欧洲部分患者鼻腔解剖变异的特征及其对鼻内给药的影响。

IF 5.3 2区 医学 Q1 PHARMACOLOGY & PHARMACY International Journal of Pharmaceutics Pub Date : 2024-10-26 DOI:10.1016/j.ijpharm.2024.124851
Mike Pasteur , Guillaume Arsouze , Guy Ilango , Déborah Le Pennec , Dimitri Kulker , Anaïs Heyraud , Jean-Philippe Cottier , Charles Aussedat , Nathalie Heuzé-Vourc’h , Virginie Hervé , Sandrine Le Guellec
{"title":"欧洲部分患者鼻腔解剖变异的特征及其对鼻内给药的影响。","authors":"Mike Pasteur ,&nbsp;Guillaume Arsouze ,&nbsp;Guy Ilango ,&nbsp;Déborah Le Pennec ,&nbsp;Dimitri Kulker ,&nbsp;Anaïs Heyraud ,&nbsp;Jean-Philippe Cottier ,&nbsp;Charles Aussedat ,&nbsp;Nathalie Heuzé-Vourc’h ,&nbsp;Virginie Hervé ,&nbsp;Sandrine Le Guellec","doi":"10.1016/j.ijpharm.2024.124851","DOIUrl":null,"url":null,"abstract":"<div><div>Anatomical 3D-printed nasal casts are valuable models to investigate intranasal drug deposition, providing preclinical data that cannot be obtained in animal models. However, these models are limited since they are often derived from a single patient or represent a mean of several groups. The present study aimed to better characterize the anatomical differences of the nasal cavity in a European sub-population and to assess the potential impact of anatomical variations on intranasal deposition by medical devices. Ninety-eight cranial computed tomography scans of patients were selected and analyzed in 2D and 3D conformations. They showed symmetry of cavities and a high level of heterogeneity of measurements, especially volume and area, in the population. Three anatomical groups with distinct nasal geometry were identified and 3D nasal casts of the most representative patient of each group were printed. Fluorescein was administered using three medical devices: a nasal spray, a sonic jet nebulizer and a prototype mesh-nebulizer. The deposition profiles were compared with the Aeronose® as a reference. Our results show that anatomical variations influenced the deposition profiles depending on the device, with a higher variation with spray and the mesh-nebulizer. This work emphasises the importance of anatomical parameters on drug intranasal deposition and the need to evaluate inhaled drugs on different 3D nasal casts reflecting the target population.</div></div>","PeriodicalId":14187,"journal":{"name":"International Journal of Pharmaceutics","volume":"667 ","pages":"Article 124851"},"PeriodicalIF":5.3000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterization of anatomical variations of the nasal cavity in a subset of European patients and their impact on intranasal drug delivery\",\"authors\":\"Mike Pasteur ,&nbsp;Guillaume Arsouze ,&nbsp;Guy Ilango ,&nbsp;Déborah Le Pennec ,&nbsp;Dimitri Kulker ,&nbsp;Anaïs Heyraud ,&nbsp;Jean-Philippe Cottier ,&nbsp;Charles Aussedat ,&nbsp;Nathalie Heuzé-Vourc’h ,&nbsp;Virginie Hervé ,&nbsp;Sandrine Le Guellec\",\"doi\":\"10.1016/j.ijpharm.2024.124851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Anatomical 3D-printed nasal casts are valuable models to investigate intranasal drug deposition, providing preclinical data that cannot be obtained in animal models. However, these models are limited since they are often derived from a single patient or represent a mean of several groups. The present study aimed to better characterize the anatomical differences of the nasal cavity in a European sub-population and to assess the potential impact of anatomical variations on intranasal deposition by medical devices. Ninety-eight cranial computed tomography scans of patients were selected and analyzed in 2D and 3D conformations. They showed symmetry of cavities and a high level of heterogeneity of measurements, especially volume and area, in the population. Three anatomical groups with distinct nasal geometry were identified and 3D nasal casts of the most representative patient of each group were printed. Fluorescein was administered using three medical devices: a nasal spray, a sonic jet nebulizer and a prototype mesh-nebulizer. The deposition profiles were compared with the Aeronose® as a reference. Our results show that anatomical variations influenced the deposition profiles depending on the device, with a higher variation with spray and the mesh-nebulizer. This work emphasises the importance of anatomical parameters on drug intranasal deposition and the need to evaluate inhaled drugs on different 3D nasal casts reflecting the target population.</div></div>\",\"PeriodicalId\":14187,\"journal\":{\"name\":\"International Journal of Pharmaceutics\",\"volume\":\"667 \",\"pages\":\"Article 124851\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Pharmaceutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378517324010858\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378517324010858","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

解剖三维打印鼻腔模型是研究鼻内药物沉积的宝贵模型,可提供动物模型无法获得的临床前数据。然而,这些模型往往来自单一患者或代表几组患者的平均值,因此存在局限性。本研究旨在更好地描述欧洲亚人群鼻腔的解剖学差异,并评估解剖学差异对医疗器械鼻内沉积的潜在影响。研究人员选取了 98 名患者的头颅计算机断层扫描图像,并对其进行了二维和三维构型分析。扫描结果显示,患者的鼻腔具有对称性,测量结果(尤其是体积和面积)具有高度异质性。确定了具有不同鼻腔几何形状的三个解剖学组别,并为每个组别中最具代表性的患者打印了三维鼻腔模型。使用三种医疗设备施用荧光素:鼻腔喷雾器、声波喷射雾化器和原型网状雾化器。以 Aeronose® 为参照,对沉积曲线进行了比较。我们的研究结果表明,解剖结构的变化对沉积曲线的影响取决于不同的设备,喷雾器和网状雾化器的沉积曲线变化较大。这项工作强调了解剖参数对药物鼻内沉积的重要性,以及在反映目标人群的不同 3D 鼻腔模型上评估吸入药物的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterization of anatomical variations of the nasal cavity in a subset of European patients and their impact on intranasal drug delivery
Anatomical 3D-printed nasal casts are valuable models to investigate intranasal drug deposition, providing preclinical data that cannot be obtained in animal models. However, these models are limited since they are often derived from a single patient or represent a mean of several groups. The present study aimed to better characterize the anatomical differences of the nasal cavity in a European sub-population and to assess the potential impact of anatomical variations on intranasal deposition by medical devices. Ninety-eight cranial computed tomography scans of patients were selected and analyzed in 2D and 3D conformations. They showed symmetry of cavities and a high level of heterogeneity of measurements, especially volume and area, in the population. Three anatomical groups with distinct nasal geometry were identified and 3D nasal casts of the most representative patient of each group were printed. Fluorescein was administered using three medical devices: a nasal spray, a sonic jet nebulizer and a prototype mesh-nebulizer. The deposition profiles were compared with the Aeronose® as a reference. Our results show that anatomical variations influenced the deposition profiles depending on the device, with a higher variation with spray and the mesh-nebulizer. This work emphasises the importance of anatomical parameters on drug intranasal deposition and the need to evaluate inhaled drugs on different 3D nasal casts reflecting the target population.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.70
自引率
8.60%
发文量
951
审稿时长
72 days
期刊介绍: The International Journal of Pharmaceutics is the third most cited journal in the "Pharmacy & Pharmacology" category out of 366 journals, being the true home for pharmaceutical scientists concerned with the physical, chemical and biological properties of devices and delivery systems for drugs, vaccines and biologicals, including their design, manufacture and evaluation. This includes evaluation of the properties of drugs, excipients such as surfactants and polymers and novel materials. The journal has special sections on pharmaceutical nanotechnology and personalized medicines, and publishes research papers, reviews, commentaries and letters to the editor as well as special issues.
期刊最新文献
Liposomes-mediated enhanced antitumor effect of docetaxel with BRD4-PROTAC as synergist for breast cancer chemotherapy/immunotherapy. A four in one nanoplatform: Theranostic bismuth-containing nanoMOFs for chemo-photodynamic- radiation therapy and CT scan imaging. Cyclodextrin complexation as a fruitful strategy for improving the performance of nebivolol delivery from solid lipid nanoparticles. Human and canine osteosarcoma cell lines: How do they react upon incubation with calcium phosphate-coated lipid nanoparticles carrying doxorubicin and curcumin? Machine learning strengthened formulation design of pharmaceutical suspensions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1