压实松质骨异体移植物的微结构特性:形态学微型计算机断层扫描分析。

IF 3.3 2区 医学 Q2 ENGINEERING, BIOMEDICAL Journal of the Mechanical Behavior of Biomedical Materials Pub Date : 2024-10-15 DOI:10.1016/j.jmbbm.2024.106781
D. Putzer , J. Pallua , G. Degenhardt , D. Dammerer , M. Nogler , R. Arora
{"title":"压实松质骨异体移植物的微结构特性:形态学微型计算机断层扫描分析。","authors":"D. Putzer ,&nbsp;J. Pallua ,&nbsp;G. Degenhardt ,&nbsp;D. Dammerer ,&nbsp;M. Nogler ,&nbsp;R. Arora","doi":"10.1016/j.jmbbm.2024.106781","DOIUrl":null,"url":null,"abstract":"<div><div>Massive bone loss poses a significant challenge in defect reconstruction. The use of compacted allografts is a valuable technique to reconstruct bone stock. This study aimed to assess the impact of compression on the microstructure of native cancellous bone chips with a micro-CT analysis.</div><div>Bone samples were harvested from 15 femoral heads donated by patients who underwent total hip arthroplasty. Bone chips were prepared using a bone mill. All samples with the same weight were compressed by 25% and 50% of their original volume and subsequently scanned with a micro-CT scanner to determine the microarchitectural morphology of the bone chips. Uniaxial compression test was carried out before and after a standardized compaction procedure.</div><div>Comparing the samples without compaction to 50%, the number of trabeculae doubled, the volume ratio doubled, and the trabeculae spacing was reduced, showing voids of 800 μm on average. The number of interlocking possibilities tripled, while no differences were seen in the trabeculae morphology. Uniaxial compression test showed a yield limit after compaction of 0.125 MPa.</div><div>Interlocking might occur three times more with a denser material than in a non-compacted sample. The increase in density comparable to manual intraoperative compaction did not lead to significant fragmentation of the allograft material. The assessed microarchitecture should, therefore, reassemble the intraoperative situation during a manual bone impaction procedure.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"160 ","pages":"Article 106781"},"PeriodicalIF":3.3000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microarchitectural properties of compacted cancellous bone allografts: A morphology micro-computed tomography analysis\",\"authors\":\"D. Putzer ,&nbsp;J. Pallua ,&nbsp;G. Degenhardt ,&nbsp;D. Dammerer ,&nbsp;M. Nogler ,&nbsp;R. Arora\",\"doi\":\"10.1016/j.jmbbm.2024.106781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Massive bone loss poses a significant challenge in defect reconstruction. The use of compacted allografts is a valuable technique to reconstruct bone stock. This study aimed to assess the impact of compression on the microstructure of native cancellous bone chips with a micro-CT analysis.</div><div>Bone samples were harvested from 15 femoral heads donated by patients who underwent total hip arthroplasty. Bone chips were prepared using a bone mill. All samples with the same weight were compressed by 25% and 50% of their original volume and subsequently scanned with a micro-CT scanner to determine the microarchitectural morphology of the bone chips. Uniaxial compression test was carried out before and after a standardized compaction procedure.</div><div>Comparing the samples without compaction to 50%, the number of trabeculae doubled, the volume ratio doubled, and the trabeculae spacing was reduced, showing voids of 800 μm on average. The number of interlocking possibilities tripled, while no differences were seen in the trabeculae morphology. Uniaxial compression test showed a yield limit after compaction of 0.125 MPa.</div><div>Interlocking might occur three times more with a denser material than in a non-compacted sample. The increase in density comparable to manual intraoperative compaction did not lead to significant fragmentation of the allograft material. The assessed microarchitecture should, therefore, reassemble the intraoperative situation during a manual bone impaction procedure.</div></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":\"160 \",\"pages\":\"Article 106781\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616124004132\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124004132","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

大量骨质流失给缺损重建带来了巨大挑战。使用压缩同种异体骨是重建骨量的一项重要技术。本研究旨在通过显微 CT 分析评估压缩对原生松质骨片微观结构的影响。骨样本取自接受全髋关节置换术的患者捐赠的 15 个股骨头。使用骨研磨机制备骨片。将重量相同的所有样本分别压缩其原始体积的 25% 和 50%,然后用显微 CT 扫描仪进行扫描,以确定骨片的微观结构形态。在标准化压实程序前后进行了单轴压缩测试。与未压实至 50%的样品相比,骨小梁数量增加了一倍,体积比增加了一倍,骨小梁间距减小,平均空隙为 800 μm。交错可能性的数量增加了两倍,而小梁的形态却没有变化。单轴压缩试验显示,压实后的屈服极限为 0.125 兆帕。与未经压实的样品相比,密度更大的材料发生交错的可能性要高出三倍。与术中人工压实相当的密度增加并不会导致同种异体移植材料明显破碎。因此,所评估的微观结构应能重现人工骨压实过程中的术中情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microarchitectural properties of compacted cancellous bone allografts: A morphology micro-computed tomography analysis
Massive bone loss poses a significant challenge in defect reconstruction. The use of compacted allografts is a valuable technique to reconstruct bone stock. This study aimed to assess the impact of compression on the microstructure of native cancellous bone chips with a micro-CT analysis.
Bone samples were harvested from 15 femoral heads donated by patients who underwent total hip arthroplasty. Bone chips were prepared using a bone mill. All samples with the same weight were compressed by 25% and 50% of their original volume and subsequently scanned with a micro-CT scanner to determine the microarchitectural morphology of the bone chips. Uniaxial compression test was carried out before and after a standardized compaction procedure.
Comparing the samples without compaction to 50%, the number of trabeculae doubled, the volume ratio doubled, and the trabeculae spacing was reduced, showing voids of 800 μm on average. The number of interlocking possibilities tripled, while no differences were seen in the trabeculae morphology. Uniaxial compression test showed a yield limit after compaction of 0.125 MPa.
Interlocking might occur three times more with a denser material than in a non-compacted sample. The increase in density comparable to manual intraoperative compaction did not lead to significant fragmentation of the allograft material. The assessed microarchitecture should, therefore, reassemble the intraoperative situation during a manual bone impaction procedure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
期刊最新文献
Macroscopic creep behavior of spheroids derived from mesenchymal stem cells under compression Sequential irradiation does not improve fatigue crack propagation resistance of human cortical bone at 15 kGy Editorial Board Improving the processability and mechanical strength of self-hardening robocasted hydroxyapatite scaffolds with silane coupling agents Plastic strain localization in Bouligand structures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1