</p><p><strong>Methods: </strong>A single-center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.</p><p><strong>Results: </strong>A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2-Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis (n = 6, 23.1%), possible mucous contamination from nose-blowing during collection (n = 3, 11.5%), patient collection error (n = 3, 11.5%), and blood contamination (n = 1, 3.8%).</p><p><strong>Conclusion: </strong>Although these single-institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision-making.</p><p><strong>Level of evidence: </strong>IV Laryngoscope, 2024.</p>","PeriodicalId":49921,"journal":{"name":"Laryngoscope","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic Accuracy of Beta-2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea.\",\"authors\":\"Jacob G Eide, William Mason, Hussein Mackie, Bernard Cook, Amrita Ray, Karam Asmaro, Adam Robin, Jack Rock, John R Craig\",\"doi\":\"10.1002/lary.31845\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta-2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%-100%) and specificity (71%-100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single-institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.</p><p><strong>Methods: </strong>A single-center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.</p><p><strong>Results: </strong>A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2-Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis (n = 6, 23.1%), possible mucous contamination from nose-blowing during collection (n = 3, 11.5%), patient collection error (n = 3, 11.5%), and blood contamination (n = 1, 3.8%).</p><p><strong>Conclusion: </strong>Although these single-institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision-making.</p><p><strong>Level of evidence: </strong>IV Laryngoscope, 2024.</p>\",\"PeriodicalId\":49921,\"journal\":{\"name\":\"Laryngoscope\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laryngoscope\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/lary.31845\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laryngoscope","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/lary.31845","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:单侧稀薄透明鼻涕(UTCR)可能代表多种病症,包括脑脊液(CSF)鼻出血。据报道,β-2 转铁蛋白(B2Tf)凝胶电泳(GE)具有较高的灵敏度(87%-100%)和特异性(71%-100%),已成为首选的检测方式。然而,评估其诊断准确性的研究相对较少。本研究旨在确定 B2Tf GE 检测 CSF 鼻出血的准确性:方法:从 2016 年到 2024 年,对所有出现 UTCR 并接受 B2Tf GE 的患者进行了单中心回顾性研究。该研究获得了机构审查委员会的批准。诊断确认真阳性、假阳性(TP、FP)和假阴性(FN)的金标准是内镜探查。真阴性(TN)的金标准是对药物治疗的反应:共有 105 名患者接受了 149 次 B2Tf GE 检测。40例(38.1%)患者被诊断为鼻脓肿。在 149 次 B2-Tf GE 检测中,有 51 个 TP、72 个 TN、20 个 FP 和 6 个 FN,灵敏度分别为 89.5%、78.3%、71.8% 的阳性预测值和 92.3% 的阴性预测值。在错误结果中,最常见的错误原因是化脓性鼻窦炎(6 例,23.1%)、采集过程中擤鼻涕可能造成的粘液污染(3 例,11.5%)、患者采集错误(3 例,11.5%)和血液污染(1 例,3.8%):结论:尽管这些单个机构的数据显示测试准确性在文献之前报道的范围内,但也显示了诊断的局限性。未来的研究应探讨 B2Tf GE 结果错误的原因,以及这些原因会如何改变临床决策:IV 《喉镜》,2024 年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Diagnostic Accuracy of Beta-2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea.

Objective: Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta-2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%-100%) and specificity (71%-100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single-institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.

Methods: A single-center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.

Results: A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2-Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis (n = 6, 23.1%), possible mucous contamination from nose-blowing during collection (n = 3, 11.5%), patient collection error (n = 3, 11.5%), and blood contamination (n = 1, 3.8%).

Conclusion: Although these single-institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision-making.

Level of evidence: IV Laryngoscope, 2024.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Laryngoscope
Laryngoscope 医学-耳鼻喉科学
CiteScore
6.50
自引率
7.70%
发文量
500
审稿时长
2-4 weeks
期刊介绍: The Laryngoscope has been the leading source of information on advances in the diagnosis and treatment of head and neck disorders since 1890. The Laryngoscope is the first choice among otolaryngologists for publication of their important findings and techniques. Each monthly issue of The Laryngoscope features peer-reviewed medical, clinical, and research contributions in general otolaryngology, allergy/rhinology, otology/neurotology, laryngology/bronchoesophagology, head and neck surgery, sleep medicine, pediatric otolaryngology, facial plastics and reconstructive surgery, oncology, and communicative disorders. Contributions include papers and posters presented at the Annual and Section Meetings of the Triological Society, as well as independent papers, "How I Do It", "Triological Best Practice" articles, and contemporary reviews. Theses authored by the Triological Society’s new Fellows as well as papers presented at meetings of the American Laryngological Association are published in The Laryngoscope. • Broncho-esophagology • Communicative disorders • Head and neck surgery • Plastic and reconstructive facial surgery • Oncology • Speech and hearing defects
期刊最新文献
Otolaryngologists Demonstrate Low Agreement on Pediatric Airway Inflammation Assessment. A Predictive Model for Oral Intake Independence in Dysphagia Treatment. Classifications of Postradiation Nasopharyngeal Necrosis for Guiding Transnasal Endoscopic Nasopharyngeal Skull Base Surgery. Clinical Phenotypic Characterization of the SLC26A4 Mutation in Pendred Syndrome/Nonsyndromic Enlarged Vestibular Aqueduct. Scala Tympani Volume Influences Initial 6-Month Hearing Preservation With Lateral Wall Electrode Arrays.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1