中高度近视亚洲患者双侧植入增强型中间功能单焦点眼内透镜与-2.00 D和散光的比较。

IF 4.1 1区 医学 Q1 OPHTHALMOLOGY Eye and Vision Pub Date : 2024-11-01 DOI:10.1186/s40662-024-00410-4
Yoo Young Jeon, Hayoung Lee, Kyu Sang Eah, Nahyun Park, Ho Seok Chung, Jae Yong Kim, Hungwon Tchah, Hun Lee
{"title":"中高度近视亚洲患者双侧植入增强型中间功能单焦点眼内透镜与-2.00 D和散光的比较。","authors":"Yoo Young Jeon, Hayoung Lee, Kyu Sang Eah, Nahyun Park, Ho Seok Chung, Jae Yong Kim, Hungwon Tchah, Hun Lee","doi":"10.1186/s40662-024-00410-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the outcomes of bilateral implantation of enhanced monofocal intraocular lenses (IOLs, ICB00) with a - 2.00 diopter (D) target in patients with moderate to high myopia and to compare the clinical outcomes of a - 2.00 D binocular target with an emmetropia target in patients who underwent cataract surgery.</p><p><strong>Methods: </strong>In this retrospective study, we reviewed the medical records of patients who underwent uncomplicated phacoemulsification with ICB00 IOL implantation. Emmetropia (Group 1) and - 2.00 D (Group 2) were targeted in 60 and 20 eyes of 30 and 10 patients, respectively. Three months after surgery, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA) were measured. Defocus curves were measured under the photopic condition by intervals of 0.50 D from + 0.50 D to - 4.00 D.</p><p><strong>Results: </strong>The postoperative binocular logMAR UDVA, UIVA, and UNVA were 0.01 ± 0.03, 0.08 ± 0.11, and 0.33 ± 0.15 in Group 1 and 0.31 ± 0.13, 0.04 ± 0.05, and 0.11 ± 0.07 in Group 2, respectively. Group 2 showed a significantly superior postoperative binocular UNVA (P = 0.027) and inferior binocular UDVA (P = 0.003) than Group 1. Binocular UIVA and CDVA did not significantly differ between the groups although UIVA was better in Group 2 than in Group 1. Near glasses were needed by 66% of Group 1 and 0% of Group 2.</p><p><strong>Conclusions: </strong>Bilateral implantation of ICB00 IOL with - 2.00 D of residual myopia is suitable for patients with moderate to high myopia to improve UDVA, UIVA, and UNVA.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"11 1","pages":"42"},"PeriodicalIF":4.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11529253/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of bilateral implantation of monofocal intraocular lenses with enhanced intermediate function targeting with - 2.00 D and emmetropia in moderate to high myopic Asian patients.\",\"authors\":\"Yoo Young Jeon, Hayoung Lee, Kyu Sang Eah, Nahyun Park, Ho Seok Chung, Jae Yong Kim, Hungwon Tchah, Hun Lee\",\"doi\":\"10.1186/s40662-024-00410-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate the outcomes of bilateral implantation of enhanced monofocal intraocular lenses (IOLs, ICB00) with a - 2.00 diopter (D) target in patients with moderate to high myopia and to compare the clinical outcomes of a - 2.00 D binocular target with an emmetropia target in patients who underwent cataract surgery.</p><p><strong>Methods: </strong>In this retrospective study, we reviewed the medical records of patients who underwent uncomplicated phacoemulsification with ICB00 IOL implantation. Emmetropia (Group 1) and - 2.00 D (Group 2) were targeted in 60 and 20 eyes of 30 and 10 patients, respectively. Three months after surgery, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA) were measured. Defocus curves were measured under the photopic condition by intervals of 0.50 D from + 0.50 D to - 4.00 D.</p><p><strong>Results: </strong>The postoperative binocular logMAR UDVA, UIVA, and UNVA were 0.01 ± 0.03, 0.08 ± 0.11, and 0.33 ± 0.15 in Group 1 and 0.31 ± 0.13, 0.04 ± 0.05, and 0.11 ± 0.07 in Group 2, respectively. Group 2 showed a significantly superior postoperative binocular UNVA (P = 0.027) and inferior binocular UDVA (P = 0.003) than Group 1. Binocular UIVA and CDVA did not significantly differ between the groups although UIVA was better in Group 2 than in Group 1. Near glasses were needed by 66% of Group 1 and 0% of Group 2.</p><p><strong>Conclusions: </strong>Bilateral implantation of ICB00 IOL with - 2.00 D of residual myopia is suitable for patients with moderate to high myopia to improve UDVA, UIVA, and UNVA.</p>\",\"PeriodicalId\":12194,\"journal\":{\"name\":\"Eye and Vision\",\"volume\":\"11 1\",\"pages\":\"42\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11529253/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-024-00410-4\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-024-00410-4","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:目的:研究中高度近视患者双侧植入- 2.00屈光度(D)目标的增强型单焦点眼内人工晶体(IOL,ICB00)的疗效,并比较接受白内障手术的患者中- 2.00 D双目目标与屈光度目标的临床疗效:在这项回顾性研究中,我们回顾了接受无并发症超声乳化术并植入 ICB00 人工晶体的患者的病历。分别有 30 名和 10 名患者的 60 只眼睛和 20 只眼睛出现了视力下降(第 1 组)和- 2.00 D(第 2 组)。术后三个月,测量未矫正远视力(UDVA)、矫正远视力(CDVA)、未矫正中视力(UIVA)和未矫正近视力(UNVA)。在有光条件下,测量离焦曲线,从 + 0.50 D 到 - 4.00 D,间隔为 0.50 D:结果:第 1 组术后双眼对数马氏 UDVA、UIVA 和 UNVA 分别为 0.01 ± 0.03、0.08 ± 0.11 和 0.33 ± 0.15,第 2 组分别为 0.31 ± 0.13、0.04 ± 0.05 和 0.11 ± 0.07。第 2 组的术后双眼 UNVA(P = 0.027)和双眼 UDVA(P = 0.003)明显优于第 1 组,而双眼 UIVA 和 CDVA 在各组间无明显差异,但第 2 组的 UIVA 优于第 1 组:结论:残余近视度数为 - 2.00 D 的 ICB00 IOL 双侧植入术适合中高度近视患者,可改善 UDVA、UIVA 和 UNVA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of bilateral implantation of monofocal intraocular lenses with enhanced intermediate function targeting with - 2.00 D and emmetropia in moderate to high myopic Asian patients.

Background: To investigate the outcomes of bilateral implantation of enhanced monofocal intraocular lenses (IOLs, ICB00) with a - 2.00 diopter (D) target in patients with moderate to high myopia and to compare the clinical outcomes of a - 2.00 D binocular target with an emmetropia target in patients who underwent cataract surgery.

Methods: In this retrospective study, we reviewed the medical records of patients who underwent uncomplicated phacoemulsification with ICB00 IOL implantation. Emmetropia (Group 1) and - 2.00 D (Group 2) were targeted in 60 and 20 eyes of 30 and 10 patients, respectively. Three months after surgery, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA) were measured. Defocus curves were measured under the photopic condition by intervals of 0.50 D from + 0.50 D to - 4.00 D.

Results: The postoperative binocular logMAR UDVA, UIVA, and UNVA were 0.01 ± 0.03, 0.08 ± 0.11, and 0.33 ± 0.15 in Group 1 and 0.31 ± 0.13, 0.04 ± 0.05, and 0.11 ± 0.07 in Group 2, respectively. Group 2 showed a significantly superior postoperative binocular UNVA (P = 0.027) and inferior binocular UDVA (P = 0.003) than Group 1. Binocular UIVA and CDVA did not significantly differ between the groups although UIVA was better in Group 2 than in Group 1. Near glasses were needed by 66% of Group 1 and 0% of Group 2.

Conclusions: Bilateral implantation of ICB00 IOL with - 2.00 D of residual myopia is suitable for patients with moderate to high myopia to improve UDVA, UIVA, and UNVA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
期刊最新文献
Levodopa is associated with reduced development of new-onset geographic atrophy in patients with age-related macular degeneration. A review of the application of in-vivo confocal microscopy on conjunctival diseases. Comparison of bilateral implantation of monofocal intraocular lenses with enhanced intermediate function targeting with - 2.00 D and emmetropia in moderate to high myopic Asian patients. Visual and patient reported outcomes provided by a refractive multifocal intraocular lens based on continuous transitional focus. Inflammatory and genomic interactions within keratoconus susceptible patients: a nationwide registered case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1