Clareon 与 AcrySof PanOptix 三焦点人工晶体:患者满意度和视觉效果比较研究。

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2024-10-18 eCollection Date: 2024-01-01 DOI:10.2147/OPTH.S476666
John A Hovanesian, Michael Jones, Quentin Allen
{"title":"Clareon 与 AcrySof PanOptix 三焦点人工晶体:患者满意度和视觉效果比较研究。","authors":"John A Hovanesian, Michael Jones, Quentin Allen","doi":"10.2147/OPTH.S476666","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate patient-reported outcomes of cataract surgery using the Clareon Panoptix and Panoptix Toric trifocal lenses and to compare these to the data collected previously for the AcrySof Panoptix and Panoptix Toric.</p><p><strong>Patients and methods: </strong>Prospective, open-label, multicenter analysis of satisfaction, spectacle independence, presence of unwanted side effects, and best-corrected visual acuity among patients undergoing cataract surgery who had been implanted at least 1 month previously with the Clareon PanOptix or PanOptix Toric trifocal IOL bilaterally. Results were compared to outcomes measured two years ago from a similar study with the AcrySof version of the same lens.</p><p><strong>Results: </strong>No significant differences in patient satisfaction rates were reported between the two cohorts. Spectacle independence was similar with 88% of Clareon Panoptix and 83% of AcrySof Panoptix patients having no need for any corrective lenses. Quality of vision was not statistically different with 7% of Clareon vs 15% of AcrySof patients reporting \"very much\" or more of glare/halo severity. Significantly more AcrySof (66%) than Clareon (42%) patients achieved a spherical equivalent outcome within 0.25 D of target. Best corrected distance visual acuity differences were not statistically significant, and no safety concerns were reported.</p><p><strong>Conclusion: </strong>The Clareon PanOptix trifocal lens provides similar satisfaction and spectacle independence and has a similar side effect profile and BCVA outcome to the identical lens made of the predecessor AcrySof lens.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11495208/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Clareon Vs AcrySof PanOptix Trifocal IOL: A Comparative Study of Patient Satisfaction and Visual Performance.\",\"authors\":\"John A Hovanesian, Michael Jones, Quentin Allen\",\"doi\":\"10.2147/OPTH.S476666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate patient-reported outcomes of cataract surgery using the Clareon Panoptix and Panoptix Toric trifocal lenses and to compare these to the data collected previously for the AcrySof Panoptix and Panoptix Toric.</p><p><strong>Patients and methods: </strong>Prospective, open-label, multicenter analysis of satisfaction, spectacle independence, presence of unwanted side effects, and best-corrected visual acuity among patients undergoing cataract surgery who had been implanted at least 1 month previously with the Clareon PanOptix or PanOptix Toric trifocal IOL bilaterally. Results were compared to outcomes measured two years ago from a similar study with the AcrySof version of the same lens.</p><p><strong>Results: </strong>No significant differences in patient satisfaction rates were reported between the two cohorts. Spectacle independence was similar with 88% of Clareon Panoptix and 83% of AcrySof Panoptix patients having no need for any corrective lenses. Quality of vision was not statistically different with 7% of Clareon vs 15% of AcrySof patients reporting \\\"very much\\\" or more of glare/halo severity. Significantly more AcrySof (66%) than Clareon (42%) patients achieved a spherical equivalent outcome within 0.25 D of target. Best corrected distance visual acuity differences were not statistically significant, and no safety concerns were reported.</p><p><strong>Conclusion: </strong>The Clareon PanOptix trifocal lens provides similar satisfaction and spectacle independence and has a similar side effect profile and BCVA outcome to the identical lens made of the predecessor AcrySof lens.</p>\",\"PeriodicalId\":93945,\"journal\":{\"name\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11495208/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTH.S476666\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S476666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估使用 Clareon Panoptix 和 Panoptix Toric 三焦点镜片进行白内障手术的患者报告结果,并将这些结果与之前收集的 AcrySof Panoptix 和 Panoptix Toric 的数据进行比较:前瞻性、开放标签、多中心分析,对至少 1 个月前接受过双侧植入 Clareon PanOptix 或 PanOptix Toric 三焦点人工晶体的白内障手术患者的满意度、眼镜独立性、是否存在不必要的副作用以及最佳矫正视力进行分析。研究结果与两年前一项类似研究中使用同一镜片的 AcrySof 版本得出的结果进行了比较:结果:两组患者的满意度无明显差异。88% 的 Clareon Panoptix 患者和 83% 的 AcrySof Panoptix 患者都不需要任何矫正镜片。视力质量没有统计学差异,7% 的 Clareon 患者和 15% 的 AcrySof 患者报告眩光/光晕严重程度为 "非常严重 "或更严重。达到球面等效 0.25 D 目标值的 AcrySof 患者(66%)明显多于 Clareon 患者(42%)。最佳矫正距离视力差异无统计学意义,也未报告任何安全问题:结论:Clareon PanOptix 三焦点镜片与前代 AcrySof 镜片相比,具有相似的满意度和眼镜独立性,副作用和 BCVA 结果也相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Clareon Vs AcrySof PanOptix Trifocal IOL: A Comparative Study of Patient Satisfaction and Visual Performance.

Purpose: To evaluate patient-reported outcomes of cataract surgery using the Clareon Panoptix and Panoptix Toric trifocal lenses and to compare these to the data collected previously for the AcrySof Panoptix and Panoptix Toric.

Patients and methods: Prospective, open-label, multicenter analysis of satisfaction, spectacle independence, presence of unwanted side effects, and best-corrected visual acuity among patients undergoing cataract surgery who had been implanted at least 1 month previously with the Clareon PanOptix or PanOptix Toric trifocal IOL bilaterally. Results were compared to outcomes measured two years ago from a similar study with the AcrySof version of the same lens.

Results: No significant differences in patient satisfaction rates were reported between the two cohorts. Spectacle independence was similar with 88% of Clareon Panoptix and 83% of AcrySof Panoptix patients having no need for any corrective lenses. Quality of vision was not statistically different with 7% of Clareon vs 15% of AcrySof patients reporting "very much" or more of glare/halo severity. Significantly more AcrySof (66%) than Clareon (42%) patients achieved a spherical equivalent outcome within 0.25 D of target. Best corrected distance visual acuity differences were not statistically significant, and no safety concerns were reported.

Conclusion: The Clareon PanOptix trifocal lens provides similar satisfaction and spectacle independence and has a similar side effect profile and BCVA outcome to the identical lens made of the predecessor AcrySof lens.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
期刊最新文献
Association Between Particulate Matter Pollutants and Ophthalmology Visits for Ocular Surface Irritation and Allergy. The Cutting Efficiency of a Hybrid Phacoemulsification Tip Using High and Low Intraocular Pressure Settings in Different Grades of Cataract. Comparison of Large Language Models in Diagnosis and Management of Challenging Clinical Cases. Enhancing OCT Reliability: The Role of Eye-Tracking in Achieving Consistent Retinal Measurements [Letter]. Baseline Characteristics and Clinical Outcomes of Patients Seen Through the Free Diabetes Screening (FDS) Program.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1