采用收缩末期冠状动脉 CTA 采集和自动剂量选择的机构流程变革对患者吞吐量和图像质量的影响。

Nisha Hosadurg, Kara Harrison, Joseph Dan Khoa Nguyen, Patricia Rodriguez Lozano, Christopher M Kramer, Patrick T Norton, Amit R Patel, Todd C Villines
{"title":"采用收缩末期冠状动脉 CTA 采集和自动剂量选择的机构流程变革对患者吞吐量和图像质量的影响。","authors":"Nisha Hosadurg, Kara Harrison, Joseph Dan Khoa Nguyen, Patricia Rodriguez Lozano, Christopher M Kramer, Patrick T Norton, Amit R Patel, Todd C Villines","doi":"10.1016/j.jcct.2024.10.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Guidelines recommend prospective ECG-triggered mid-diastolic coronary computed tomographic angiography (CCTA) acquisition after achieving optimal heart rate (HR) control in order to optimize scan image quality. With dual-source CCTA, prospective end-systolic acquisition has been shown to be less prone to motion artifacts at higher heart rates and may improve scan and CT laboratory efficiency by allowing CCTA without routine pre-scan beta-blocker (BB) administration.</p><p><strong>Methods: </strong>We implemented an institutional process change in CCTA performance effective January 2023, comprising a transition from prospective ECG-triggered mid-diastolic acquisitions individually supervised by a physician at the scanner to an algorithmic approach predominately utilizing prospective end-systolic acquisition (200-400 ​ms after R peak), employing an automated dose selection algorithm, without BB administration. All scans were performed on a third-generation 192-slice dual-source scanner. We reviewed 300 consecutive CCTAs done pre- and post-process change in Jan 2022 (phase 0), Jan 2023 (phase 1), and in May 2023 (phase 2) after implementation of a process improvement involving more selective utilization of automated tube potential/current algorithms (CARE kV) to optimize image quality. Coronary segmental image quality was assessed by two experienced CCTA readers by consensus using an 18-segment SCCT model on a 5-point Likert scale (1 ​= ​non-interpretable; 2 ​= ​poor; 3 ​= ​acceptable; 4 ​= ​good; 5 ​= ​excellent). Measures of radiation dose, medication administration, and time required for patient scanning were compared. Logistic regression was used to determine factors associated with patient-level reduction in image quality (IQ) and with repeat scans.</p><p><strong>Results: </strong>Post-process change, there was a significant reduction in the median overall patient appointment [phase 0: 95 (75-125) min vs. phase 1: 68 (52-88) min and phase 2: 72 (59-90) min; P ​< ​0.001] and scan times [phase 0: 13 (10-16) min vs. phase 1: 8 (6-13) min and phase 2: 9 (7-13) min; P ​< ​0.001]. Median IQ score in both post-process change phases was 4 (4-5) compared to a median score of 5 (4-5) pre-process change (P for comparison <0.001). The majority of segments post-process change had \"good\" IQ (Phase 1 segmental IQ scores: 5 ​= ​36.7 ​%, 4 ​= ​46.8 ​%, 3 ​= ​13 ​%, 2 ​= ​2.6 ​%, 1 ​= ​0.9 ​%; Phase 2 segmental IQ scores: 5 ​= ​26 ​%, 4 ​= ​49.7 ​%, 3 ​= ​16.3 ​%, 2 ​= ​6.1 ​%, 1 ​= ​1.9 ​%), whereas pre-process change, the majority of segments had \"excellent\" IQ (Phase 0 segmental IQ scores: 5 ​= ​56 ​%, 4 ​= ​34.3 ​%, 3 ​= ​7.5 ​%, 2 ​= ​1.8 ​%, 1 ​= ​0.4 ​%) There was no significant increase in non-interpretable scans at the patient level. The 22 ​% re-scan rate in phase 1 (vs. 6 ​% in phase 0, P ​= ​.002) improved to 15 ​% in phase 2. While patient related factors of body mass index [adjusted OR obese 2.64, 95 ​% CI 1.12-6.51, P ​= ​0.03; aOR morbidly obese 6.94, 95 ​% CI 2.21-23.52, P ​= ​0.001] and average HR [aOR (per 10 bpm increase) 1.51, 95 ​% CI 1.21-1.9, P ​< ​0.001] were associated with the scoring of any segment as ​≤ ​3 ​at the patient level in a fully adjusted model, the improved phase 2 of the process change was not [aOR 1.61, 95 ​% CI 0.78-3.32].</p><p><strong>Conclusion: </strong>Implementation of an institutional process change utilizing prospective ECG-triggered dual-source end-systolic acquisition avoided the use of beta-blockers, significantly reduced patient appointment and scan times with acceptable diagnostic performance.</p>","PeriodicalId":94071,"journal":{"name":"Journal of cardiovascular computed tomography","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of an institutional process change adopting end-systolic coronary CTA acquisition and automated dose selection on patient throughput and image quality.\",\"authors\":\"Nisha Hosadurg, Kara Harrison, Joseph Dan Khoa Nguyen, Patricia Rodriguez Lozano, Christopher M Kramer, Patrick T Norton, Amit R Patel, Todd C Villines\",\"doi\":\"10.1016/j.jcct.2024.10.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Guidelines recommend prospective ECG-triggered mid-diastolic coronary computed tomographic angiography (CCTA) acquisition after achieving optimal heart rate (HR) control in order to optimize scan image quality. With dual-source CCTA, prospective end-systolic acquisition has been shown to be less prone to motion artifacts at higher heart rates and may improve scan and CT laboratory efficiency by allowing CCTA without routine pre-scan beta-blocker (BB) administration.</p><p><strong>Methods: </strong>We implemented an institutional process change in CCTA performance effective January 2023, comprising a transition from prospective ECG-triggered mid-diastolic acquisitions individually supervised by a physician at the scanner to an algorithmic approach predominately utilizing prospective end-systolic acquisition (200-400 ​ms after R peak), employing an automated dose selection algorithm, without BB administration. All scans were performed on a third-generation 192-slice dual-source scanner. We reviewed 300 consecutive CCTAs done pre- and post-process change in Jan 2022 (phase 0), Jan 2023 (phase 1), and in May 2023 (phase 2) after implementation of a process improvement involving more selective utilization of automated tube potential/current algorithms (CARE kV) to optimize image quality. Coronary segmental image quality was assessed by two experienced CCTA readers by consensus using an 18-segment SCCT model on a 5-point Likert scale (1 ​= ​non-interpretable; 2 ​= ​poor; 3 ​= ​acceptable; 4 ​= ​good; 5 ​= ​excellent). Measures of radiation dose, medication administration, and time required for patient scanning were compared. Logistic regression was used to determine factors associated with patient-level reduction in image quality (IQ) and with repeat scans.</p><p><strong>Results: </strong>Post-process change, there was a significant reduction in the median overall patient appointment [phase 0: 95 (75-125) min vs. phase 1: 68 (52-88) min and phase 2: 72 (59-90) min; P ​< ​0.001] and scan times [phase 0: 13 (10-16) min vs. phase 1: 8 (6-13) min and phase 2: 9 (7-13) min; P ​< ​0.001]. Median IQ score in both post-process change phases was 4 (4-5) compared to a median score of 5 (4-5) pre-process change (P for comparison <0.001). The majority of segments post-process change had \\\"good\\\" IQ (Phase 1 segmental IQ scores: 5 ​= ​36.7 ​%, 4 ​= ​46.8 ​%, 3 ​= ​13 ​%, 2 ​= ​2.6 ​%, 1 ​= ​0.9 ​%; Phase 2 segmental IQ scores: 5 ​= ​26 ​%, 4 ​= ​49.7 ​%, 3 ​= ​16.3 ​%, 2 ​= ​6.1 ​%, 1 ​= ​1.9 ​%), whereas pre-process change, the majority of segments had \\\"excellent\\\" IQ (Phase 0 segmental IQ scores: 5 ​= ​56 ​%, 4 ​= ​34.3 ​%, 3 ​= ​7.5 ​%, 2 ​= ​1.8 ​%, 1 ​= ​0.4 ​%) There was no significant increase in non-interpretable scans at the patient level. The 22 ​% re-scan rate in phase 1 (vs. 6 ​% in phase 0, P ​= ​.002) improved to 15 ​% in phase 2. While patient related factors of body mass index [adjusted OR obese 2.64, 95 ​% CI 1.12-6.51, P ​= ​0.03; aOR morbidly obese 6.94, 95 ​% CI 2.21-23.52, P ​= ​0.001] and average HR [aOR (per 10 bpm increase) 1.51, 95 ​% CI 1.21-1.9, P ​< ​0.001] were associated with the scoring of any segment as ​≤ ​3 ​at the patient level in a fully adjusted model, the improved phase 2 of the process change was not [aOR 1.61, 95 ​% CI 0.78-3.32].</p><p><strong>Conclusion: </strong>Implementation of an institutional process change utilizing prospective ECG-triggered dual-source end-systolic acquisition avoided the use of beta-blockers, significantly reduced patient appointment and scan times with acceptable diagnostic performance.</p>\",\"PeriodicalId\":94071,\"journal\":{\"name\":\"Journal of cardiovascular computed tomography\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cardiovascular computed tomography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jcct.2024.10.003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiovascular computed tomography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.jcct.2024.10.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导言:指南建议在达到最佳心率(HR)控制后进行前瞻性心电图触发的舒张中期冠状动脉计算机断层扫描(CCTA)采集,以优化扫描图像质量。在双源 CCTA 中,前瞻性收缩末期采集已被证明在心率较高时不易出现运动伪影,而且可以在扫描前不常规使用β-受体阻滞剂(BB),从而提高扫描和 CT 实验室的效率:我们从 2023 年 1 月起对 CCTA 性能实施了机构流程改革,包括从由医生在扫描仪旁单独监督的前瞻性心电图触发舒张中期采集过渡到主要利用前瞻性收缩末期采集(R 峰后 200-400 毫秒)的算法方法,该方法采用自动剂量选择算法,无需使用β-受体阻滞剂。所有扫描均在第三代 192 片双源扫描仪上进行。我们对 2022 年 1 月(第 0 阶段)、2023 年 1 月(第 1 阶段)和 2023 年 5 月(第 2 阶段)连续进行的 300 例 CCTAs 进行了流程变更前后的审查,流程变更后,我们将更有选择性地使用自动管电位/电流算法(CARE kV)来优化图像质量。冠状动脉节段图像质量由两名经验丰富的 CCTA 阅读者使用 18 节段 SCCT 模型以 5 点李克特量表(1 = 无法解读;2 = 差;3 = 可接受;4 = 好;5 = 极佳)一致评估。对辐射剂量、用药量和患者扫描所需时间进行了比较。采用逻辑回归法确定与患者图像质量(IQ)下降和重复扫描相关的因素:结果:流程改变后,患者预约时间的中位数明显减少[第 0 阶段:95 (75-125) 分钟;第 1 阶段:68 (52-88) 分钟;第 2 阶段:72 (59-90) 分钟;P 结论:流程改变后,患者预约时间的中位数明显减少:利用前瞻性心电图触发双源收缩末期采集实施机构流程变革,避免了β-受体阻滞剂的使用,显著缩短了患者预约时间和扫描时间,且诊断效果可接受。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of an institutional process change adopting end-systolic coronary CTA acquisition and automated dose selection on patient throughput and image quality.

Introduction: Guidelines recommend prospective ECG-triggered mid-diastolic coronary computed tomographic angiography (CCTA) acquisition after achieving optimal heart rate (HR) control in order to optimize scan image quality. With dual-source CCTA, prospective end-systolic acquisition has been shown to be less prone to motion artifacts at higher heart rates and may improve scan and CT laboratory efficiency by allowing CCTA without routine pre-scan beta-blocker (BB) administration.

Methods: We implemented an institutional process change in CCTA performance effective January 2023, comprising a transition from prospective ECG-triggered mid-diastolic acquisitions individually supervised by a physician at the scanner to an algorithmic approach predominately utilizing prospective end-systolic acquisition (200-400 ​ms after R peak), employing an automated dose selection algorithm, without BB administration. All scans were performed on a third-generation 192-slice dual-source scanner. We reviewed 300 consecutive CCTAs done pre- and post-process change in Jan 2022 (phase 0), Jan 2023 (phase 1), and in May 2023 (phase 2) after implementation of a process improvement involving more selective utilization of automated tube potential/current algorithms (CARE kV) to optimize image quality. Coronary segmental image quality was assessed by two experienced CCTA readers by consensus using an 18-segment SCCT model on a 5-point Likert scale (1 ​= ​non-interpretable; 2 ​= ​poor; 3 ​= ​acceptable; 4 ​= ​good; 5 ​= ​excellent). Measures of radiation dose, medication administration, and time required for patient scanning were compared. Logistic regression was used to determine factors associated with patient-level reduction in image quality (IQ) and with repeat scans.

Results: Post-process change, there was a significant reduction in the median overall patient appointment [phase 0: 95 (75-125) min vs. phase 1: 68 (52-88) min and phase 2: 72 (59-90) min; P ​< ​0.001] and scan times [phase 0: 13 (10-16) min vs. phase 1: 8 (6-13) min and phase 2: 9 (7-13) min; P ​< ​0.001]. Median IQ score in both post-process change phases was 4 (4-5) compared to a median score of 5 (4-5) pre-process change (P for comparison <0.001). The majority of segments post-process change had "good" IQ (Phase 1 segmental IQ scores: 5 ​= ​36.7 ​%, 4 ​= ​46.8 ​%, 3 ​= ​13 ​%, 2 ​= ​2.6 ​%, 1 ​= ​0.9 ​%; Phase 2 segmental IQ scores: 5 ​= ​26 ​%, 4 ​= ​49.7 ​%, 3 ​= ​16.3 ​%, 2 ​= ​6.1 ​%, 1 ​= ​1.9 ​%), whereas pre-process change, the majority of segments had "excellent" IQ (Phase 0 segmental IQ scores: 5 ​= ​56 ​%, 4 ​= ​34.3 ​%, 3 ​= ​7.5 ​%, 2 ​= ​1.8 ​%, 1 ​= ​0.4 ​%) There was no significant increase in non-interpretable scans at the patient level. The 22 ​% re-scan rate in phase 1 (vs. 6 ​% in phase 0, P ​= ​.002) improved to 15 ​% in phase 2. While patient related factors of body mass index [adjusted OR obese 2.64, 95 ​% CI 1.12-6.51, P ​= ​0.03; aOR morbidly obese 6.94, 95 ​% CI 2.21-23.52, P ​= ​0.001] and average HR [aOR (per 10 bpm increase) 1.51, 95 ​% CI 1.21-1.9, P ​< ​0.001] were associated with the scoring of any segment as ​≤ ​3 ​at the patient level in a fully adjusted model, the improved phase 2 of the process change was not [aOR 1.61, 95 ​% CI 0.78-3.32].

Conclusion: Implementation of an institutional process change utilizing prospective ECG-triggered dual-source end-systolic acquisition avoided the use of beta-blockers, significantly reduced patient appointment and scan times with acceptable diagnostic performance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Highlights of the nineteenth annual scientific meeting of the society of cardiovascular computed tomography. Asessing the feasibility and accuracy of an on-site prototype workstation in assessing CT derived fractional flow reserve in severe aortic stenosis. Diagnostic performance of CCTA and CTP imaging for clinically suspected in-stent restenosis: A meta-analysis. Cost-effectiveness of ultrahigh-resolution photon-counting detector coronary CT angiography for the evaluation of stable chest pain. Association of coronary inflammation with plaque vulnerability and fractional flow reserve in coronary artery disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1