Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian
{"title":"经颈动脉血流逆转用于脑动脉瘤夹重建过程中的近端控制:示例病例。","authors":"Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian","doi":"10.3171/CASE24330","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.</p><p><strong>Observations: </strong>A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.</p><p><strong>Lessons: </strong>Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.</p>","PeriodicalId":94098,"journal":{"name":"Journal of neurosurgery. Case lessons","volume":"8 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488372/pdf/","citationCount":"0","resultStr":"{\"title\":\"Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.\",\"authors\":\"Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian\",\"doi\":\"10.3171/CASE24330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.</p><p><strong>Observations: </strong>A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.</p><p><strong>Lessons: </strong>Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.</p>\",\"PeriodicalId\":94098,\"journal\":{\"name\":\"Journal of neurosurgery. Case lessons\",\"volume\":\"8 16\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488372/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurosurgery. Case lessons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3171/CASE24330\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Case lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE24330","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.
Background: Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.
Observations: A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.
Lessons: Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.