ProDesign Logic 文件对根尖孔磨损和椎间孔扩大后形状变化的影响。

IF 2.5 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Dentistry Journal Pub Date : 2024-10-16 DOI:10.3390/dj12100330
Miguel Christian Castillo Marin, Amjad Abu Hasna, Marcos Frozoni, Mariana Gadelho Gimenez Diamantino, Caroline Trefiglio Rocha, Marcia Carneiro Valera, Cláudio Antonio Talge Carvalho
{"title":"ProDesign Logic 文件对根尖孔磨损和椎间孔扩大后形状变化的影响。","authors":"Miguel Christian Castillo Marin, Amjad Abu Hasna, Marcos Frozoni, Mariana Gadelho Gimenez Diamantino, Caroline Trefiglio Rocha, Marcia Carneiro Valera, Cláudio Antonio Talge Carvalho","doi":"10.3390/dj12100330","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond.</p><p><strong>Methods: </strong>Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (<i>n</i> = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student's <i>t</i>-test, Kruskal-Wallis, and Mann-Whitney test.</p><p><strong>Results: </strong>Significant differences (<i>p</i> < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina.</p><p><strong>Conclusion: </strong>ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"12 10","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506177/pdf/","citationCount":"0","resultStr":"{\"title\":\"ProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement.\",\"authors\":\"Miguel Christian Castillo Marin, Amjad Abu Hasna, Marcos Frozoni, Mariana Gadelho Gimenez Diamantino, Caroline Trefiglio Rocha, Marcia Carneiro Valera, Cláudio Antonio Talge Carvalho\",\"doi\":\"10.3390/dj12100330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/objectives: </strong>This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond.</p><p><strong>Methods: </strong>Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (<i>n</i> = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student's <i>t</i>-test, Kruskal-Wallis, and Mann-Whitney test.</p><p><strong>Results: </strong>Significant differences (<i>p</i> < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina.</p><p><strong>Conclusion: </strong>ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":\"12 10\",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506177/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj12100330\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12100330","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:本研究旨在评估 ProDesign Logic 文件 45.01 和 50.01 在牙长(TL)和 1 mm 以外的穹窿扩大后对根尖孔磨损和形状改变的影响:将 60 颗刚拔出的单根下前臼齿随机分为 5 组(n = 12):第 1 组(40.05 WL)(对照组):第 2 组(45.01 TL):在 TL 处使用 45.01 Prodesign Logic 文件对标本进行髓腔扩大;第 3 组(45.01 TL + 1):第 4 组(50.01 TL):在 TL 处使用 50.01 Prodesign Logic 文件进行椎管扩大;第 5 组(50.01 TL + 1):用 50.01 Prodesign Logic 文件在 TL 外 1 mm 处进行椎管扩大。扫描电子显微镜用于评估根尖孔的变化和形状改变。数据分析采用学生 t 检验、Kruskal-Wallis 检验和 Mann-Whitney 检验:结果:与对照组相比,所有受试组的根尖孔平均磨损面积均有显著差异(P < 0.01)。心尖孔扩大导致心尖孔形状发生显著变化,形成圆形心尖孔:结论:在TL处使用ProDesign Logic 45.01和50.01锉会导致明显的磨损和圆孔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement.

Background/objectives: This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond.

Methods: Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (n = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student's t-test, Kruskal-Wallis, and Mann-Whitney test.

Results: Significant differences (p < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina.

Conclusion: ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
期刊最新文献
Home Biofilm Management in Orthodontic Aligners: A Systematic Review. In Vitro Research Methods Used to Evaluate Shaping Ability of Rotary Endodontic Files-A Literature Review. Accuracy and Efficiency of the Surgical-Guide-Assisted Fiber Post Removal Technique for Anterior Teeth: An Ex Vivo Study. Correlation between Periodontitis and Onset of Alzheimer's Disease: A Literature Review. The Harmful Effects of Welding Fumes on Human Dental Enamel-A Microhardness Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1