热力学老化对垂直边缘间隙和抗折性的影响:Bioflx 和传统儿科牙冠的比较研究。

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2024-11-01 DOI:10.1186/s12903-024-05053-4
Asmaa Ali Emam Abo-Elsoud, Eman Mohamed Mohamady, Noha El-Sayed Fathi Abdou
{"title":"热力学老化对垂直边缘间隙和抗折性的影响:Bioflx 和传统儿科牙冠的比较研究。","authors":"Asmaa Ali Emam Abo-Elsoud, Eman Mohamed Mohamady, Noha El-Sayed Fathi Abdou","doi":"10.1186/s12903-024-05053-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Various types of crowns are used for full-coverage restoration of primary teeth affected by caries, developmental defects, or after pulp therapy. Prefabricated Stainless Steel and Zirconia crowns are commonly utilized. Bioflx crowns, which blend the properties of Stainless Steel and Zirconia, provide a flexible and aesthetically pleasing alternative.</p><p><strong>Aim: </strong>This study aimed to evaluate the vertical marginal gap and fracture resistance of Bioflx pediatric crowns compared to Zirconia and Stainless Steel crowns following thermomechanical aging.</p><p><strong>Methods: </strong>This in-vitro study was conducted using mandibular second primary crowns of three different materials (n = 30). Crowns were divided into three groups; Zirconia crowns group (n = 10, Nu Smile, USA), Bioflx crowns group (n = 10, Nu Smile, USA) and Stainless Steel crowns group (n = 10, Nu Smile, USA). The crowns were cemented onto standardized acrylic resin dies and subjected to thermomechanical aging. Vertical marginal gap measurements were obtained using a USB digital microscope with an integrated camera, while fracture resistance was assessed with a universal testing machine. Data were analyzed for outliers and tested for normality using the Shapiro-Wilk or Kolmogorov-Smirnov tests, with statistical significance set at 0.05.</p><p><strong>Results: </strong>Significant differences were observed in the vertical marginal gaps among the groups after cementation and thermomechanical aging (P = 0.013 and P = 0.001, respectively). Zirconia crowns exhibited the largest average marginal gap, followed by Bioflx and Stainless Steel crowns. Stainless steel crowns demonstrated the highest fracture resistance, followed by Bioflx crowns, while Zirconia crowns showed the lowest.</p><p><strong>Conclusions: </strong>Bioflx crowns exhibit the largest vertical marginal gap but show greater fracture resistance compared to Zirconia crowns, although they are still less resistant than Stainless Steel crowns after undergoing thermomechanical aging.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"24 1","pages":"1334"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11529303/pdf/","citationCount":"0","resultStr":"{\"title\":\"Thermomechanical aging effects on vertical marginal gap and fracture resistance: a comparative study of Bioflx and traditional pediatric crowns.\",\"authors\":\"Asmaa Ali Emam Abo-Elsoud, Eman Mohamed Mohamady, Noha El-Sayed Fathi Abdou\",\"doi\":\"10.1186/s12903-024-05053-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Various types of crowns are used for full-coverage restoration of primary teeth affected by caries, developmental defects, or after pulp therapy. Prefabricated Stainless Steel and Zirconia crowns are commonly utilized. Bioflx crowns, which blend the properties of Stainless Steel and Zirconia, provide a flexible and aesthetically pleasing alternative.</p><p><strong>Aim: </strong>This study aimed to evaluate the vertical marginal gap and fracture resistance of Bioflx pediatric crowns compared to Zirconia and Stainless Steel crowns following thermomechanical aging.</p><p><strong>Methods: </strong>This in-vitro study was conducted using mandibular second primary crowns of three different materials (n = 30). Crowns were divided into three groups; Zirconia crowns group (n = 10, Nu Smile, USA), Bioflx crowns group (n = 10, Nu Smile, USA) and Stainless Steel crowns group (n = 10, Nu Smile, USA). The crowns were cemented onto standardized acrylic resin dies and subjected to thermomechanical aging. Vertical marginal gap measurements were obtained using a USB digital microscope with an integrated camera, while fracture resistance was assessed with a universal testing machine. Data were analyzed for outliers and tested for normality using the Shapiro-Wilk or Kolmogorov-Smirnov tests, with statistical significance set at 0.05.</p><p><strong>Results: </strong>Significant differences were observed in the vertical marginal gaps among the groups after cementation and thermomechanical aging (P = 0.013 and P = 0.001, respectively). Zirconia crowns exhibited the largest average marginal gap, followed by Bioflx and Stainless Steel crowns. Stainless steel crowns demonstrated the highest fracture resistance, followed by Bioflx crowns, while Zirconia crowns showed the lowest.</p><p><strong>Conclusions: </strong>Bioflx crowns exhibit the largest vertical marginal gap but show greater fracture resistance compared to Zirconia crowns, although they are still less resistant than Stainless Steel crowns after undergoing thermomechanical aging.</p>\",\"PeriodicalId\":9072,\"journal\":{\"name\":\"BMC Oral Health\",\"volume\":\"24 1\",\"pages\":\"1334\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11529303/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Oral Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12903-024-05053-4\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-024-05053-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:各种类型的牙冠用于全覆盖修复受龋齿、发育缺陷或牙髓治疗后影响的基牙。通常使用的是预制不锈钢和氧化锆牙冠。目的:本研究旨在评估 Bioflx 儿童牙冠与氧化锆和不锈钢牙冠相比,在热机械老化后的垂直边缘间隙和抗折性:这项体外研究使用了三种不同材料的下颌第二主冠(n = 30)。牙冠分为三组:氧化锆牙冠组(n = 10,美国 Nu Smile 公司)、Bioflx 牙冠组(n = 10,美国 Nu Smile 公司)和不锈钢牙冠组(n = 10,美国 Nu Smile 公司)。牙冠粘结在标准的丙烯酸树脂模具上,并进行热机械老化。使用带集成摄像头的 USB 数码显微镜测量垂直边缘间隙,使用万能试验机评估抗折性。使用 Shapiro-Wilk 或 Kolmogorov-Smirnov 检验对数据进行异常值分析和正态性检验,统计显著性设定为 0.05:结果:粘接和热机械老化后,各组间的垂直边缘间隙存在显著差异(分别为 P = 0.013 和 P = 0.001)。氧化锆冠的平均边缘间隙最大,其次是 Bioflx 冠和不锈钢冠。不锈钢冠的抗折性最高,其次是 Bioflx 冠,而氧化锆冠的抗折性最低:结论:Bioflx 牙冠的垂直边缘间隙最大,但与氧化锆牙冠相比,其抗折性更强,不过在经过热机械老化后,其抗折性仍低于不锈钢牙冠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermomechanical aging effects on vertical marginal gap and fracture resistance: a comparative study of Bioflx and traditional pediatric crowns.

Background: Various types of crowns are used for full-coverage restoration of primary teeth affected by caries, developmental defects, or after pulp therapy. Prefabricated Stainless Steel and Zirconia crowns are commonly utilized. Bioflx crowns, which blend the properties of Stainless Steel and Zirconia, provide a flexible and aesthetically pleasing alternative.

Aim: This study aimed to evaluate the vertical marginal gap and fracture resistance of Bioflx pediatric crowns compared to Zirconia and Stainless Steel crowns following thermomechanical aging.

Methods: This in-vitro study was conducted using mandibular second primary crowns of three different materials (n = 30). Crowns were divided into three groups; Zirconia crowns group (n = 10, Nu Smile, USA), Bioflx crowns group (n = 10, Nu Smile, USA) and Stainless Steel crowns group (n = 10, Nu Smile, USA). The crowns were cemented onto standardized acrylic resin dies and subjected to thermomechanical aging. Vertical marginal gap measurements were obtained using a USB digital microscope with an integrated camera, while fracture resistance was assessed with a universal testing machine. Data were analyzed for outliers and tested for normality using the Shapiro-Wilk or Kolmogorov-Smirnov tests, with statistical significance set at 0.05.

Results: Significant differences were observed in the vertical marginal gaps among the groups after cementation and thermomechanical aging (P = 0.013 and P = 0.001, respectively). Zirconia crowns exhibited the largest average marginal gap, followed by Bioflx and Stainless Steel crowns. Stainless steel crowns demonstrated the highest fracture resistance, followed by Bioflx crowns, while Zirconia crowns showed the lowest.

Conclusions: Bioflx crowns exhibit the largest vertical marginal gap but show greater fracture resistance compared to Zirconia crowns, although they are still less resistant than Stainless Steel crowns after undergoing thermomechanical aging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Evaluating practices toward dental health among primary school children in Rwanda. Sleep disorders as independent predictors of taste dysfunction risk. Correction: The effect of root orientation on inferior alveolar nerve injury after extraction of impacted mandibular third molars based on propensity score‑matched analysis: a retrospective cohort study. Do randomised clinical trials on dental caries adopt Open Science practices? Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1