Jiachen Liu, Zihan Ning, Chenlin Du, Shuo Chen, Tao Wang, Jingli Cao, Ran Huo, Dongye Li, Dandan Yang, Rui Shen, Shuwan Yu, Chunjiang Hu, Shuhao Wang, Huiyu Qiao, Xihai Zhao
{"title":"三维可变翻转角 TSE 多对比磁共振血管壁成像在确定颈动脉易动脉粥样硬化斑块特征方面的组织学验证","authors":"Jiachen Liu, Zihan Ning, Chenlin Du, Shuo Chen, Tao Wang, Jingli Cao, Ran Huo, Dongye Li, Dandan Yang, Rui Shen, Shuwan Yu, Chunjiang Hu, Shuhao Wang, Huiyu Qiao, Xihai Zhao","doi":"10.1016/j.jocmr.2024.101112","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate assessment of the vulnerability of carotid atherosclerotic plaques is crucial for stroke prevention. The three-dimensional (3D) magnetic resonance (MR) vessel wall imaging (VWI) has been increasingly employed to evaluate carotid plaques due to its extensive coverage and isotropic high spatial resolution. However, the accuracy of such technique lacks validation by histology.</p><p><strong>Objective: </strong>This study aims to validate the accuracy of 3D multi-contrast MR VWI used variable-flip-angle (VFA) and turbo spin echo (TSE) readout in identifying vulnerable carotid plaques, using histological analysis as a reference.</p><p><strong>Methods: </strong>Twenty-one male patients (mean age: 64.4 ± 7.2 years) scheduled for carotid endarterectomy (CEA) were recruited for this study. All patients underwent carotid multi-contrast MR VWI, including 3D T1- and T2-weighted variable flip angle-based turbo spin echo (VFA-TSE) sequences, as well as 3D time of flight (TOF) MR angiography (MRA), using a 3.0T MR system. Histological processing was performed for carotid plaque specimens. The presence or absence, along with the area measurements, of lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and calcifications (CA) were independently evaluated on both MR images and histological sections. Cohen's kappa (κ) analysis was utilized to determine the agreement between 3D multi-contrast MR VWI and histology in identifying carotid plaque compositions before and after excluding compositions bellow certain size threshold. Spearman's correlation analysis was also conducted to assess the agreement in quantifying plaque compositions.</p><p><strong>Results: </strong>A total of 81 slices of MR images were successfully matched with histological sections. Moderate to almost perfect agreements were observed between 3D MR VWI and histology in the identification of LRNC (κ: 0.85 and 0.89), IPH (κ: 0.65 and 0.69), and CA (κ: 0.46 and 0.62) before and after excluding compositions smaller than 0.79 mm<sup>2</sup>. Strong to very strong correlations were found in the quantification of plaque compositions including LRNC (r=0.88), IPH (r=0.80), and CA (r=0.74) between MR imaging and histology.</p><p><strong>Conclusion: </strong>The 3D VFA-TSE multi-contrast MR VWI is capable of accurately characterizing vulnerable carotid atherosclerotic plaques.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101112"},"PeriodicalIF":4.2000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Histological Validation of 3D Variable Flip Angle TSE Multi-Contrast Magnetic Resonance Vessel Wall Imaging in Characterizing Carotid Vulnerable Atherosclerotic Plaques.\",\"authors\":\"Jiachen Liu, Zihan Ning, Chenlin Du, Shuo Chen, Tao Wang, Jingli Cao, Ran Huo, Dongye Li, Dandan Yang, Rui Shen, Shuwan Yu, Chunjiang Hu, Shuhao Wang, Huiyu Qiao, Xihai Zhao\",\"doi\":\"10.1016/j.jocmr.2024.101112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Accurate assessment of the vulnerability of carotid atherosclerotic plaques is crucial for stroke prevention. The three-dimensional (3D) magnetic resonance (MR) vessel wall imaging (VWI) has been increasingly employed to evaluate carotid plaques due to its extensive coverage and isotropic high spatial resolution. However, the accuracy of such technique lacks validation by histology.</p><p><strong>Objective: </strong>This study aims to validate the accuracy of 3D multi-contrast MR VWI used variable-flip-angle (VFA) and turbo spin echo (TSE) readout in identifying vulnerable carotid plaques, using histological analysis as a reference.</p><p><strong>Methods: </strong>Twenty-one male patients (mean age: 64.4 ± 7.2 years) scheduled for carotid endarterectomy (CEA) were recruited for this study. All patients underwent carotid multi-contrast MR VWI, including 3D T1- and T2-weighted variable flip angle-based turbo spin echo (VFA-TSE) sequences, as well as 3D time of flight (TOF) MR angiography (MRA), using a 3.0T MR system. Histological processing was performed for carotid plaque specimens. The presence or absence, along with the area measurements, of lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and calcifications (CA) were independently evaluated on both MR images and histological sections. Cohen's kappa (κ) analysis was utilized to determine the agreement between 3D multi-contrast MR VWI and histology in identifying carotid plaque compositions before and after excluding compositions bellow certain size threshold. Spearman's correlation analysis was also conducted to assess the agreement in quantifying plaque compositions.</p><p><strong>Results: </strong>A total of 81 slices of MR images were successfully matched with histological sections. Moderate to almost perfect agreements were observed between 3D MR VWI and histology in the identification of LRNC (κ: 0.85 and 0.89), IPH (κ: 0.65 and 0.69), and CA (κ: 0.46 and 0.62) before and after excluding compositions smaller than 0.79 mm<sup>2</sup>. Strong to very strong correlations were found in the quantification of plaque compositions including LRNC (r=0.88), IPH (r=0.80), and CA (r=0.74) between MR imaging and histology.</p><p><strong>Conclusion: </strong>The 3D VFA-TSE multi-contrast MR VWI is capable of accurately characterizing vulnerable carotid atherosclerotic plaques.</p>\",\"PeriodicalId\":15221,\"journal\":{\"name\":\"Journal of Cardiovascular Magnetic Resonance\",\"volume\":\" \",\"pages\":\"101112\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Magnetic Resonance\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jocmr.2024.101112\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2024.101112","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Histological Validation of 3D Variable Flip Angle TSE Multi-Contrast Magnetic Resonance Vessel Wall Imaging in Characterizing Carotid Vulnerable Atherosclerotic Plaques.
Background: Accurate assessment of the vulnerability of carotid atherosclerotic plaques is crucial for stroke prevention. The three-dimensional (3D) magnetic resonance (MR) vessel wall imaging (VWI) has been increasingly employed to evaluate carotid plaques due to its extensive coverage and isotropic high spatial resolution. However, the accuracy of such technique lacks validation by histology.
Objective: This study aims to validate the accuracy of 3D multi-contrast MR VWI used variable-flip-angle (VFA) and turbo spin echo (TSE) readout in identifying vulnerable carotid plaques, using histological analysis as a reference.
Methods: Twenty-one male patients (mean age: 64.4 ± 7.2 years) scheduled for carotid endarterectomy (CEA) were recruited for this study. All patients underwent carotid multi-contrast MR VWI, including 3D T1- and T2-weighted variable flip angle-based turbo spin echo (VFA-TSE) sequences, as well as 3D time of flight (TOF) MR angiography (MRA), using a 3.0T MR system. Histological processing was performed for carotid plaque specimens. The presence or absence, along with the area measurements, of lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and calcifications (CA) were independently evaluated on both MR images and histological sections. Cohen's kappa (κ) analysis was utilized to determine the agreement between 3D multi-contrast MR VWI and histology in identifying carotid plaque compositions before and after excluding compositions bellow certain size threshold. Spearman's correlation analysis was also conducted to assess the agreement in quantifying plaque compositions.
Results: A total of 81 slices of MR images were successfully matched with histological sections. Moderate to almost perfect agreements were observed between 3D MR VWI and histology in the identification of LRNC (κ: 0.85 and 0.89), IPH (κ: 0.65 and 0.69), and CA (κ: 0.46 and 0.62) before and after excluding compositions smaller than 0.79 mm2. Strong to very strong correlations were found in the quantification of plaque compositions including LRNC (r=0.88), IPH (r=0.80), and CA (r=0.74) between MR imaging and histology.
Conclusion: The 3D VFA-TSE multi-contrast MR VWI is capable of accurately characterizing vulnerable carotid atherosclerotic plaques.
期刊介绍:
Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to:
New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system.
New methods to enhance or accelerate image acquisition and data analysis.
Results of multicenter, or larger single-center studies that provide insight into the utility of CMR.
Basic biological perceptions derived by CMR methods.