P Gebhardt, B Lavin, A Phinikaridou, J MacKewn, M Henningsson, D Schug, A Salomon, P K Marsden, V Schulz, R M Botnar
{"title":"应用于新西兰白兔动脉粥样硬化斑块成像的同步 PET-MRI Hyperion IIDPET 插件的初步结果。","authors":"P Gebhardt, B Lavin, A Phinikaridou, J MacKewn, M Henningsson, D Schug, A Salomon, P K Marsden, V Schulz, R M Botnar","doi":"10.1088/1361-6560/ad8c1f","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>In preclinical research,<i>in vivo</i>imaging of mice and rats is more common than any other animal species, since their physiopathology is very well-known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini-pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required. In case of hybrid imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI), clinical systems have to be used, as these animal models do not typically fit in preclinical simultaneous PET-MRI scanners.<i>Approach.</i>In this paper, we present initial imaging results obtained with the Hyperion II<sup>D</sup>PET insert which can accommodate NZW rabbits when combined with a large volume MRI RF coil. First, we developed a rabbit-sized image quality phantom of comparable size to a NZW rabbit in order to evaluate the PET imaging performance of the insert under high count rates. For this phantom, radioactive spheres with inner diameters between 3.95 and7.86mm were visible in a warm background with a tracer activity ratio of 4.1 to 1 and with a total<sup>18</sup>F activity in the phantom of58MBq at measurement start. Second, we performed simultaneous PET-MR imaging of atherosclerotic plaques in a rabbit<i>in vivo</i>using a single injection containing<sup>18</sup>F-FDG for detection of inflammatory activity, and Gd-ESMA for visualization of the aortic vessel wall and plaques with MRI.<i>Main results.</i>The fused PET-MR images reveal<sup>18</sup>F-FDG uptake within an active plaques with plaque thicknesses in the sub-millimeter range. Histology showed colocalization of<sup>18</sup>F-FDG uptake with macrophages in the aortic vessel wall lesions.<i>Significance.</i>Our initial results demonstrate that this PET insert is a promising system for simultaneous high-resolution PET-MR atherosclerotic plaque imaging studies in NZW rabbits.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Initial results of the Hyperion II<sup><i>D</i></sup>PET insert for simultaneous PET-MRI applied to atherosclerotic plaque imaging in New-Zealand white rabbits.\",\"authors\":\"P Gebhardt, B Lavin, A Phinikaridou, J MacKewn, M Henningsson, D Schug, A Salomon, P K Marsden, V Schulz, R M Botnar\",\"doi\":\"10.1088/1361-6560/ad8c1f\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>In preclinical research,<i>in vivo</i>imaging of mice and rats is more common than any other animal species, since their physiopathology is very well-known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini-pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required. In case of hybrid imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI), clinical systems have to be used, as these animal models do not typically fit in preclinical simultaneous PET-MRI scanners.<i>Approach.</i>In this paper, we present initial imaging results obtained with the Hyperion II<sup>D</sup>PET insert which can accommodate NZW rabbits when combined with a large volume MRI RF coil. First, we developed a rabbit-sized image quality phantom of comparable size to a NZW rabbit in order to evaluate the PET imaging performance of the insert under high count rates. For this phantom, radioactive spheres with inner diameters between 3.95 and7.86mm were visible in a warm background with a tracer activity ratio of 4.1 to 1 and with a total<sup>18</sup>F activity in the phantom of58MBq at measurement start. Second, we performed simultaneous PET-MR imaging of atherosclerotic plaques in a rabbit<i>in vivo</i>using a single injection containing<sup>18</sup>F-FDG for detection of inflammatory activity, and Gd-ESMA for visualization of the aortic vessel wall and plaques with MRI.<i>Main results.</i>The fused PET-MR images reveal<sup>18</sup>F-FDG uptake within an active plaques with plaque thicknesses in the sub-millimeter range. Histology showed colocalization of<sup>18</sup>F-FDG uptake with macrophages in the aortic vessel wall lesions.<i>Significance.</i>Our initial results demonstrate that this PET insert is a promising system for simultaneous high-resolution PET-MR atherosclerotic plaque imaging studies in NZW rabbits.</p>\",\"PeriodicalId\":20185,\"journal\":{\"name\":\"Physics in medicine and biology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-02-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics in medicine and biology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6560/ad8c1f\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad8c1f","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Initial results of the Hyperion IIDPET insert for simultaneous PET-MRI applied to atherosclerotic plaque imaging in New-Zealand white rabbits.
Objective.In preclinical research,in vivoimaging of mice and rats is more common than any other animal species, since their physiopathology is very well-known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini-pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required. In case of hybrid imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI), clinical systems have to be used, as these animal models do not typically fit in preclinical simultaneous PET-MRI scanners.Approach.In this paper, we present initial imaging results obtained with the Hyperion IIDPET insert which can accommodate NZW rabbits when combined with a large volume MRI RF coil. First, we developed a rabbit-sized image quality phantom of comparable size to a NZW rabbit in order to evaluate the PET imaging performance of the insert under high count rates. For this phantom, radioactive spheres with inner diameters between 3.95 and7.86mm were visible in a warm background with a tracer activity ratio of 4.1 to 1 and with a total18F activity in the phantom of58MBq at measurement start. Second, we performed simultaneous PET-MR imaging of atherosclerotic plaques in a rabbitin vivousing a single injection containing18F-FDG for detection of inflammatory activity, and Gd-ESMA for visualization of the aortic vessel wall and plaques with MRI.Main results.The fused PET-MR images reveal18F-FDG uptake within an active plaques with plaque thicknesses in the sub-millimeter range. Histology showed colocalization of18F-FDG uptake with macrophages in the aortic vessel wall lesions.Significance.Our initial results demonstrate that this PET insert is a promising system for simultaneous high-resolution PET-MR atherosclerotic plaque imaging studies in NZW rabbits.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry