开发和验证用于定量人血浆中来那度胺总量和未结合量的改进型 HPLC-MS/MS 方法

IF 4.9 3区 医学 Q1 PHARMACOLOGY & PHARMACY Pharmaceutics Pub Date : 2024-10-19 DOI:10.3390/pharmaceutics16101340
Suhyun Lee, Seungwon Yang, Wang-Seob Shim, Eunseo Song, Seunghoon Han, Sung-Soo Park, Suein Choi, Sung Hwan Joo, Seok Jun Park, Beomjin Shin, Donghyun Kim, Hyeonsu Kim, Yujung Jung, Kyung-Tae Lee, Eun Kyoung Chung
{"title":"开发和验证用于定量人血浆中来那度胺总量和未结合量的改进型 HPLC-MS/MS 方法","authors":"Suhyun Lee, Seungwon Yang, Wang-Seob Shim, Eunseo Song, Seunghoon Han, Sung-Soo Park, Suein Choi, Sung Hwan Joo, Seok Jun Park, Beomjin Shin, Donghyun Kim, Hyeonsu Kim, Yujung Jung, Kyung-Tae Lee, Eun Kyoung Chung","doi":"10.3390/pharmaceutics16101340","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>This study aimed to develop a fully validated HPLC-MS/MS method for quantifying total and unbound lenalidomide concentrations in human plasma.</p><p><strong>Methods: </strong>Unbound concentrations were measured using plasma ultrafiltrate prepared with Amicon<sup>®</sup> Centrifugal Filters. Lenalidomide and lenalidomide-d5 (internal standard) were extracted from 50 μL of human plasma using liquid-liquid extraction. Chromatography was conducted with a Halo<sup>®</sup> C18 column using 0.1% formic acid and methanol (20:80, <i>v</i>/<i>v</i>) as the mobile phase. The mass spectrometer was operated in a positive ion mode with an electrospray ionization interface and multiple reaction monitoring modes.</p><p><strong>Results: </strong>Calibration curves were linear over the range of 5 to 1000 ng/mL (r<sup>2</sup> > 0.996) for both the total and unbound lenalidomide. For total lenalidomide concentrations, between-run precision (coefficients of variation) and accuracy were 1.70-7.65% and 94.45-101.10%, respectively. For unbound concentrations, inter-day precision and accuracy were 1.98-10.55% and 93.95-98.48%, respectively.</p><p><strong>Conclusions: </strong>We developed a highly reproducible, sensitive, and efficient bioanalytical method using a smaller volume of plasma sample (50 μL) with a relatively short run time (2.5 min). The proposed analytical method was successfully applied to measure total and unbound lenalidomide concentrations at various time points in multiple myeloma patients with renal impairment.</p>","PeriodicalId":19894,"journal":{"name":"Pharmaceutics","volume":"16 10","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511013/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of an Improved HPLC-MS/MS Method for Quantifying Total and Unbound Lenalidomide in Human Plasma.\",\"authors\":\"Suhyun Lee, Seungwon Yang, Wang-Seob Shim, Eunseo Song, Seunghoon Han, Sung-Soo Park, Suein Choi, Sung Hwan Joo, Seok Jun Park, Beomjin Shin, Donghyun Kim, Hyeonsu Kim, Yujung Jung, Kyung-Tae Lee, Eun Kyoung Chung\",\"doi\":\"10.3390/pharmaceutics16101340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/objectives: </strong>This study aimed to develop a fully validated HPLC-MS/MS method for quantifying total and unbound lenalidomide concentrations in human plasma.</p><p><strong>Methods: </strong>Unbound concentrations were measured using plasma ultrafiltrate prepared with Amicon<sup>®</sup> Centrifugal Filters. Lenalidomide and lenalidomide-d5 (internal standard) were extracted from 50 μL of human plasma using liquid-liquid extraction. Chromatography was conducted with a Halo<sup>®</sup> C18 column using 0.1% formic acid and methanol (20:80, <i>v</i>/<i>v</i>) as the mobile phase. The mass spectrometer was operated in a positive ion mode with an electrospray ionization interface and multiple reaction monitoring modes.</p><p><strong>Results: </strong>Calibration curves were linear over the range of 5 to 1000 ng/mL (r<sup>2</sup> > 0.996) for both the total and unbound lenalidomide. For total lenalidomide concentrations, between-run precision (coefficients of variation) and accuracy were 1.70-7.65% and 94.45-101.10%, respectively. For unbound concentrations, inter-day precision and accuracy were 1.98-10.55% and 93.95-98.48%, respectively.</p><p><strong>Conclusions: </strong>We developed a highly reproducible, sensitive, and efficient bioanalytical method using a smaller volume of plasma sample (50 μL) with a relatively short run time (2.5 min). The proposed analytical method was successfully applied to measure total and unbound lenalidomide concentrations at various time points in multiple myeloma patients with renal impairment.</p>\",\"PeriodicalId\":19894,\"journal\":{\"name\":\"Pharmaceutics\",\"volume\":\"16 10\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511013/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/pharmaceutics16101340\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/pharmaceutics16101340","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:本研究旨在开发一种经过充分验证的 HPLC-MS/MS 方法,用于定量检测人体血浆中来那度胺的总浓度和未结合浓度:使用Amicon®离心过滤器制备的血浆超滤液测量非结合浓度。来那度胺和来那度胺-d5(内标)采用液液萃取法从50微升人体血浆中提取。色谱采用 Halo® C18 色谱柱,以 0.1% 甲酸和甲醇(20:80, v/v)为流动相。质谱仪采用电喷雾离子化界面的正离子模式和多重反应监测模式:来那度胺总浓度和未结合浓度在5至1000 ng/mL范围内线性关系良好(r2 > 0.996)。来那度胺总浓度的运行间精密度(变异系数)和准确度分别为1.70%-7.65%和94.45%-101.10%。未结合浓度的日间精密度和准确度分别为1.98-10.55%和93.95-98.48%:我们开发了一种重现性高、灵敏度高且高效的生物分析方法,使用的血浆样品量较小(50 μL),运行时间相对较短(2.5 分钟)。所提出的分析方法成功地用于测定肾功能受损的多发性骨髓瘤患者在不同时间点的来那度胺总浓度和未结合浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development and Validation of an Improved HPLC-MS/MS Method for Quantifying Total and Unbound Lenalidomide in Human Plasma.

Background/objectives: This study aimed to develop a fully validated HPLC-MS/MS method for quantifying total and unbound lenalidomide concentrations in human plasma.

Methods: Unbound concentrations were measured using plasma ultrafiltrate prepared with Amicon® Centrifugal Filters. Lenalidomide and lenalidomide-d5 (internal standard) were extracted from 50 μL of human plasma using liquid-liquid extraction. Chromatography was conducted with a Halo® C18 column using 0.1% formic acid and methanol (20:80, v/v) as the mobile phase. The mass spectrometer was operated in a positive ion mode with an electrospray ionization interface and multiple reaction monitoring modes.

Results: Calibration curves were linear over the range of 5 to 1000 ng/mL (r2 > 0.996) for both the total and unbound lenalidomide. For total lenalidomide concentrations, between-run precision (coefficients of variation) and accuracy were 1.70-7.65% and 94.45-101.10%, respectively. For unbound concentrations, inter-day precision and accuracy were 1.98-10.55% and 93.95-98.48%, respectively.

Conclusions: We developed a highly reproducible, sensitive, and efficient bioanalytical method using a smaller volume of plasma sample (50 μL) with a relatively short run time (2.5 min). The proposed analytical method was successfully applied to measure total and unbound lenalidomide concentrations at various time points in multiple myeloma patients with renal impairment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pharmaceutics
Pharmaceutics Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
7.90
自引率
11.10%
发文量
2379
审稿时长
16.41 days
期刊介绍: Pharmaceutics (ISSN 1999-4923) is an open access journal which provides an advanced forum for the science and technology of pharmaceutics and biopharmaceutics. It publishes reviews, regular research papers, communications,  and short notes. Covered topics include pharmacokinetics, toxicokinetics, pharmacodynamics, pharmacogenetics and pharmacogenomics, and pharmaceutical formulation. Our aim is to encourage scientists to publish their experimental and theoretical details in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
Modular Nanotransporters Deliver Anti-Keap1 Monobody into Mouse Hepatocytes, Thereby Inhibiting Production of Reactive Oxygen Species. Nanomaterial-Enhanced Microneedles: Emerging Therapies for Diabetes and Obesity. Effectiveness of Lyoprotectants in Protein Stabilization During Lyophilization. Recent Advances in the Drugs and Glucose-Responsive Drug Delivery Systems for the Treatment of Diabetes: A Systematic Review. A Novel Hydrogel Sponge for Three-Dimensional Cell Culture.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1