基于校正因子的 T10 图集是否有助于实现快速、改进的 Ktrans 计算?

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Imaging and Radiation Sciences Pub Date : 2024-10-01 DOI:10.1016/j.jmir.2024.101495
Dr Pradeep Singh Negi, Dr Amarnath Jena, Dr Shashi Bhushan Mehta
{"title":"基于校正因子的 T10 图集是否有助于实现快速、改进的 Ktrans 计算?","authors":"Dr Pradeep Singh Negi,&nbsp;Dr Amarnath Jena,&nbsp;Dr Shashi Bhushan Mehta","doi":"10.1016/j.jmir.2024.101495","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>The ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) used for Pharmacokinetic (PK) analysis is an effective method to predict benign and malignant tumor. Attempts have been made to achieve an accurate K<sup>trans</sup> by correcting T<sub>10</sub>, a major factor that influence K<sup>trans</sup> computation.</div></div><div><h3>Purpose</h3><div>The purpose of this study to develop a correction factor atlas database at every spatial-location (x,y coordinate) in both side of the mMR breast coil cuff space to improve T<sub>10</sub> homogeneity in the reference method using multiple tube phantom by SW based automation.</div></div><div><h3>Method</h3><div>Both multiple tube phantoms (61 tubes in each phantom) and patient's studies were acquired on simultaneous PET/MRI Biograph mMR system (Siemens, Erlangen, Germany) by using 4 channel mMR breast coil. Each spatial location correction factors (2916 each side, total 4392 correction factors) derived from multiple tube phantom were assign to an inhouse developed software (Radvista, version 3.2.95) that compute K<sup>trans</sup> in few seconds. A retrospective analysis of DCE-MRI data acquired for 60 seconds of 146 patients with mean age of 50 years (24-80 years) having 178 enhancing histologically proved breast lesions forms the material of the study.</div></div><div><h3>Results</h3><div>Corrected and non-corrected ROC curve analysis revealed a mean K<sup>trans</sup>, v<sub>e</sub> value of 1.52 min<sup>-1</sup>, 0.44 &amp; 1.16 min<sup>-1</sup>, 0.34 respectively. The sensitivity, specificity and overall accuracy of K<sup>trans</sup> for non-corrected data were 89.06%, 74.00% and 84.83% respectively and for corrected data it was 89.84%, 86.00%, and 88.76% respectively. The AUC of corrected data was improved to 0.927 (95% CI 0.878 to 0.960) from 0.893 (95% CI 0.839 to 0.935) for non-corrected data.</div></div><div><h3>Conclusion</h3><div>Spatially normalized T<sub>10</sub> values derived from correction factor based T<sub>10</sub> atlas in a reference method can provide a quick estimation of K<sup>trans</sup> with improved diagnostic accuracy.</div></div>","PeriodicalId":46420,"journal":{"name":"Journal of Medical Imaging and Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Does Correction factor based T10 atlas help to achieve quick and improved Ktrans computation? a feasibility study\",\"authors\":\"Dr Pradeep Singh Negi,&nbsp;Dr Amarnath Jena,&nbsp;Dr Shashi Bhushan Mehta\",\"doi\":\"10.1016/j.jmir.2024.101495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>The ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) used for Pharmacokinetic (PK) analysis is an effective method to predict benign and malignant tumor. Attempts have been made to achieve an accurate K<sup>trans</sup> by correcting T<sub>10</sub>, a major factor that influence K<sup>trans</sup> computation.</div></div><div><h3>Purpose</h3><div>The purpose of this study to develop a correction factor atlas database at every spatial-location (x,y coordinate) in both side of the mMR breast coil cuff space to improve T<sub>10</sub> homogeneity in the reference method using multiple tube phantom by SW based automation.</div></div><div><h3>Method</h3><div>Both multiple tube phantoms (61 tubes in each phantom) and patient's studies were acquired on simultaneous PET/MRI Biograph mMR system (Siemens, Erlangen, Germany) by using 4 channel mMR breast coil. Each spatial location correction factors (2916 each side, total 4392 correction factors) derived from multiple tube phantom were assign to an inhouse developed software (Radvista, version 3.2.95) that compute K<sup>trans</sup> in few seconds. A retrospective analysis of DCE-MRI data acquired for 60 seconds of 146 patients with mean age of 50 years (24-80 years) having 178 enhancing histologically proved breast lesions forms the material of the study.</div></div><div><h3>Results</h3><div>Corrected and non-corrected ROC curve analysis revealed a mean K<sup>trans</sup>, v<sub>e</sub> value of 1.52 min<sup>-1</sup>, 0.44 &amp; 1.16 min<sup>-1</sup>, 0.34 respectively. The sensitivity, specificity and overall accuracy of K<sup>trans</sup> for non-corrected data were 89.06%, 74.00% and 84.83% respectively and for corrected data it was 89.84%, 86.00%, and 88.76% respectively. The AUC of corrected data was improved to 0.927 (95% CI 0.878 to 0.960) from 0.893 (95% CI 0.839 to 0.935) for non-corrected data.</div></div><div><h3>Conclusion</h3><div>Spatially normalized T<sub>10</sub> values derived from correction factor based T<sub>10</sub> atlas in a reference method can provide a quick estimation of K<sup>trans</sup> with improved diagnostic accuracy.</div></div>\",\"PeriodicalId\":46420,\"journal\":{\"name\":\"Journal of Medical Imaging and Radiation Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging and Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1939865424002261\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1939865424002261","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

导言用于药代动力学(PK)分析的超快速动态对比增强磁共振成像(DCE-MRI)是预测良性和恶性肿瘤的有效方法。本研究的目的是在 mMR 乳房线圈袖带空间两侧的每个空间位置(x,y 坐标)上开发一个校正因子图集数据库,以便通过基于 SW 的自动化方法,在使用多管模型的参考方法中提高 T10 的均匀性。方法在 PET/MRI Biograph mMR 系统(西门子,德国埃尔兰根)上使用 4 通道 mMR 乳房线圈同时获取多管模型(每个模型中有 61 个管)和患者的研究结果。将从多管模型中得出的每个空间位置校正因子(每侧 2916 个,共 4392 个校正因子)分配给内部开发的软件(Radvista,3.2.95 版),该软件可在几秒钟内计算出 Ktrans。对 146 名平均年龄为 50 岁(24-80 岁)、有 178 个经组织学证实的乳腺增强病灶的患者 60 秒内获得的 DCE-MRI 数据进行了回顾性分析。未校正数据的 Ktrans 的灵敏度、特异性和总体准确度分别为 89.06%、74.00% 和 84.83%,校正数据的灵敏度、特异性和总体准确度分别为 89.84%、86.00% 和 88.76%。校正数据的 AUC 从未修改数据的 0.893(95% CI 0.839 至 0.935)提高到 0.927(95% CI 0.878 至 0.960)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Does Correction factor based T10 atlas help to achieve quick and improved Ktrans computation? a feasibility study

Introduction

The ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) used for Pharmacokinetic (PK) analysis is an effective method to predict benign and malignant tumor. Attempts have been made to achieve an accurate Ktrans by correcting T10, a major factor that influence Ktrans computation.

Purpose

The purpose of this study to develop a correction factor atlas database at every spatial-location (x,y coordinate) in both side of the mMR breast coil cuff space to improve T10 homogeneity in the reference method using multiple tube phantom by SW based automation.

Method

Both multiple tube phantoms (61 tubes in each phantom) and patient's studies were acquired on simultaneous PET/MRI Biograph mMR system (Siemens, Erlangen, Germany) by using 4 channel mMR breast coil. Each spatial location correction factors (2916 each side, total 4392 correction factors) derived from multiple tube phantom were assign to an inhouse developed software (Radvista, version 3.2.95) that compute Ktrans in few seconds. A retrospective analysis of DCE-MRI data acquired for 60 seconds of 146 patients with mean age of 50 years (24-80 years) having 178 enhancing histologically proved breast lesions forms the material of the study.

Results

Corrected and non-corrected ROC curve analysis revealed a mean Ktrans, ve value of 1.52 min-1, 0.44 & 1.16 min-1, 0.34 respectively. The sensitivity, specificity and overall accuracy of Ktrans for non-corrected data were 89.06%, 74.00% and 84.83% respectively and for corrected data it was 89.84%, 86.00%, and 88.76% respectively. The AUC of corrected data was improved to 0.927 (95% CI 0.878 to 0.960) from 0.893 (95% CI 0.839 to 0.935) for non-corrected data.

Conclusion

Spatially normalized T10 values derived from correction factor based T10 atlas in a reference method can provide a quick estimation of Ktrans with improved diagnostic accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Imaging and Radiation Sciences
Journal of Medical Imaging and Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
11.10%
发文量
231
审稿时长
53 days
期刊介绍: Journal of Medical Imaging and Radiation Sciences is the official peer-reviewed journal of the Canadian Association of Medical Radiation Technologists. This journal is published four times a year and is circulated to approximately 11,000 medical radiation technologists, libraries and radiology departments throughout Canada, the United States and overseas. The Journal publishes articles on recent research, new technology and techniques, professional practices, technologists viewpoints as well as relevant book reviews.
期刊最新文献
A bibliometric analysis on research authorship and collaboration patterns in radiography professional journals: A 10-year review The design and construct a website for collection and report diagnostic reference levels (DRLs) in diagnostic radiography Beyond the Machine: A Radiographer's Tale Innovative Learning Activities to Prepare Radiography Students for Final-Year Clinical Placements: An Educational Perspective Enhancing radiation therapy student's cultural competency and safety of Canadian Indigenous populations using cultural immersion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1