Han Ma, Wei Wang, Na Dong, Jiali Liu, Shuai Yuan, Chuanbao Zhang, Chao Zhang, Jie Zeng, Ying Yan, Zhiguo Wang
{"title":"2015-2023年中国血铅内部质量控制状况的变异系数分析。","authors":"Han Ma, Wei Wang, Na Dong, Jiali Liu, Shuai Yuan, Chuanbao Zhang, Chao Zhang, Jie Zeng, Ying Yan, Zhiguo Wang","doi":"10.1177/00045632241297885","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Blood lead test is widely conducted in Chinese laboratories, while the imprecision of blood lead measurement based on internal quality control (IQC) across China has not been comprehensively evaluated nowadays.</p><p><strong>Methods: </strong>Using the IQC data of blood lead collected through a web-based external quality assessment (EQA) reporting system, we analysed current coefficients of variation (CVs) of blood lead from 2015 to 2023 among Chinese laboratories. Two allowable total error (TEa) imprecision levels from EQA were applied to calculate the pass rates, namely percentages of laboratories meeting precision quality specifications. Besides, CV values and pass rates by different subgroups were further performed to assess potential differences.</p><p><strong>Results: </strong>Generally, median CV values significantly declined year by year from 6.8% in February 2015 to 5.9% in March 2023. The pass rates based on 1/3 TEa showed upward trends increasing from 15.3% in February 2015 to 20.0% in March 2023, but these percentages were non-ideal with less than 25%. No significant differences in CVs were found between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Significant time trends were observed in tertiary hospitals and non-accredited laboratories. As for manufacturers, Bohui and self-made QC sample were most widely used with obvious interannual declining trends of CVs.</p><p><strong>Conclusions: </strong>The CVs of blood lead demonstrated continuous overall improvements in the past twenty years. However, relatively lower pass rates indicated the non-ideal imprecision performance, and more proper performance specifications are warranted. Thus, imprecision improvement and ongoing investigation for blood lead IQC are still needed.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"45632241297885"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coefficients of variation analyses of internal quality control status for blood lead in China from 2015 to 2023.\",\"authors\":\"Han Ma, Wei Wang, Na Dong, Jiali Liu, Shuai Yuan, Chuanbao Zhang, Chao Zhang, Jie Zeng, Ying Yan, Zhiguo Wang\",\"doi\":\"10.1177/00045632241297885\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Blood lead test is widely conducted in Chinese laboratories, while the imprecision of blood lead measurement based on internal quality control (IQC) across China has not been comprehensively evaluated nowadays.</p><p><strong>Methods: </strong>Using the IQC data of blood lead collected through a web-based external quality assessment (EQA) reporting system, we analysed current coefficients of variation (CVs) of blood lead from 2015 to 2023 among Chinese laboratories. Two allowable total error (TEa) imprecision levels from EQA were applied to calculate the pass rates, namely percentages of laboratories meeting precision quality specifications. Besides, CV values and pass rates by different subgroups were further performed to assess potential differences.</p><p><strong>Results: </strong>Generally, median CV values significantly declined year by year from 6.8% in February 2015 to 5.9% in March 2023. The pass rates based on 1/3 TEa showed upward trends increasing from 15.3% in February 2015 to 20.0% in March 2023, but these percentages were non-ideal with less than 25%. No significant differences in CVs were found between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Significant time trends were observed in tertiary hospitals and non-accredited laboratories. As for manufacturers, Bohui and self-made QC sample were most widely used with obvious interannual declining trends of CVs.</p><p><strong>Conclusions: </strong>The CVs of blood lead demonstrated continuous overall improvements in the past twenty years. However, relatively lower pass rates indicated the non-ideal imprecision performance, and more proper performance specifications are warranted. Thus, imprecision improvement and ongoing investigation for blood lead IQC are still needed.</p>\",\"PeriodicalId\":8005,\"journal\":{\"name\":\"Annals of Clinical Biochemistry\",\"volume\":\" \",\"pages\":\"45632241297885\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Clinical Biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00045632241297885\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632241297885","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Coefficients of variation analyses of internal quality control status for blood lead in China from 2015 to 2023.
Background: Blood lead test is widely conducted in Chinese laboratories, while the imprecision of blood lead measurement based on internal quality control (IQC) across China has not been comprehensively evaluated nowadays.
Methods: Using the IQC data of blood lead collected through a web-based external quality assessment (EQA) reporting system, we analysed current coefficients of variation (CVs) of blood lead from 2015 to 2023 among Chinese laboratories. Two allowable total error (TEa) imprecision levels from EQA were applied to calculate the pass rates, namely percentages of laboratories meeting precision quality specifications. Besides, CV values and pass rates by different subgroups were further performed to assess potential differences.
Results: Generally, median CV values significantly declined year by year from 6.8% in February 2015 to 5.9% in March 2023. The pass rates based on 1/3 TEa showed upward trends increasing from 15.3% in February 2015 to 20.0% in March 2023, but these percentages were non-ideal with less than 25%. No significant differences in CVs were found between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Significant time trends were observed in tertiary hospitals and non-accredited laboratories. As for manufacturers, Bohui and self-made QC sample were most widely used with obvious interannual declining trends of CVs.
Conclusions: The CVs of blood lead demonstrated continuous overall improvements in the past twenty years. However, relatively lower pass rates indicated the non-ideal imprecision performance, and more proper performance specifications are warranted. Thus, imprecision improvement and ongoing investigation for blood lead IQC are still needed.
期刊介绍:
Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine.
Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals.
Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).