用超声波检查评估半月板挤压:系统回顾和荟萃分析。

Khalis Boksh, Duncan E T Shepherd, Daniel M Espino, Jenna Shepherd, Arijit Ghosh, Randeep Aujla, Tarek Boutefnouchet
{"title":"用超声波检查评估半月板挤压:系统回顾和荟萃分析。","authors":"Khalis Boksh, Duncan E T Shepherd, Daniel M Espino, Jenna Shepherd, Arijit Ghosh, Randeep Aujla, Tarek Boutefnouchet","doi":"10.1186/s43019-024-00236-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Magnetic resonance imaging (MRI) is the imaging of choice for meniscal extrusion (ME). However, they may underappreciate the load-dependent changes of the meniscus. There is growing evidence that weight-bearing ultrasound (WB US) is more suitable, particularly in revealing occult extrusion. We therefore perform a systematic review and meta-analysis on the validity and reliability of US in diagnosing extrusion. Furthermore, we explored whether it detects differences in extrusion between loaded and unloaded positions and those with pathological (osteoarthritis and meniscal injury) and healthy knees.</p><p><strong>Methods: </strong>The Cochrane Controlled Register of Trials, PubMed, Medline, and Embase were used to perform a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. Data pertaining to intra- and interrater reliability of US in measuring meniscal extrusion (ME), its correlation with magnetic resonance imaging (MRI), and head-to-head comparison of potential factors to influence ME were included [loading versus unloading position; osteoarthritis (OA) or pathological menisci (PM) versus healthy knees; mild versus moderate-severe knee OA]. Pooled data were analyzed by random or fixed-effects models.</p><p><strong>Results: </strong>A total of 31 studies were included. Intraclass correlation coefficients (ICC) for intra- and interrater reliability were minimum 0.94 and 0.91, respectively. The correlation between US and MRI was (r = 0.76). US detected ME to be greater in the loaded position in all knees (healthy, p < 0.00001; OA, p < 0.00001; PM, p = 0.02). In all positions, US detected greater extrusion in OA (p < 0.0003) and PM knees (p = 0.006) compared with healthy controls. Furthermore, US revealed greater extrusion in moderate-severe OA knees (p < 0.00001).</p><p><strong>Conclusions: </strong>This systematic review suggests ultrasonography can play an important role in the measurement of meniscal extrusion, with results comparable to that of MRI. However, to what extent it can differentiate between physiological and pathological extrusion requires further investigation, with an absolute cutoff value yet to be determined. Nevertheless, it is an appropriate investigation to track the progression of disease in those with meniscal pathologies or osteoarthritis. Furthermore, it is a feasible investigation to evaluate the meniscal function following surgery.</p><p><strong>Level of evidence: </strong>IV, Systematic review of level III-IV evidence.</p>","PeriodicalId":36317,"journal":{"name":"Knee Surgery and Related Research","volume":"36 1","pages":"33"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11514433/pdf/","citationCount":"0","resultStr":"{\"title\":\"Assessment of meniscal extrusion with ultrasonography: a systematic review and meta-analysis.\",\"authors\":\"Khalis Boksh, Duncan E T Shepherd, Daniel M Espino, Jenna Shepherd, Arijit Ghosh, Randeep Aujla, Tarek Boutefnouchet\",\"doi\":\"10.1186/s43019-024-00236-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Magnetic resonance imaging (MRI) is the imaging of choice for meniscal extrusion (ME). However, they may underappreciate the load-dependent changes of the meniscus. There is growing evidence that weight-bearing ultrasound (WB US) is more suitable, particularly in revealing occult extrusion. We therefore perform a systematic review and meta-analysis on the validity and reliability of US in diagnosing extrusion. Furthermore, we explored whether it detects differences in extrusion between loaded and unloaded positions and those with pathological (osteoarthritis and meniscal injury) and healthy knees.</p><p><strong>Methods: </strong>The Cochrane Controlled Register of Trials, PubMed, Medline, and Embase were used to perform a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. Data pertaining to intra- and interrater reliability of US in measuring meniscal extrusion (ME), its correlation with magnetic resonance imaging (MRI), and head-to-head comparison of potential factors to influence ME were included [loading versus unloading position; osteoarthritis (OA) or pathological menisci (PM) versus healthy knees; mild versus moderate-severe knee OA]. Pooled data were analyzed by random or fixed-effects models.</p><p><strong>Results: </strong>A total of 31 studies were included. Intraclass correlation coefficients (ICC) for intra- and interrater reliability were minimum 0.94 and 0.91, respectively. The correlation between US and MRI was (r = 0.76). US detected ME to be greater in the loaded position in all knees (healthy, p < 0.00001; OA, p < 0.00001; PM, p = 0.02). In all positions, US detected greater extrusion in OA (p < 0.0003) and PM knees (p = 0.006) compared with healthy controls. Furthermore, US revealed greater extrusion in moderate-severe OA knees (p < 0.00001).</p><p><strong>Conclusions: </strong>This systematic review suggests ultrasonography can play an important role in the measurement of meniscal extrusion, with results comparable to that of MRI. However, to what extent it can differentiate between physiological and pathological extrusion requires further investigation, with an absolute cutoff value yet to be determined. Nevertheless, it is an appropriate investigation to track the progression of disease in those with meniscal pathologies or osteoarthritis. Furthermore, it is a feasible investigation to evaluate the meniscal function following surgery.</p><p><strong>Level of evidence: </strong>IV, Systematic review of level III-IV evidence.</p>\",\"PeriodicalId\":36317,\"journal\":{\"name\":\"Knee Surgery and Related Research\",\"volume\":\"36 1\",\"pages\":\"33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11514433/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery and Related Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43019-024-00236-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43019-024-00236-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:磁共振成像(MRI)是半月板挤压(ME)的首选成像方法。然而,它们可能会低估半月板随负荷而发生的变化。越来越多的证据表明,负重超声(WB US)更适合用于检查,尤其是在发现隐性挤压方面。因此,我们对超声波诊断挤压的有效性和可靠性进行了系统回顾和荟萃分析。此外,我们还探讨了腹腔镜检查是否能发现加载位置和非加载位置之间的挤压差异,以及病理膝(骨关节炎和半月板损伤)和健康膝之间的挤压差异:采用系统综述和荟萃分析首选报告项目(PRISMA)标准,利用科克伦对照试验登记、PubMed、Medline 和 Embase 进行系统综述。纳入的数据包括US测量半月板挤压(ME)的内部和相互间可靠性、其与磁共振成像(MRI)的相关性,以及影响ME的潜在因素的头对头比较[加载与卸载位置;骨关节炎(OA)或病理半月板(PM)与健康膝关节;轻度与中重度膝关节OA]。汇总数据采用随机或固定效应模型进行分析:结果:共纳入 31 项研究。研究者内部和研究者之间可靠性的类内相关系数(ICC)最低分别为0.94和0.91。US 和 MRI 之间的相关性为 (r = 0.76)。US 检测到所有膝关节在加载位置时 ME 都更大(健康,p 结论:ME 在加载位置时更大:本系统性综述表明,超声波检查在测量半月板挤压方面可发挥重要作用,其结果与核磁共振成像结果相当。然而,它能在多大程度上区分生理性挤压和病理性挤压还需要进一步研究,绝对临界值也有待确定。不过,对于半月板病变或骨关节炎患者来说,这是一项追踪疾病进展的适当检查。此外,它也是评估手术后半月板功能的可行检查方法:IV,对III-IV级证据的系统回顾。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of meniscal extrusion with ultrasonography: a systematic review and meta-analysis.

Background: Magnetic resonance imaging (MRI) is the imaging of choice for meniscal extrusion (ME). However, they may underappreciate the load-dependent changes of the meniscus. There is growing evidence that weight-bearing ultrasound (WB US) is more suitable, particularly in revealing occult extrusion. We therefore perform a systematic review and meta-analysis on the validity and reliability of US in diagnosing extrusion. Furthermore, we explored whether it detects differences in extrusion between loaded and unloaded positions and those with pathological (osteoarthritis and meniscal injury) and healthy knees.

Methods: The Cochrane Controlled Register of Trials, PubMed, Medline, and Embase were used to perform a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. Data pertaining to intra- and interrater reliability of US in measuring meniscal extrusion (ME), its correlation with magnetic resonance imaging (MRI), and head-to-head comparison of potential factors to influence ME were included [loading versus unloading position; osteoarthritis (OA) or pathological menisci (PM) versus healthy knees; mild versus moderate-severe knee OA]. Pooled data were analyzed by random or fixed-effects models.

Results: A total of 31 studies were included. Intraclass correlation coefficients (ICC) for intra- and interrater reliability were minimum 0.94 and 0.91, respectively. The correlation between US and MRI was (r = 0.76). US detected ME to be greater in the loaded position in all knees (healthy, p < 0.00001; OA, p < 0.00001; PM, p = 0.02). In all positions, US detected greater extrusion in OA (p < 0.0003) and PM knees (p = 0.006) compared with healthy controls. Furthermore, US revealed greater extrusion in moderate-severe OA knees (p < 0.00001).

Conclusions: This systematic review suggests ultrasonography can play an important role in the measurement of meniscal extrusion, with results comparable to that of MRI. However, to what extent it can differentiate between physiological and pathological extrusion requires further investigation, with an absolute cutoff value yet to be determined. Nevertheless, it is an appropriate investigation to track the progression of disease in those with meniscal pathologies or osteoarthritis. Furthermore, it is a feasible investigation to evaluate the meniscal function following surgery.

Level of evidence: IV, Systematic review of level III-IV evidence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.50
自引率
0.00%
发文量
42
审稿时长
19 weeks
期刊最新文献
A deep learning based automatic two-dimensional digital templating model for total knee arthroplasty. Current state of frailty in revision arthroplasty. Modifiable and non-modifiable risk factors affecting surgical failure after revision ACL reconstruction: a cohort study. Fractures in Oxford unicompartmental knee arthroplasty are associated with a decreased medial keel-cortex distance of the tibial implant. Increased kinematic changes in ascending compared with descending biplanar cut in open wedge high tibial osteotomy-a multibody simulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1