Sudatta Das, Kimmo Teinilä, Hilkka Timonen, Erkki Ikonen, Toni Laurila
{"title":"用微粒入液采样器结合微放电光学发射光谱实时测量亚微米气溶胶中的金属含量","authors":"Sudatta Das, Kimmo Teinilä, Hilkka Timonen, Erkki Ikonen, Toni Laurila","doi":"10.1007/s10661-024-13298-3","DOIUrl":null,"url":null,"abstract":"<div><p>The paper presents a novel technique for quantifying trace metals in aerosol samples in real time. Airborne metals were continuously collected for one week near the Baltic Sea in Finland using a particle-into-liquid sampler (PILS). The collected liquid samples were analyzed for metals using micro-discharge optical emission spectroscopy (µDOES). The micro-discharge analyzer is designed to perform real-time, on-site measurements of metal concentrations in aqueous solutions. Currently, µDOES can provide online measurements of 30 metals, with typical detection limits from 0.01 µg/m<sup>3</sup> to 0.06 µg/m<sup>3</sup> with a long-term repeatability less than 5%. The novelty of this analyzer lies in its compact design, rapid detection capabilities, and ease of operation and maintenance. Several metals, including potassium (K), calcium (Ca), sodium (Na), aluminum (Al), magnesium (Mg), and copper (Cu), were measured in the aerosol samples collected using PILS. The results indicate that this approach has significant potential for future automated online monitoring of airborne metal concentrations, facilitating investigations into their sources and daily variations. The development of real-time technologies for rapid, online, and accurate atmospheric aerosol measurements is essential for advancing climate change research. Such advancements allowing for continuous real-time data enhance our understanding of aerosol dynamics, improve source identification, and inform public health and environmental policies, ultimately contributing to more effective climate change monitoring and mitigation.</p></div>","PeriodicalId":544,"journal":{"name":"Environmental Monitoring and Assessment","volume":"196 11","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10661-024-13298-3.pdf","citationCount":"0","resultStr":"{\"title\":\"Real-time measurement of metals in submicron aerosols with particle-into-liquid sampler combined with micro-discharge optical emission spectroscopy\",\"authors\":\"Sudatta Das, Kimmo Teinilä, Hilkka Timonen, Erkki Ikonen, Toni Laurila\",\"doi\":\"10.1007/s10661-024-13298-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The paper presents a novel technique for quantifying trace metals in aerosol samples in real time. Airborne metals were continuously collected for one week near the Baltic Sea in Finland using a particle-into-liquid sampler (PILS). The collected liquid samples were analyzed for metals using micro-discharge optical emission spectroscopy (µDOES). The micro-discharge analyzer is designed to perform real-time, on-site measurements of metal concentrations in aqueous solutions. Currently, µDOES can provide online measurements of 30 metals, with typical detection limits from 0.01 µg/m<sup>3</sup> to 0.06 µg/m<sup>3</sup> with a long-term repeatability less than 5%. The novelty of this analyzer lies in its compact design, rapid detection capabilities, and ease of operation and maintenance. Several metals, including potassium (K), calcium (Ca), sodium (Na), aluminum (Al), magnesium (Mg), and copper (Cu), were measured in the aerosol samples collected using PILS. The results indicate that this approach has significant potential for future automated online monitoring of airborne metal concentrations, facilitating investigations into their sources and daily variations. The development of real-time technologies for rapid, online, and accurate atmospheric aerosol measurements is essential for advancing climate change research. Such advancements allowing for continuous real-time data enhance our understanding of aerosol dynamics, improve source identification, and inform public health and environmental policies, ultimately contributing to more effective climate change monitoring and mitigation.</p></div>\",\"PeriodicalId\":544,\"journal\":{\"name\":\"Environmental Monitoring and Assessment\",\"volume\":\"196 11\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10661-024-13298-3.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Monitoring and Assessment\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10661-024-13298-3\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Monitoring and Assessment","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s10661-024-13298-3","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Real-time measurement of metals in submicron aerosols with particle-into-liquid sampler combined with micro-discharge optical emission spectroscopy
The paper presents a novel technique for quantifying trace metals in aerosol samples in real time. Airborne metals were continuously collected for one week near the Baltic Sea in Finland using a particle-into-liquid sampler (PILS). The collected liquid samples were analyzed for metals using micro-discharge optical emission spectroscopy (µDOES). The micro-discharge analyzer is designed to perform real-time, on-site measurements of metal concentrations in aqueous solutions. Currently, µDOES can provide online measurements of 30 metals, with typical detection limits from 0.01 µg/m3 to 0.06 µg/m3 with a long-term repeatability less than 5%. The novelty of this analyzer lies in its compact design, rapid detection capabilities, and ease of operation and maintenance. Several metals, including potassium (K), calcium (Ca), sodium (Na), aluminum (Al), magnesium (Mg), and copper (Cu), were measured in the aerosol samples collected using PILS. The results indicate that this approach has significant potential for future automated online monitoring of airborne metal concentrations, facilitating investigations into their sources and daily variations. The development of real-time technologies for rapid, online, and accurate atmospheric aerosol measurements is essential for advancing climate change research. Such advancements allowing for continuous real-time data enhance our understanding of aerosol dynamics, improve source identification, and inform public health and environmental policies, ultimately contributing to more effective climate change monitoring and mitigation.
期刊介绍:
Environmental Monitoring and Assessment emphasizes technical developments and data arising from environmental monitoring and assessment, the use of scientific principles in the design of monitoring systems at the local, regional and global scales, and the use of monitoring data in assessing the consequences of natural resource management actions and pollution risks to man and the environment.