上腔静脉塌陷指数作为输液反应性的预测指标:系统综述与荟萃分析。

IF 1.6 Q2 ANESTHESIOLOGY Anaesthesiology intensive therapy Pub Date : 2024-01-01 DOI:10.5114/ait.2024.142797
Tomasz Królicki, Maciej Molsa, Andrzej Tukiendorf, Ryszard Gawda, Tomasz Czarnik
{"title":"上腔静脉塌陷指数作为输液反应性的预测指标:系统综述与荟萃分析。","authors":"Tomasz Królicki, Maciej Molsa, Andrzej Tukiendorf, Ryszard Gawda, Tomasz Czarnik","doi":"10.5114/ait.2024.142797","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The superior vena cava collapsibility index (SVC-CI) is a potential marker of fluid responsiveness (FR) in mechanically ventilated patients. Few studies reporting its diagnostic performance are currently available.</p><p><strong>Material and methods: </strong>A systematic search, using the PRISMA approach, was performed using the Medline and EMBASE databases. Prospective studies evaluating the SVC-CI as a marker of FR in ventilated adult patients were included. A bivariate random-effect model was utilised to generate the summary receiver operating characteristic (SROC) curve. The area under the ROC curve (AUC), the sensitivity and specificity of the curve operating point were calculated.</p><p><strong>Results: </strong>We included eight studies with a total of 857 patients, in whom SVC-CI was evaluated a total of 1083 times prior to the volume expansion trial. In 609 (56.23%) trial cases FR was present. The SROC curve demonstrated that the test's operating point has a sensitivity and specificity of 80.8% (95% CI: 66.3-90%) and 81.4% (95% CI: 76.4-85.5%), respectively. The model's AUC was equal to 0.848 (95% CI: 0.824-0.863) with P < 0.001. No significant inter-study heterogeneity was found (I 2 = 0%). A subgroup analysis revealed a significantly lower sensitivity of SVC-CI in patients with higher levels of positive end-expiratory pressure (PEEP) (> 5 cm H 2 O) (χ 2 = 7.753, df = 2, P = 0.0207). The study setting and type of intervention for volume expansion did not significantly change the performance of the test.</p><p><strong>Conclusions: </strong>SVC-CI is a reliable predictor of FR for mechanically ventilated patients in intensive care units and operating rooms. A PEEP level exceeding 5 cm H 2 O may impair the sensitivity of the test.</p>","PeriodicalId":7750,"journal":{"name":"Anaesthesiology intensive therapy","volume":"56 3","pages":"169-176"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11484487/pdf/","citationCount":"0","resultStr":"{\"title\":\"Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis.\",\"authors\":\"Tomasz Królicki, Maciej Molsa, Andrzej Tukiendorf, Ryszard Gawda, Tomasz Czarnik\",\"doi\":\"10.5114/ait.2024.142797\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The superior vena cava collapsibility index (SVC-CI) is a potential marker of fluid responsiveness (FR) in mechanically ventilated patients. Few studies reporting its diagnostic performance are currently available.</p><p><strong>Material and methods: </strong>A systematic search, using the PRISMA approach, was performed using the Medline and EMBASE databases. Prospective studies evaluating the SVC-CI as a marker of FR in ventilated adult patients were included. A bivariate random-effect model was utilised to generate the summary receiver operating characteristic (SROC) curve. The area under the ROC curve (AUC), the sensitivity and specificity of the curve operating point were calculated.</p><p><strong>Results: </strong>We included eight studies with a total of 857 patients, in whom SVC-CI was evaluated a total of 1083 times prior to the volume expansion trial. In 609 (56.23%) trial cases FR was present. The SROC curve demonstrated that the test's operating point has a sensitivity and specificity of 80.8% (95% CI: 66.3-90%) and 81.4% (95% CI: 76.4-85.5%), respectively. The model's AUC was equal to 0.848 (95% CI: 0.824-0.863) with P < 0.001. No significant inter-study heterogeneity was found (I 2 = 0%). A subgroup analysis revealed a significantly lower sensitivity of SVC-CI in patients with higher levels of positive end-expiratory pressure (PEEP) (> 5 cm H 2 O) (χ 2 = 7.753, df = 2, P = 0.0207). The study setting and type of intervention for volume expansion did not significantly change the performance of the test.</p><p><strong>Conclusions: </strong>SVC-CI is a reliable predictor of FR for mechanically ventilated patients in intensive care units and operating rooms. A PEEP level exceeding 5 cm H 2 O may impair the sensitivity of the test.</p>\",\"PeriodicalId\":7750,\"journal\":{\"name\":\"Anaesthesiology intensive therapy\",\"volume\":\"56 3\",\"pages\":\"169-176\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11484487/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesiology intensive therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/ait.2024.142797\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesiology intensive therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/ait.2024.142797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

简介:上腔静脉塌陷指数(SVC-CI)是机械通气患者液体反应性(FR)的潜在标志。目前报告其诊断性能的研究很少:采用 PRISMA 方法,在 Medline 和 EMBASE 数据库中进行了系统检索。研究纳入了将 SVC-CI 作为通气成人患者 FR 标记的前瞻性研究。利用双变量随机效应模型生成了接收者操作特征曲线(SROC)。计算了 ROC 曲线下面积(AUC)、曲线工作点的灵敏度和特异性:我们纳入了八项研究,共有 857 名患者,在扩容试验前共对其进行了 1083 次 SVC-CI 评估。在 609 例(56.23%)试验病例中存在 FR。SROC 曲线显示,该检验的工作点灵敏度和特异度分别为 80.8%(95% CI:66.3-90%)和 81.4%(95% CI:76.4-85.5%)。模型的 AUC 等于 0.848(95% CI:0.824-0.863),P < 0.001。没有发现明显的研究间异质性(I 2 = 0%)。亚组分析显示,呼气末正压(PEEP)水平较高(> 5 cm H 2 O)的患者的 SVC-CI 敏感性明显较低(χ 2 = 7.753,df = 2,P = 0.0207)。研究环境和扩容干预类型对测试结果没有明显影响:结论:SVC-CI 是重症监护室和手术室机械通气患者 FR 的可靠预测指标。PEEP 水平超过 5 cm H 2 O 可能会影响测试的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis.

Introduction: The superior vena cava collapsibility index (SVC-CI) is a potential marker of fluid responsiveness (FR) in mechanically ventilated patients. Few studies reporting its diagnostic performance are currently available.

Material and methods: A systematic search, using the PRISMA approach, was performed using the Medline and EMBASE databases. Prospective studies evaluating the SVC-CI as a marker of FR in ventilated adult patients were included. A bivariate random-effect model was utilised to generate the summary receiver operating characteristic (SROC) curve. The area under the ROC curve (AUC), the sensitivity and specificity of the curve operating point were calculated.

Results: We included eight studies with a total of 857 patients, in whom SVC-CI was evaluated a total of 1083 times prior to the volume expansion trial. In 609 (56.23%) trial cases FR was present. The SROC curve demonstrated that the test's operating point has a sensitivity and specificity of 80.8% (95% CI: 66.3-90%) and 81.4% (95% CI: 76.4-85.5%), respectively. The model's AUC was equal to 0.848 (95% CI: 0.824-0.863) with P < 0.001. No significant inter-study heterogeneity was found (I 2 = 0%). A subgroup analysis revealed a significantly lower sensitivity of SVC-CI in patients with higher levels of positive end-expiratory pressure (PEEP) (> 5 cm H 2 O) (χ 2 = 7.753, df = 2, P = 0.0207). The study setting and type of intervention for volume expansion did not significantly change the performance of the test.

Conclusions: SVC-CI is a reliable predictor of FR for mechanically ventilated patients in intensive care units and operating rooms. A PEEP level exceeding 5 cm H 2 O may impair the sensitivity of the test.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
5.90%
发文量
48
审稿时长
25 weeks
期刊最新文献
A randomised controlled trial to compare blind intubation success through LMA Blockbuster® and I-Gel® LMA. Can't intubate, can't oxygenate? What is the preferred surgical strategy? A retrospective analysis. Measures of preoperative anxiety: Part two. Navigating through the paradox of choice: prediction of outcome in aneurysmal subarachnoid hemorrhage. Nutritional management in critically ill patients with COVID-19: a retrospective multicentre study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1