Hatem M El-Damanhoury, Betul Rahman, Soumya Sheela, Hien C Ngo
{"title":"二胺氟化银溶液的牙本质小管闭塞性和牙本质渗透性功效。","authors":"Hatem M El-Damanhoury, Betul Rahman, Soumya Sheela, Hien C Ngo","doi":"10.1111/idh.12854","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This in vitro study compared the effect of two commercially available silver diamine fluoride (SDF) products on dentinal tubule (DT) occlusion and dentin permeability.</p><p><strong>Methods: </strong>Sixty-six dentin discs (1.0 mm thick) were divided equally into six groups: acid-etched with no treatment (negative control-NC), etched and sealed with nail varnish (positive control-PC), non-etched and treated with Advantage Arrest (AA), non-etched and treated with Topamine (TP), etched and treated with AA, and etched and treated with TP. Eight specimens from each group were tested for permeability using the dye percolation method. The remaining three samples from each group were assessed for dentinal tubule occlusion, depth of SDF penetration, and elemental analysis using a scanning electron microscope coupled with an energy-dispersive X-ray (SEM/EDX) system. One-way ANOVA and Tukey's post hoc test were used to analyze the results.</p><p><strong>Results: </strong>TP exhibited lower (p < 0.05) dye percolation compared to AA. While both SDF materials showed a statistically similar (p > 0.05) penetration depth in the DT, none of them had the ability to completely occlude all the DTs. AA exhibited more silver and fluoride ion deposition on etched dentin than TP, and both materials showed a similar increase in the deposition of Ca and P compared to NC.</p><p><strong>Conclusions: </strong>Whereas the effectiveness of dentin tubule (DT) occlusion varies based on the material used, both tested SDF products exhibit the capability to seal dentinal tubules, decrease dentin permeability, and promote dentin remineralization. These findings suggest their potential advantage in managing dentin hypersensitivity.</p>","PeriodicalId":13791,"journal":{"name":"International journal of dental hygiene","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dentinal Tubule Occlusion and Dentin Permeability Efficacy of Silver Diamine Fluoride Solutions.\",\"authors\":\"Hatem M El-Damanhoury, Betul Rahman, Soumya Sheela, Hien C Ngo\",\"doi\":\"10.1111/idh.12854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>This in vitro study compared the effect of two commercially available silver diamine fluoride (SDF) products on dentinal tubule (DT) occlusion and dentin permeability.</p><p><strong>Methods: </strong>Sixty-six dentin discs (1.0 mm thick) were divided equally into six groups: acid-etched with no treatment (negative control-NC), etched and sealed with nail varnish (positive control-PC), non-etched and treated with Advantage Arrest (AA), non-etched and treated with Topamine (TP), etched and treated with AA, and etched and treated with TP. Eight specimens from each group were tested for permeability using the dye percolation method. The remaining three samples from each group were assessed for dentinal tubule occlusion, depth of SDF penetration, and elemental analysis using a scanning electron microscope coupled with an energy-dispersive X-ray (SEM/EDX) system. One-way ANOVA and Tukey's post hoc test were used to analyze the results.</p><p><strong>Results: </strong>TP exhibited lower (p < 0.05) dye percolation compared to AA. While both SDF materials showed a statistically similar (p > 0.05) penetration depth in the DT, none of them had the ability to completely occlude all the DTs. AA exhibited more silver and fluoride ion deposition on etched dentin than TP, and both materials showed a similar increase in the deposition of Ca and P compared to NC.</p><p><strong>Conclusions: </strong>Whereas the effectiveness of dentin tubule (DT) occlusion varies based on the material used, both tested SDF products exhibit the capability to seal dentinal tubules, decrease dentin permeability, and promote dentin remineralization. These findings suggest their potential advantage in managing dentin hypersensitivity.</p>\",\"PeriodicalId\":13791,\"journal\":{\"name\":\"International journal of dental hygiene\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of dental hygiene\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/idh.12854\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of dental hygiene","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/idh.12854","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:本体外研究比较了两种市售二胺氟化银(SDF)产品对牙本质小管(DT)咬合和牙本质渗透性的影响:将 66 个牙本质圆片(1.0 毫米厚)平均分成六组:酸蚀后未处理组(阴性对照组-NC)、蚀刻后用指甲油密封组(阳性对照组-PC)、未蚀刻后用 Advantage Arrest (AA) 处理组、未蚀刻后用 Topamine (TP) 处理组、蚀刻后用 AA 处理组和蚀刻后用 TP 处理组。使用染料渗滤法对每组中的八个试样进行了渗透性测试。使用扫描电子显微镜和能量色散 X 射线(SEM/EDX)系统对每组的其余三个样本进行牙本质小管闭塞、SDF 渗透深度和元素分析评估。分析结果采用单因素方差分析和 Tukey 后检验:TP 在 DT 中的渗透深度较低(p 0.05),它们都无法完全堵塞所有 DT。与 TP 相比,AA 在蚀刻牙本质上表现出更多的银离子和氟离子沉积,与 NC 相比,两种材料在 Ca 和 P 的沉积方面表现出相似的增加:虽然牙本质小管(DT)闭塞的效果因所用材料而异,但两种测试过的 SDF 产品都具有封闭牙本质小管、降低牙本质渗透性和促进牙本质再矿化的能力。这些研究结果表明了它们在控制牙本质过敏方面的潜在优势。
Dentinal Tubule Occlusion and Dentin Permeability Efficacy of Silver Diamine Fluoride Solutions.
Aim: This in vitro study compared the effect of two commercially available silver diamine fluoride (SDF) products on dentinal tubule (DT) occlusion and dentin permeability.
Methods: Sixty-six dentin discs (1.0 mm thick) were divided equally into six groups: acid-etched with no treatment (negative control-NC), etched and sealed with nail varnish (positive control-PC), non-etched and treated with Advantage Arrest (AA), non-etched and treated with Topamine (TP), etched and treated with AA, and etched and treated with TP. Eight specimens from each group were tested for permeability using the dye percolation method. The remaining three samples from each group were assessed for dentinal tubule occlusion, depth of SDF penetration, and elemental analysis using a scanning electron microscope coupled with an energy-dispersive X-ray (SEM/EDX) system. One-way ANOVA and Tukey's post hoc test were used to analyze the results.
Results: TP exhibited lower (p < 0.05) dye percolation compared to AA. While both SDF materials showed a statistically similar (p > 0.05) penetration depth in the DT, none of them had the ability to completely occlude all the DTs. AA exhibited more silver and fluoride ion deposition on etched dentin than TP, and both materials showed a similar increase in the deposition of Ca and P compared to NC.
Conclusions: Whereas the effectiveness of dentin tubule (DT) occlusion varies based on the material used, both tested SDF products exhibit the capability to seal dentinal tubules, decrease dentin permeability, and promote dentin remineralization. These findings suggest their potential advantage in managing dentin hypersensitivity.
期刊介绍:
International Journal of Dental Hygiene is the official scientific peer-reviewed journal of the International Federation of Dental Hygienists (IFDH). The journal brings the latest scientific news, high quality commissioned reviews as well as clinical, professional and educational developmental and legislative news to the profession world-wide. Thus, it acts as a forum for exchange of relevant information and enhancement of the profession with the purpose of promoting oral health for patients and communities.
The aim of the International Journal of Dental Hygiene is to provide a forum for exchange of scientific knowledge in the field of oral health and dental hygiene. A further aim is to support and facilitate the application of new knowledge into clinical practice. The journal welcomes original research, reviews and case reports as well as clinical, professional, educational and legislative news to the profession world-wide.