{"title":"灌注流速对病灶大小和消融导管安全性的影响:猪心脏体外研究。","authors":"Morio Ono, Takamasa Ishikawa, Yui Koyanagi, Yuma Gibo, Soichiro Usumoto, Jumpei Saito, Toshihiko Gokan, Toshitaka Okabe, Naoei Isomura, Mitunori Muto, Masaru Shiigai, Jyunko Hone, Masahiko Ochiai","doi":"10.1007/s00380-024-02475-6","DOIUrl":null,"url":null,"abstract":"<p><p>Radiofrequency (RF) catheter ablation is a well-established therapeutic approach for treating arrhythmias, where lesion size and safety are critical for efficacy. This study explored the impact of varying irrigation flow rates on lesion characteristics using the TactiFlex™ SE Ablation Catheter (TF) in an ex vivo porcine heart model, focusing on the size and safety outcomes associated with low versus standard flow rates. Myocardial slabs from porcine hearts were subjected to ablation using two types of irrigated catheters. Lesion formation was compared between low (8 mL/min for TF) and standard irrigation flow rates (13 mL/min for TF) across different power settings (30, 40, and 50 W). Outcome measures included lesion dimensions, incidence of steam pops, and impedance drops. A total of 210 lesions were generated under various settings. At low flow rates, the TF catheter safely formed larger lesions compared to the standard flow rates without a significant increase in steam pops or impedance drops. Lesions at low flow rates were comparable in size to those formed using other catheters under the standard settings. Conversely, the standard flow settings for TF produced smaller lesions but exhibited higher safety profiles, as evidenced by fewer steam pops and impedance drops. Lower irrigation flow rates using a TF catheter can achieve larger lesions without compromising safety, offering an optimization strategy for RF ablation procedures that balances efficacy and safety. These findings may guide clinicians in tailoring ablation strategies according to individual patient needs.</p>","PeriodicalId":12940,"journal":{"name":"Heart and Vessels","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of irrigation flow rates on lesion size and safety of ablation catheters: an ex vivo porcine heart study.\",\"authors\":\"Morio Ono, Takamasa Ishikawa, Yui Koyanagi, Yuma Gibo, Soichiro Usumoto, Jumpei Saito, Toshihiko Gokan, Toshitaka Okabe, Naoei Isomura, Mitunori Muto, Masaru Shiigai, Jyunko Hone, Masahiko Ochiai\",\"doi\":\"10.1007/s00380-024-02475-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Radiofrequency (RF) catheter ablation is a well-established therapeutic approach for treating arrhythmias, where lesion size and safety are critical for efficacy. This study explored the impact of varying irrigation flow rates on lesion characteristics using the TactiFlex™ SE Ablation Catheter (TF) in an ex vivo porcine heart model, focusing on the size and safety outcomes associated with low versus standard flow rates. Myocardial slabs from porcine hearts were subjected to ablation using two types of irrigated catheters. Lesion formation was compared between low (8 mL/min for TF) and standard irrigation flow rates (13 mL/min for TF) across different power settings (30, 40, and 50 W). Outcome measures included lesion dimensions, incidence of steam pops, and impedance drops. A total of 210 lesions were generated under various settings. At low flow rates, the TF catheter safely formed larger lesions compared to the standard flow rates without a significant increase in steam pops or impedance drops. Lesions at low flow rates were comparable in size to those formed using other catheters under the standard settings. Conversely, the standard flow settings for TF produced smaller lesions but exhibited higher safety profiles, as evidenced by fewer steam pops and impedance drops. Lower irrigation flow rates using a TF catheter can achieve larger lesions without compromising safety, offering an optimization strategy for RF ablation procedures that balances efficacy and safety. These findings may guide clinicians in tailoring ablation strategies according to individual patient needs.</p>\",\"PeriodicalId\":12940,\"journal\":{\"name\":\"Heart and Vessels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart and Vessels\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00380-024-02475-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart and Vessels","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00380-024-02475-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Impact of irrigation flow rates on lesion size and safety of ablation catheters: an ex vivo porcine heart study.
Radiofrequency (RF) catheter ablation is a well-established therapeutic approach for treating arrhythmias, where lesion size and safety are critical for efficacy. This study explored the impact of varying irrigation flow rates on lesion characteristics using the TactiFlex™ SE Ablation Catheter (TF) in an ex vivo porcine heart model, focusing on the size and safety outcomes associated with low versus standard flow rates. Myocardial slabs from porcine hearts were subjected to ablation using two types of irrigated catheters. Lesion formation was compared between low (8 mL/min for TF) and standard irrigation flow rates (13 mL/min for TF) across different power settings (30, 40, and 50 W). Outcome measures included lesion dimensions, incidence of steam pops, and impedance drops. A total of 210 lesions were generated under various settings. At low flow rates, the TF catheter safely formed larger lesions compared to the standard flow rates without a significant increase in steam pops or impedance drops. Lesions at low flow rates were comparable in size to those formed using other catheters under the standard settings. Conversely, the standard flow settings for TF produced smaller lesions but exhibited higher safety profiles, as evidenced by fewer steam pops and impedance drops. Lower irrigation flow rates using a TF catheter can achieve larger lesions without compromising safety, offering an optimization strategy for RF ablation procedures that balances efficacy and safety. These findings may guide clinicians in tailoring ablation strategies according to individual patient needs.
期刊介绍:
Heart and Vessels is an English-language journal that provides a forum of original ideas, excellent methods, and fascinating techniques on cardiovascular disease fields. All papers submitted for publication are evaluated only with regard to scientific quality and relevance to the heart and vessels. Contributions from those engaged in practical medicine, as well as from those involved in basic research, are welcomed.