Julie L.V. Shaw, Raveendhara R. Bannuru, Lori Beach, Nuha A. ElSayed, Guido Freckmann, Anna K. Füzéry, Angela W.S. Fung, Jeremy Gilbert, Yun Huang, Nichole Korpi-Steiner, Samantha Logan, Rebecca Longo, Dylan MacKay, Lisa Maks, Stefan Pleus, Kendall Rogers, Jane Jeffrie Seley, Zachary Taxin, Fiona Thompson-Hutchison, Nicole V. Tolan, Nam K. Tran, Guillermo E. Umpierrez, Allison A. Venner
{"title":"在医院环境中使用连续血糖监测系统的共识考虑因素和良好操作要点","authors":"Julie L.V. Shaw, Raveendhara R. Bannuru, Lori Beach, Nuha A. ElSayed, Guido Freckmann, Anna K. Füzéry, Angela W.S. Fung, Jeremy Gilbert, Yun Huang, Nichole Korpi-Steiner, Samantha Logan, Rebecca Longo, Dylan MacKay, Lisa Maks, Stefan Pleus, Kendall Rogers, Jane Jeffrie Seley, Zachary Taxin, Fiona Thompson-Hutchison, Nicole V. Tolan, Nam K. Tran, Guillermo E. Umpierrez, Allison A. Venner","doi":"10.2337/dci24-0073","DOIUrl":null,"url":null,"abstract":"Continuous glucose monitoring (CGM) systems provide frequent glucose measurements in interstitial fluid and have been used widely in ambulatory settings for diabetes management. During the coronavirus disease 2019 (COVID-19) pandemic, regulators in the U.S. and Canada temporarily allowed for CGM systems to be used in hospitals with the aim of reducing health care professional COVID-19 exposure and limiting use of personal protective equipment. As such, studies on hospital CGM system use have been possible. With improved sensor accuracy, there is increased interest in CGM usage for diabetes management in hospitals. Laboratorians and health care professionals must determine how to integrate CGM usage into practice. The aim of this consensus guidance document is to provide an update on the application of CGM systems in hospital, with insights and opinions from laboratory medicine, endocrinology, and nursing.","PeriodicalId":11140,"journal":{"name":"Diabetes Care","volume":null,"pages":null},"PeriodicalIF":14.8000,"publicationDate":"2024-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Consensus Considerations and Good Practice Points for Use of Continuous Glucose Monitoring Systems in Hospital Settings\",\"authors\":\"Julie L.V. Shaw, Raveendhara R. Bannuru, Lori Beach, Nuha A. ElSayed, Guido Freckmann, Anna K. Füzéry, Angela W.S. Fung, Jeremy Gilbert, Yun Huang, Nichole Korpi-Steiner, Samantha Logan, Rebecca Longo, Dylan MacKay, Lisa Maks, Stefan Pleus, Kendall Rogers, Jane Jeffrie Seley, Zachary Taxin, Fiona Thompson-Hutchison, Nicole V. Tolan, Nam K. Tran, Guillermo E. Umpierrez, Allison A. Venner\",\"doi\":\"10.2337/dci24-0073\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Continuous glucose monitoring (CGM) systems provide frequent glucose measurements in interstitial fluid and have been used widely in ambulatory settings for diabetes management. During the coronavirus disease 2019 (COVID-19) pandemic, regulators in the U.S. and Canada temporarily allowed for CGM systems to be used in hospitals with the aim of reducing health care professional COVID-19 exposure and limiting use of personal protective equipment. As such, studies on hospital CGM system use have been possible. With improved sensor accuracy, there is increased interest in CGM usage for diabetes management in hospitals. Laboratorians and health care professionals must determine how to integrate CGM usage into practice. The aim of this consensus guidance document is to provide an update on the application of CGM systems in hospital, with insights and opinions from laboratory medicine, endocrinology, and nursing.\",\"PeriodicalId\":11140,\"journal\":{\"name\":\"Diabetes Care\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":14.8000,\"publicationDate\":\"2024-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2337/dci24-0073\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2337/dci24-0073","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Consensus Considerations and Good Practice Points for Use of Continuous Glucose Monitoring Systems in Hospital Settings
Continuous glucose monitoring (CGM) systems provide frequent glucose measurements in interstitial fluid and have been used widely in ambulatory settings for diabetes management. During the coronavirus disease 2019 (COVID-19) pandemic, regulators in the U.S. and Canada temporarily allowed for CGM systems to be used in hospitals with the aim of reducing health care professional COVID-19 exposure and limiting use of personal protective equipment. As such, studies on hospital CGM system use have been possible. With improved sensor accuracy, there is increased interest in CGM usage for diabetes management in hospitals. Laboratorians and health care professionals must determine how to integrate CGM usage into practice. The aim of this consensus guidance document is to provide an update on the application of CGM systems in hospital, with insights and opinions from laboratory medicine, endocrinology, and nursing.
期刊介绍:
The journal's overarching mission can be captured by the simple word "Care," reflecting its commitment to enhancing patient well-being. Diabetes Care aims to support better patient care by addressing the comprehensive needs of healthcare professionals dedicated to managing diabetes.
Diabetes Care serves as a valuable resource for healthcare practitioners, aiming to advance knowledge, foster research, and improve diabetes management. The journal publishes original research across various categories, including Clinical Care, Education, Nutrition, Psychosocial Research, Epidemiology, Health Services Research, Emerging Treatments and Technologies, Pathophysiology, Complications, and Cardiovascular and Metabolic Risk. Additionally, Diabetes Care features ADA statements, consensus reports, review articles, letters to the editor, and health/medical news, appealing to a diverse audience of physicians, researchers, psychologists, educators, and other healthcare professionals.