IF 4.7 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING American Journal of Roentgenology Pub Date : 2024-10-23 DOI:10.2214/AJR.24.31830
Xiaozhi Dang, Yi Gao, Yan Ju, Xiaojie Yuan, Huan Lin, Yi Ren, Yao Xiao, Rui Shu, Xiang Gu, Woo Kyung Moon, Hongping Song
{"title":"自动乳腺超声远程读片用于乳腺癌初筛:中国 46 家社区卫生中心参与的前瞻性研究。","authors":"Xiaozhi Dang, Yi Gao, Yan Ju, Xiaojie Yuan, Huan Lin, Yi Ren, Yao Xiao, Rui Shu, Xiang Gu, Woo Kyung Moon, Hongping Song","doi":"10.2214/AJR.24.31830","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> China has faced barriers to implementation of a population-based mammographic screening program. Breast ultrasound provides an alternative screening modality to mammography in low-resource settings. <b>Objective:</b> To evaluate the performance of ABUS with remote reading as the primary screening modality for breast cancer. <b>Methods:</b> This prospective study enrolled asymptomatic women 35-69 years old from 46 community health centers across 18 provinces representing all six regions of China from January 2021 to December 2021. Participants underwent screening ABUS as the sole breast cancer screening modality, with images acquired by a technologist at the community health center. The 3D volumetric data were transferred via cloud-based software to a single remote reading center, where examinations were interpreted independently in batches by two subspecialized breast radiologists using BI-RADS; a third radiologist at the remote reader center resolved discrepancies. Diagnostic reports were returned to the community centers, and patients sought follow-up care at local hospitals. The reference standard incorporated a combination of histopathology and 24-month follow-up. Outcomes measures included cancer detection rate, abnormal interpretation rate (AIR), sensitivity, specificity, biopsy rate, and PPV. <b>Results:</b> The final analysis included 5978 enrolled participants (median age, 46 years [IQR 40-52 years]) who underwent screening ABUS at the community health centers with subsequent remote reading. A total of 24 ABUS-detected cancers and two interval cancers were diagnosed. The cancer detection rate was 4.0 per 1000 women (95% CI: 2.7-5.9), and the AIR was 11.9% (95% CI: 11.1-12.7). A total of 95.8% (23/24) of ABUS-detected cancers were invasive. The 23 invasive cancers had a median diameter of 10.0 mm; 73.9% (17/23) were node-negative. Sensitivity was 92.3% (95% CI: 75.9-97.9), and specificity was 88.4% (95% CI: 87.6-89.2). The biopsy rate was 1.7% (95% CI: 1.4-2.0), and the PPV of biopsy was 24.0% (95% CI: 16.7-33.2). <b>Conclusion:</b> ABUS screening with remote reading met benchmark performance for cancer detection in comparison to mammography, with infrequent interval cancers. <b>Clinical Impact:</b> ABUS with remote reading holds promise in enhancing access to breast cancer screening and early detection in low-resource settings or underserved regions where mammographic screening is not established.</p>","PeriodicalId":55529,"journal":{"name":"American Journal of Roentgenology","volume":null,"pages":null},"PeriodicalIF":4.7000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automated Breast Ultrasound With Remote Reading for Primary Breast Cancer Screening: A Prospective Study Involving 46 Community Health Centers in China.\",\"authors\":\"Xiaozhi Dang, Yi Gao, Yan Ju, Xiaojie Yuan, Huan Lin, Yi Ren, Yao Xiao, Rui Shu, Xiang Gu, Woo Kyung Moon, Hongping Song\",\"doi\":\"10.2214/AJR.24.31830\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> China has faced barriers to implementation of a population-based mammographic screening program. Breast ultrasound provides an alternative screening modality to mammography in low-resource settings. <b>Objective:</b> To evaluate the performance of ABUS with remote reading as the primary screening modality for breast cancer. <b>Methods:</b> This prospective study enrolled asymptomatic women 35-69 years old from 46 community health centers across 18 provinces representing all six regions of China from January 2021 to December 2021. Participants underwent screening ABUS as the sole breast cancer screening modality, with images acquired by a technologist at the community health center. The 3D volumetric data were transferred via cloud-based software to a single remote reading center, where examinations were interpreted independently in batches by two subspecialized breast radiologists using BI-RADS; a third radiologist at the remote reader center resolved discrepancies. Diagnostic reports were returned to the community centers, and patients sought follow-up care at local hospitals. The reference standard incorporated a combination of histopathology and 24-month follow-up. Outcomes measures included cancer detection rate, abnormal interpretation rate (AIR), sensitivity, specificity, biopsy rate, and PPV. <b>Results:</b> The final analysis included 5978 enrolled participants (median age, 46 years [IQR 40-52 years]) who underwent screening ABUS at the community health centers with subsequent remote reading. A total of 24 ABUS-detected cancers and two interval cancers were diagnosed. The cancer detection rate was 4.0 per 1000 women (95% CI: 2.7-5.9), and the AIR was 11.9% (95% CI: 11.1-12.7). A total of 95.8% (23/24) of ABUS-detected cancers were invasive. The 23 invasive cancers had a median diameter of 10.0 mm; 73.9% (17/23) were node-negative. Sensitivity was 92.3% (95% CI: 75.9-97.9), and specificity was 88.4% (95% CI: 87.6-89.2). The biopsy rate was 1.7% (95% CI: 1.4-2.0), and the PPV of biopsy was 24.0% (95% CI: 16.7-33.2). <b>Conclusion:</b> ABUS screening with remote reading met benchmark performance for cancer detection in comparison to mammography, with infrequent interval cancers. <b>Clinical Impact:</b> ABUS with remote reading holds promise in enhancing access to breast cancer screening and early detection in low-resource settings or underserved regions where mammographic screening is not established.</p>\",\"PeriodicalId\":55529,\"journal\":{\"name\":\"American Journal of Roentgenology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Roentgenology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2214/AJR.24.31830\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Roentgenology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2214/AJR.24.31830","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:中国在实施以人口为基础的乳腺 X 线照相筛查计划时遇到了障碍。在资源匮乏的环境中,乳腺超声可作为乳腺 X 线照相术的替代筛查方法。目的评估采用远程读片的 ABUS 作为乳腺癌主要筛查方式的性能。方法:这项前瞻性研究在 2021 年 1 月至 2021 年 12 月期间,从代表中国所有六个地区的 18 个省的 46 个社区卫生中心招募了 35-69 岁的无症状女性。参与者接受 ABUS 作为唯一的乳腺癌筛查方式,由社区卫生中心的技术人员采集图像。三维容积数据通过云端软件传输到单个远程阅片中心,由两名乳腺放射亚专业医师使用 BI-RADS 分批独立解读检查结果;远程阅片中心的第三名放射医师负责解决差异问题。诊断报告返回社区中心,患者在当地医院接受后续治疗。参考标准包括组织病理学和 24 个月的随访。结果衡量指标包括癌症检出率、异常判读率(AIR)、灵敏度、特异性、活检率和 PPV。结果:最终分析包括 5978 名在社区卫生中心接受 ABUS 筛查并随后接受远程读片的参与者(中位年龄 46 岁 [IQR 40-52 岁])。共诊断出 24 例 ABUS 检测出的癌症和 2 例间期癌症。癌症检出率为每 1000 名妇女中 4.0 例(95% CI:2.7-5.9),AIR 为 11.9%(95% CI:11.1-12.7)。在 ABUS 检测出的癌症中,共有 95.8%(23/24)为浸润性。这 23 例浸润性癌症的中位直径为 10.0 毫米;73.9%(17/23)为结节阴性。灵敏度为 92.3%(95% CI:75.9-97.9),特异性为 88.4%(95% CI:87.6-89.2)。活检率为 1.7% (95% CI: 1.4-2.0),活检的 PPV 为 24.0% (95% CI: 16.7-33.2)。结论与乳腺放射摄影相比,采用远程读片的 ABUS 筛查在癌症检测方面达到了基准性能,但间歇性癌症的发生率较低。临床影响:在乳腺放射摄影筛查尚未建立的低资源环境或服务不足地区,采用远程读片的 ABUS 有望提高乳腺癌筛查和早期检测的可及性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automated Breast Ultrasound With Remote Reading for Primary Breast Cancer Screening: A Prospective Study Involving 46 Community Health Centers in China.

Background: China has faced barriers to implementation of a population-based mammographic screening program. Breast ultrasound provides an alternative screening modality to mammography in low-resource settings. Objective: To evaluate the performance of ABUS with remote reading as the primary screening modality for breast cancer. Methods: This prospective study enrolled asymptomatic women 35-69 years old from 46 community health centers across 18 provinces representing all six regions of China from January 2021 to December 2021. Participants underwent screening ABUS as the sole breast cancer screening modality, with images acquired by a technologist at the community health center. The 3D volumetric data were transferred via cloud-based software to a single remote reading center, where examinations were interpreted independently in batches by two subspecialized breast radiologists using BI-RADS; a third radiologist at the remote reader center resolved discrepancies. Diagnostic reports were returned to the community centers, and patients sought follow-up care at local hospitals. The reference standard incorporated a combination of histopathology and 24-month follow-up. Outcomes measures included cancer detection rate, abnormal interpretation rate (AIR), sensitivity, specificity, biopsy rate, and PPV. Results: The final analysis included 5978 enrolled participants (median age, 46 years [IQR 40-52 years]) who underwent screening ABUS at the community health centers with subsequent remote reading. A total of 24 ABUS-detected cancers and two interval cancers were diagnosed. The cancer detection rate was 4.0 per 1000 women (95% CI: 2.7-5.9), and the AIR was 11.9% (95% CI: 11.1-12.7). A total of 95.8% (23/24) of ABUS-detected cancers were invasive. The 23 invasive cancers had a median diameter of 10.0 mm; 73.9% (17/23) were node-negative. Sensitivity was 92.3% (95% CI: 75.9-97.9), and specificity was 88.4% (95% CI: 87.6-89.2). The biopsy rate was 1.7% (95% CI: 1.4-2.0), and the PPV of biopsy was 24.0% (95% CI: 16.7-33.2). Conclusion: ABUS screening with remote reading met benchmark performance for cancer detection in comparison to mammography, with infrequent interval cancers. Clinical Impact: ABUS with remote reading holds promise in enhancing access to breast cancer screening and early detection in low-resource settings or underserved regions where mammographic screening is not established.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
12.80
自引率
4.00%
发文量
920
审稿时长
3 months
期刊介绍: Founded in 1907, the monthly American Journal of Roentgenology (AJR) is the world’s longest continuously published general radiology journal. AJR is recognized as among the specialty’s leading peer-reviewed journals and has a worldwide circulation of close to 25,000. The journal publishes clinically-oriented articles across all radiology subspecialties, seeking relevance to radiologists’ daily practice. The journal publishes hundreds of articles annually with a diverse range of formats, including original research, reviews, clinical perspectives, editorials, and other short reports. The journal engages its audience through a spectrum of social media and digital communication activities.
期刊最新文献
Advanced Imaging of the Peripheral Nerves, From the AJR "How We Do It" Special Series. CT Surveillance for Local Recurrence After Pancreatic Cancer Resection: Evaluation of Imaging Findings From the SAR Disease-Focused Panel Consensus Statement. Importance of Education in Radiation Safety During Medical School: A Medical Student's Perspective. PPV of Bone Uptake of 18F-Flotufolastat: Evaluation Using SPOTLIGHT Study Data. MR and Ultrasound Elastography for Fibrosis Assessment in Children: Practical Implementation and Supporting Evidence-AJR Expert Panel Narrative Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1