冷冻球囊与射频心房颤动消融术后自主神经变化的长期差异。

IF 8 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS JACC. Clinical electrophysiology Pub Date : 2024-10-16 DOI:10.1016/j.jacep.2024.09.003
Jason G Andrade, Richard G Bennett, Marc W Deyell, Matthew T Bennett, Jobanjit Phulka, Nathaniel M Hawkins, Tolga Aksu, Thalia S Field, Martin Aguilar, Paul Khairy, Laurent Macle
{"title":"冷冻球囊与射频心房颤动消融术后自主神经变化的长期差异。","authors":"Jason G Andrade, Richard G Bennett, Marc W Deyell, Matthew T Bennett, Jobanjit Phulka, Nathaniel M Hawkins, Tolga Aksu, Thalia S Field, Martin Aguilar, Paul Khairy, Laurent Macle","doi":"10.1016/j.jacep.2024.09.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The long-term natural history of autonomic alterations following catheter ablation of drug-refractory paroxysmal atrial fibrillation is poorly defined.</p><p><strong>Objectives: </strong>The authors sought to define the long-term impact of thermal catheter ablation on the cardiac autonomic system.</p><p><strong>Methods: </strong>The study included 346 patients with drug-refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using thermal ablation energy (radiofrequency or cryoballoon ablation). All patients underwent insertion of a Reveal LINQ implantable cardiac monitor prior to ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (HRV) (measured as the standard deviation of the average normal-to-normal), daytime heart rate, and nighttime heart rate (NHR). Longitudinal autonomic data in the 2-month period prior to the date of ablation were compared with the 3 years following ablation.</p><p><strong>Results: </strong>Following ablation, there was a significant decrease in HRV (10-20 ms; P < 0.0001) and significant increases in daytime heart rate and NHR (10 beats/min [P < 0.0001] and 7 beats/min [P < 0.0001], respectively). Changes in autonomic parameters were greatest in the first 3 months following ablation but remained significantly different from baseline for 36 months following ablation. Greater changes in NHR and HRV were associated with improved freedom from recurrent arrhythmia. The type of thermal ablation energy had no influence on the heart rate and autonomic parameters.</p><p><strong>Conclusions: </strong>Pulmonary vein isolation using thermal ablation energy results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are independent of the ablation technology employed and are associated with procedural success. (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE]; NCT01913522).</p>","PeriodicalId":14573,"journal":{"name":"JACC. Clinical electrophysiology","volume":null,"pages":null},"PeriodicalIF":8.0000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Long-Term Differences in Autonomic Alterations After Cryoballoon vs Radiofrequency Atrial Fibrillation Ablation.\",\"authors\":\"Jason G Andrade, Richard G Bennett, Marc W Deyell, Matthew T Bennett, Jobanjit Phulka, Nathaniel M Hawkins, Tolga Aksu, Thalia S Field, Martin Aguilar, Paul Khairy, Laurent Macle\",\"doi\":\"10.1016/j.jacep.2024.09.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The long-term natural history of autonomic alterations following catheter ablation of drug-refractory paroxysmal atrial fibrillation is poorly defined.</p><p><strong>Objectives: </strong>The authors sought to define the long-term impact of thermal catheter ablation on the cardiac autonomic system.</p><p><strong>Methods: </strong>The study included 346 patients with drug-refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using thermal ablation energy (radiofrequency or cryoballoon ablation). All patients underwent insertion of a Reveal LINQ implantable cardiac monitor prior to ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (HRV) (measured as the standard deviation of the average normal-to-normal), daytime heart rate, and nighttime heart rate (NHR). Longitudinal autonomic data in the 2-month period prior to the date of ablation were compared with the 3 years following ablation.</p><p><strong>Results: </strong>Following ablation, there was a significant decrease in HRV (10-20 ms; P < 0.0001) and significant increases in daytime heart rate and NHR (10 beats/min [P < 0.0001] and 7 beats/min [P < 0.0001], respectively). Changes in autonomic parameters were greatest in the first 3 months following ablation but remained significantly different from baseline for 36 months following ablation. Greater changes in NHR and HRV were associated with improved freedom from recurrent arrhythmia. The type of thermal ablation energy had no influence on the heart rate and autonomic parameters.</p><p><strong>Conclusions: </strong>Pulmonary vein isolation using thermal ablation energy results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are independent of the ablation technology employed and are associated with procedural success. (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE]; NCT01913522).</p>\",\"PeriodicalId\":14573,\"journal\":{\"name\":\"JACC. Clinical electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JACC. Clinical electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jacep.2024.09.003\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Clinical electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jacep.2024.09.003","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:药物难治性阵发性心房颤动导管消融术后自主神经改变的长期自然史尚不明确:作者试图确定热导管消融术对心脏自律神经系统的长期影响:研究纳入了346名药物难治性阵发性心房颤动患者,他们都接受了使用热消融能量(射频或冷冻球囊消融)的肺静脉隔离治疗。所有患者都在消融术前植入了 Reveal LINQ 植入式心脏监护仪。植入式心脏监护仪可连续记录体力活动、心率变异性(HRV)(以正常与正常平均值的标准偏差测量)、日间心率和夜间心率(NHR)。将消融术前 2 个月的纵向自律神经数据与消融术后 3 年的数据进行了比较:消融术后,心率变异显著降低(10-20 毫秒;P < 0.0001),日间心率和夜间心率显著增加(分别为 10 次/分钟 [P < 0.0001] 和 7 次/分钟 [P < 0.0001])。自律神经参数的变化在消融术后的头 3 个月最大,但在消融术后的 36 个月内与基线相比仍有显著差异。NHR和HRV的较大变化与心律失常复发率的改善有关。热消融能量的类型对心率和自律神经参数没有影响:结论:使用热消融能量进行肺静脉隔离会导致与自律神经功能相关的心率参数发生显著的持续变化。这些变化与所采用的消融技术无关,并与手术成功与否有关。(冷冻气球与灌注射频导管消融术:双短暴露持续时间与标准暴露持续时间[CIRCA-DOSE];NCT01913522)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Long-Term Differences in Autonomic Alterations After Cryoballoon vs Radiofrequency Atrial Fibrillation Ablation.

Background: The long-term natural history of autonomic alterations following catheter ablation of drug-refractory paroxysmal atrial fibrillation is poorly defined.

Objectives: The authors sought to define the long-term impact of thermal catheter ablation on the cardiac autonomic system.

Methods: The study included 346 patients with drug-refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using thermal ablation energy (radiofrequency or cryoballoon ablation). All patients underwent insertion of a Reveal LINQ implantable cardiac monitor prior to ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (HRV) (measured as the standard deviation of the average normal-to-normal), daytime heart rate, and nighttime heart rate (NHR). Longitudinal autonomic data in the 2-month period prior to the date of ablation were compared with the 3 years following ablation.

Results: Following ablation, there was a significant decrease in HRV (10-20 ms; P < 0.0001) and significant increases in daytime heart rate and NHR (10 beats/min [P < 0.0001] and 7 beats/min [P < 0.0001], respectively). Changes in autonomic parameters were greatest in the first 3 months following ablation but remained significantly different from baseline for 36 months following ablation. Greater changes in NHR and HRV were associated with improved freedom from recurrent arrhythmia. The type of thermal ablation energy had no influence on the heart rate and autonomic parameters.

Conclusions: Pulmonary vein isolation using thermal ablation energy results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are independent of the ablation technology employed and are associated with procedural success. (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE]; NCT01913522).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JACC. Clinical electrophysiology
JACC. Clinical electrophysiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
5.70%
发文量
250
期刊介绍: JACC: Clinical Electrophysiology is one of a family of specialist journals launched by the renowned Journal of the American College of Cardiology (JACC). It encompasses all aspects of the epidemiology, pathogenesis, diagnosis and treatment of cardiac arrhythmias. Submissions of original research and state-of-the-art reviews from cardiology, cardiovascular surgery, neurology, outcomes research, and related fields are encouraged. Experimental and preclinical work that directly relates to diagnostic or therapeutic interventions are also encouraged. In general, case reports will not be considered for publication.
期刊最新文献
Left Ventricular Summit Arrhythmias: State-of-the-Art Review of Anatomy, Mapping, and Ablation Strategies. Predictors of Clinical Success of Cardioneuroablation in Patients With Syncope: Results of a Multicenter Study. Long-Term Differences in Autonomic Alterations After Cryoballoon vs Radiofrequency Atrial Fibrillation Ablation. Shorter Premature Atrial Complex Coupling Interval Leads to Mechanical Dysfunction, Fibrosis, and AF in Swine. Visualization of Mechanisms for Myocardium-Originating Premature Ventricular Contractions With Narrow QRS Via His-Purkinje System.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1