Ashlee Jade Medica, Zamira Gibb, Robert John Aitken
{"title":"优化马精子质量:单层离心法精子分离的替代方法。","authors":"Ashlee Jade Medica, Zamira Gibb, Robert John Aitken","doi":"10.1530/RAF-23-0081","DOIUrl":null,"url":null,"abstract":"<p><strong>Graphical abstract: </strong></p><p><strong>Abstract: </strong>In vitro semen purification techniques have been developed that seek to mimic the in vivo selection process in order to generate the highest possible chance of oocyte fertilization following artificial insemination. Numerous methods have been developed to isolate functional spermatozoa for artificial insemination, yet only one method, single-layer centrifugation using commercial preparations like EquiPure, has been widely employed. In this study, we have introduced a novel approach for isolating spermatozoa and compared their quality to those isolated using EquiPure. The AI port system (Memphasys, Ltd. in Sydney, Australia) features a disposable cartridge with an inoculation chamber for depositing extended semen and a harvest chamber for extracting isolated spermatozoa. These chambers are separated by a 5 µm polyethylene terephthalate (PETE) membrane, allowing highly motile spermatozoa to migrate from the inoculation chamber to the harvest chamber over a 20-minute period. This migration effectively leaves behind seminal plasma and other cell types, such as leukocytes. Comparative analyses between spermatozoa isolated with the AI port and EquiPure demonstrated that, across all measured sperm parameters, including yield, vitality, motility, morphology, DNA fragmentation, and mitochondrial superoxide generation, the AI port-isolated cells exhibited comparable or superior performance, particularly in terms of DNA fragmentation. In summary, the AI port system demonstrates the potential to efficiently isolate high-quality spermatozoa, possibly offering a cost-effective and user-friendly alternative that may enhance the success rates of artificial insemination in breeding programs.</p><p><strong>Lay summary: </strong>This study aimed to create a new method for refining stallion semen to increase the likelihood of a successful pregnancy through artificial insemination. While there are existing techniques for isolating high-quality sperm, the most common involves a complicated process using a centrifuge, which spins the semen to separate it. This research introduces a new approach called the AI port system that uses a disposable cartridge with two separate chambers for putting in semen and getting out isolated sperm. A membrane between the chambers acts like a filter, letting highly motile sperm swim across, leaving behind unwanted substances like bacteria and blood cells. Compared to the centrifugation method, the AI port system effectively produces sperm with comparable or better quality in various aspects, including vitality, movement, shape, DNA integrity, and energy production. In summary, the AI port system is an easy-to-use alternative with the potential to improve the success of artificial insemination in horse breeding programs.</p>","PeriodicalId":101312,"journal":{"name":"Reproduction & fertility","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11558927/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing equine sperm quality: an alternative to single layer centrifugation for sperm isolation.\",\"authors\":\"Ashlee Jade Medica, Zamira Gibb, Robert John Aitken\",\"doi\":\"10.1530/RAF-23-0081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Graphical abstract: </strong></p><p><strong>Abstract: </strong>In vitro semen purification techniques have been developed that seek to mimic the in vivo selection process in order to generate the highest possible chance of oocyte fertilization following artificial insemination. Numerous methods have been developed to isolate functional spermatozoa for artificial insemination, yet only one method, single-layer centrifugation using commercial preparations like EquiPure, has been widely employed. In this study, we have introduced a novel approach for isolating spermatozoa and compared their quality to those isolated using EquiPure. The AI port system (Memphasys, Ltd. in Sydney, Australia) features a disposable cartridge with an inoculation chamber for depositing extended semen and a harvest chamber for extracting isolated spermatozoa. These chambers are separated by a 5 µm polyethylene terephthalate (PETE) membrane, allowing highly motile spermatozoa to migrate from the inoculation chamber to the harvest chamber over a 20-minute period. This migration effectively leaves behind seminal plasma and other cell types, such as leukocytes. Comparative analyses between spermatozoa isolated with the AI port and EquiPure demonstrated that, across all measured sperm parameters, including yield, vitality, motility, morphology, DNA fragmentation, and mitochondrial superoxide generation, the AI port-isolated cells exhibited comparable or superior performance, particularly in terms of DNA fragmentation. In summary, the AI port system demonstrates the potential to efficiently isolate high-quality spermatozoa, possibly offering a cost-effective and user-friendly alternative that may enhance the success rates of artificial insemination in breeding programs.</p><p><strong>Lay summary: </strong>This study aimed to create a new method for refining stallion semen to increase the likelihood of a successful pregnancy through artificial insemination. While there are existing techniques for isolating high-quality sperm, the most common involves a complicated process using a centrifuge, which spins the semen to separate it. This research introduces a new approach called the AI port system that uses a disposable cartridge with two separate chambers for putting in semen and getting out isolated sperm. A membrane between the chambers acts like a filter, letting highly motile sperm swim across, leaving behind unwanted substances like bacteria and blood cells. Compared to the centrifugation method, the AI port system effectively produces sperm with comparable or better quality in various aspects, including vitality, movement, shape, DNA integrity, and energy production. In summary, the AI port system is an easy-to-use alternative with the potential to improve the success of artificial insemination in horse breeding programs.</p>\",\"PeriodicalId\":101312,\"journal\":{\"name\":\"Reproduction & fertility\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11558927/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reproduction & fertility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1530/RAF-23-0081\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q2\",\"JCRName\":\"REPRODUCTIVE BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reproduction & fertility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1530/RAF-23-0081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Print","JCR":"Q2","JCRName":"REPRODUCTIVE BIOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
体外精液纯化技术的开发旨在模仿体内精子筛选过程,以便在人工授精后尽可能提高卵母细胞受精的几率。目前已开发出许多方法来分离用于人工授精的功能性精子,但只有一种方法被广泛采用,即使用 EquiPure 等商业制剂进行单层离心。在这项研究中,我们引入了一种分离精子的新方法,并将其质量与使用 EquiPure 分离的精子进行了比较。AI 端口系统(澳大利亚悉尼的 Memphasys 有限公司)配有一个一次性盒,其中的接种室用于存放扩展精液,收获室用于提取分离精子。这些腔室由 5 微米 PETE 膜隔开,使高度运动的精子在 20 分钟内从接种腔室迁移到收获腔室。这种迁移有效地留下了精浆和其他类型的细胞,如白细胞。对使用 AI 端口和 EquiPure 分离的精子进行的比较分析表明,在所有测量的精子参数(包括产量、活力、运动性、形态、DNA 断裂和线粒体超氧化物生成)中,AI 端口分离的细胞表现出相当或更优的性能,尤其是在 DNA 断裂方面。总之,AI-Port 系统展示了高效分离优质精子的潜力,有可能提供一种成本效益高且用户友好的替代方案,从而提高育种项目中人工授精的成功率。
Optimizing equine sperm quality: an alternative to single layer centrifugation for sperm isolation.
Graphical abstract:
Abstract: In vitro semen purification techniques have been developed that seek to mimic the in vivo selection process in order to generate the highest possible chance of oocyte fertilization following artificial insemination. Numerous methods have been developed to isolate functional spermatozoa for artificial insemination, yet only one method, single-layer centrifugation using commercial preparations like EquiPure, has been widely employed. In this study, we have introduced a novel approach for isolating spermatozoa and compared their quality to those isolated using EquiPure. The AI port system (Memphasys, Ltd. in Sydney, Australia) features a disposable cartridge with an inoculation chamber for depositing extended semen and a harvest chamber for extracting isolated spermatozoa. These chambers are separated by a 5 µm polyethylene terephthalate (PETE) membrane, allowing highly motile spermatozoa to migrate from the inoculation chamber to the harvest chamber over a 20-minute period. This migration effectively leaves behind seminal plasma and other cell types, such as leukocytes. Comparative analyses between spermatozoa isolated with the AI port and EquiPure demonstrated that, across all measured sperm parameters, including yield, vitality, motility, morphology, DNA fragmentation, and mitochondrial superoxide generation, the AI port-isolated cells exhibited comparable or superior performance, particularly in terms of DNA fragmentation. In summary, the AI port system demonstrates the potential to efficiently isolate high-quality spermatozoa, possibly offering a cost-effective and user-friendly alternative that may enhance the success rates of artificial insemination in breeding programs.
Lay summary: This study aimed to create a new method for refining stallion semen to increase the likelihood of a successful pregnancy through artificial insemination. While there are existing techniques for isolating high-quality sperm, the most common involves a complicated process using a centrifuge, which spins the semen to separate it. This research introduces a new approach called the AI port system that uses a disposable cartridge with two separate chambers for putting in semen and getting out isolated sperm. A membrane between the chambers acts like a filter, letting highly motile sperm swim across, leaving behind unwanted substances like bacteria and blood cells. Compared to the centrifugation method, the AI port system effectively produces sperm with comparable or better quality in various aspects, including vitality, movement, shape, DNA integrity, and energy production. In summary, the AI port system is an easy-to-use alternative with the potential to improve the success of artificial insemination in horse breeding programs.