使用 99mTc-HMDP 成像诊断和评估他脒治疗后的心脏淀粉样变性的单中心分析。

IF 1.3 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Nuclear Medicine Communications Pub Date : 2024-10-31 DOI:10.1097/MNM.0000000000001922
Ryuta Egi, Yohji Matsusaka, Kaho Watanabe, Akira Seto, Ichiro Matsunari, Takahide Arai, Shintaro Nakano, Ichiei Kuji
{"title":"使用 99mTc-HMDP 成像诊断和评估他脒治疗后的心脏淀粉样变性的单中心分析。","authors":"Ryuta Egi, Yohji Matsusaka, Kaho Watanabe, Akira Seto, Ichiro Matsunari, Takahide Arai, Shintaro Nakano, Ichiei Kuji","doi":"10.1097/MNM.0000000000001922","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to evaluate the diagnostic performance of 99mTc-hydroxymethylene diphosphonate (99mTc-HMDP) imaging for cardiac amyloidosis and to demonstrate changes in cardiac uptake of 99mTc-HMDP after tafamidis treatment.</p><p><strong>Methods: </strong>Seventy-five patients with suspected cardiac amyloidosis who underwent 99mTc-HMDP imaging were included. We compared visual Perugini grades and semiquantitative heart-to-contralateral (H/CL) area ratios, myocardial maximum standardized uptake value (SUVmax), and peak of SUV (SUVpeak) between cardiac transthyretin amyloidosis (ATTR) and amyloid light-chain amyloidosis (AL). Comparison of interobserver reproducibility between H/CL ratios and myocardial SUVmax/SUVpeak was performed. H/CL ratio of 99mTc-HMDP and myocardial SUVmax/SUVpeak were compared before and after tafamidis administration for cardiac wild-type ATTR.</p><p><strong>Results: </strong>Among 75 patients, 20 patients (26.7%) were visually positive based on Perugini grade. Fifteen and three patients were pathologically identified as cardiac ATTR and AL, respectively. ATTR group (n = 15) had significantly higher H/CL ratios of 99mTc-HMDP than AL group (n = 3) (P = 0.003). ATTR group (n = 15) had significantly higher myocardial SUVmax/SUVpeak of 99mTc-HMDP than AL group (n = 2) (P = 0.015). Myocardial SUVmax/SUVpeak had better interobserver reproducibility than H/CL ratios. After tafamidis treatment for cardiac wild-type ATTR, the decrease in myocardial SUVpeak was significant but not in H/CL ratios and myocardial SUVmax.</p><p><strong>Conclusion: </strong>H/CL ratio and SUVmax/SUVpeak in 99mTc-HMDP imaging were useful for diagnosing cardiac ATTR. Myocardial SUVpeak may be useful for monitoring changes in cardiac uptake after tafamidis treatment for cardiac ATTR.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-center analysis of cardiac amyloidosis using 99mTc-HMDP imaging for diagnosis and evaluation after tafamidis treatment.\",\"authors\":\"Ryuta Egi, Yohji Matsusaka, Kaho Watanabe, Akira Seto, Ichiro Matsunari, Takahide Arai, Shintaro Nakano, Ichiei Kuji\",\"doi\":\"10.1097/MNM.0000000000001922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to evaluate the diagnostic performance of 99mTc-hydroxymethylene diphosphonate (99mTc-HMDP) imaging for cardiac amyloidosis and to demonstrate changes in cardiac uptake of 99mTc-HMDP after tafamidis treatment.</p><p><strong>Methods: </strong>Seventy-five patients with suspected cardiac amyloidosis who underwent 99mTc-HMDP imaging were included. We compared visual Perugini grades and semiquantitative heart-to-contralateral (H/CL) area ratios, myocardial maximum standardized uptake value (SUVmax), and peak of SUV (SUVpeak) between cardiac transthyretin amyloidosis (ATTR) and amyloid light-chain amyloidosis (AL). Comparison of interobserver reproducibility between H/CL ratios and myocardial SUVmax/SUVpeak was performed. H/CL ratio of 99mTc-HMDP and myocardial SUVmax/SUVpeak were compared before and after tafamidis administration for cardiac wild-type ATTR.</p><p><strong>Results: </strong>Among 75 patients, 20 patients (26.7%) were visually positive based on Perugini grade. Fifteen and three patients were pathologically identified as cardiac ATTR and AL, respectively. ATTR group (n = 15) had significantly higher H/CL ratios of 99mTc-HMDP than AL group (n = 3) (P = 0.003). ATTR group (n = 15) had significantly higher myocardial SUVmax/SUVpeak of 99mTc-HMDP than AL group (n = 2) (P = 0.015). Myocardial SUVmax/SUVpeak had better interobserver reproducibility than H/CL ratios. After tafamidis treatment for cardiac wild-type ATTR, the decrease in myocardial SUVpeak was significant but not in H/CL ratios and myocardial SUVmax.</p><p><strong>Conclusion: </strong>H/CL ratio and SUVmax/SUVpeak in 99mTc-HMDP imaging were useful for diagnosing cardiac ATTR. Myocardial SUVpeak may be useful for monitoring changes in cardiac uptake after tafamidis treatment for cardiac ATTR.</p>\",\"PeriodicalId\":19708,\"journal\":{\"name\":\"Nuclear Medicine Communications\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Medicine Communications\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MNM.0000000000001922\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000001922","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在评估 99mTc-hydroxymethylene diphosphonate(99mTc-HMDP)成像对心脏淀粉样变性的诊断性能,并证明他非米迪治疗后 99mTc-HMDP 的心脏摄取量的变化:方法:纳入75名接受99m锝-HMDP成像检查的疑似心脏淀粉样变性患者。我们比较了心脏转甲状腺素淀粉样变性(ATTR)和淀粉样轻链淀粉样变性(AL)的视觉佩鲁吉尼分级和半定量心对侧(H/CL)面积比、心肌最大标准化摄取值(SUVmax)和SUV峰值(SUVpeak)。比较了 H/CL 比值和心肌 SUVmax/SUVpeak 在观察者之间的再现性。对心脏野生型ATTR患者服用他非米迪前后,99m锝-HMDP的H/CL比值和心肌SUVmax/SUVpeak进行比较:75例患者中,20例(26.7%)根据佩鲁吉尼分级为肉眼阳性。分别有 15 名和 3 名患者经病理鉴定为心脏 ATTR 和 AL。ATTR 组(n = 15)的 99mTc-HMDP H/CL 比率明显高于 AL 组(n = 3)(P = 0.003)。ATTR 组(n = 15)的 99mTc-HMDP 心肌 SUVmax/SUVpeak 明显高于 AL 组(n = 2)(P = 0.015)。与 H/CL 比值相比,心肌 SUVmax/SUVpeak 在观察者之间具有更好的可重复性。他法米迪治疗心脏野生型ATTR后,心肌SUVpeak下降显著,但H/CL比值和心肌SUVmax下降不显著:结论:99m锝-HMDP成像中的H/CL比值和SUVmax/SUVpeak有助于诊断心脏ATR。心肌 SUVpeak 可用于监测他法米迪治疗心脏 ATTR 后心脏摄取的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Single-center analysis of cardiac amyloidosis using 99mTc-HMDP imaging for diagnosis and evaluation after tafamidis treatment.

Objective: This study aimed to evaluate the diagnostic performance of 99mTc-hydroxymethylene diphosphonate (99mTc-HMDP) imaging for cardiac amyloidosis and to demonstrate changes in cardiac uptake of 99mTc-HMDP after tafamidis treatment.

Methods: Seventy-five patients with suspected cardiac amyloidosis who underwent 99mTc-HMDP imaging were included. We compared visual Perugini grades and semiquantitative heart-to-contralateral (H/CL) area ratios, myocardial maximum standardized uptake value (SUVmax), and peak of SUV (SUVpeak) between cardiac transthyretin amyloidosis (ATTR) and amyloid light-chain amyloidosis (AL). Comparison of interobserver reproducibility between H/CL ratios and myocardial SUVmax/SUVpeak was performed. H/CL ratio of 99mTc-HMDP and myocardial SUVmax/SUVpeak were compared before and after tafamidis administration for cardiac wild-type ATTR.

Results: Among 75 patients, 20 patients (26.7%) were visually positive based on Perugini grade. Fifteen and three patients were pathologically identified as cardiac ATTR and AL, respectively. ATTR group (n = 15) had significantly higher H/CL ratios of 99mTc-HMDP than AL group (n = 3) (P = 0.003). ATTR group (n = 15) had significantly higher myocardial SUVmax/SUVpeak of 99mTc-HMDP than AL group (n = 2) (P = 0.015). Myocardial SUVmax/SUVpeak had better interobserver reproducibility than H/CL ratios. After tafamidis treatment for cardiac wild-type ATTR, the decrease in myocardial SUVpeak was significant but not in H/CL ratios and myocardial SUVmax.

Conclusion: H/CL ratio and SUVmax/SUVpeak in 99mTc-HMDP imaging were useful for diagnosing cardiac ATTR. Myocardial SUVpeak may be useful for monitoring changes in cardiac uptake after tafamidis treatment for cardiac ATTR.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
期刊最新文献
Correlation between 18 F-FDG PET/CT metabolic parameters and microvascular invasion before liver transplantation in patients with hepatocellular carcinoma. Evaluation of jaw pathologies of patients with medication-related osteonecrosis of the jaw using a computer program to assess the bone scan index: comparison of standardized uptake values with bone SPECT/CT. Parametric imaging in salivary gland scintigraphy. Predicting invasiveness of ground-glass nodules in lung adenocarcinoma: based on preoperative 18 F-fluorodeoxyglucose PET/computed tomography and high-resolution computed tomography. SeHCAT retention measurements may be compromised by traces of 177 Lu/ 177m Lu more than 90 days after 177 Lu-DOTATATE was administered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1