Miao Liu, Xiangyu Jia, Rongfei Peng, Zhijun Bai, Jun Yuan, Lei Tan
{"title":"利用支撑液萃取和气相色谱-串联质谱法对血清多溴联苯醚进行人体生物监测。","authors":"Miao Liu, Xiangyu Jia, Rongfei Peng, Zhijun Bai, Jun Yuan, Lei Tan","doi":"10.1002/jssc.70010","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>This study aims to develop and validate a robust analytical method for the quantification of polybrominated diphenyl ethers (PBDEs) in human serum using gas chromatography–tandem mass spectrometry. We compared procedural blanks, recoveries, and operational convenience of liquid–liquid extraction and supported liquid extraction for the determination of serum PBDEs. We evaluated different extraction solvents for their effect on PBDE recoveries. Supported liquid extraction was selected for method validation due to its operational convenience. The method demonstrated satisfactory linearity, sensitivity, and reproducibility, with the range of 0.10–5.00 µg/L for most PBDE congeners and 0.20–10.0 µg/L for PBDE-154 and PBDE-183, with limits of detection ranging from 2 to 48 ng/L, and with matrix effects ranging from 94% to 113%. Quality control assessments indicated that recoveries ranged from 85% to 110% and relative standard deviations of less than 11%. The proposed method was applied to biomonitoring of 111 healthy adults, revealing detectable levels of PBDEs in over 90% of the samples. BDE-47 and BDE-183 were the most prevalent, with mean concentrations of 4.13 and 22.1 ng/L, respectively. Detection frequencies ranged from 0.90% for BDE-17 and BDE-85 to 25.2% for BDE-47. Males had higher mean concentrations of BDE-183 than females.</p>\n </div>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry\",\"authors\":\"Miao Liu, Xiangyu Jia, Rongfei Peng, Zhijun Bai, Jun Yuan, Lei Tan\",\"doi\":\"10.1002/jssc.70010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>This study aims to develop and validate a robust analytical method for the quantification of polybrominated diphenyl ethers (PBDEs) in human serum using gas chromatography–tandem mass spectrometry. We compared procedural blanks, recoveries, and operational convenience of liquid–liquid extraction and supported liquid extraction for the determination of serum PBDEs. We evaluated different extraction solvents for their effect on PBDE recoveries. Supported liquid extraction was selected for method validation due to its operational convenience. The method demonstrated satisfactory linearity, sensitivity, and reproducibility, with the range of 0.10–5.00 µg/L for most PBDE congeners and 0.20–10.0 µg/L for PBDE-154 and PBDE-183, with limits of detection ranging from 2 to 48 ng/L, and with matrix effects ranging from 94% to 113%. Quality control assessments indicated that recoveries ranged from 85% to 110% and relative standard deviations of less than 11%. The proposed method was applied to biomonitoring of 111 healthy adults, revealing detectable levels of PBDEs in over 90% of the samples. BDE-47 and BDE-183 were the most prevalent, with mean concentrations of 4.13 and 22.1 ng/L, respectively. Detection frequencies ranged from 0.90% for BDE-17 and BDE-85 to 25.2% for BDE-47. Males had higher mean concentrations of BDE-183 than females.</p>\\n </div>\",\"PeriodicalId\":17098,\"journal\":{\"name\":\"Journal of separation science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of separation science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70010\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70010","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry
This study aims to develop and validate a robust analytical method for the quantification of polybrominated diphenyl ethers (PBDEs) in human serum using gas chromatography–tandem mass spectrometry. We compared procedural blanks, recoveries, and operational convenience of liquid–liquid extraction and supported liquid extraction for the determination of serum PBDEs. We evaluated different extraction solvents for their effect on PBDE recoveries. Supported liquid extraction was selected for method validation due to its operational convenience. The method demonstrated satisfactory linearity, sensitivity, and reproducibility, with the range of 0.10–5.00 µg/L for most PBDE congeners and 0.20–10.0 µg/L for PBDE-154 and PBDE-183, with limits of detection ranging from 2 to 48 ng/L, and with matrix effects ranging from 94% to 113%. Quality control assessments indicated that recoveries ranged from 85% to 110% and relative standard deviations of less than 11%. The proposed method was applied to biomonitoring of 111 healthy adults, revealing detectable levels of PBDEs in over 90% of the samples. BDE-47 and BDE-183 were the most prevalent, with mean concentrations of 4.13 and 22.1 ng/L, respectively. Detection frequencies ranged from 0.90% for BDE-17 and BDE-85 to 25.2% for BDE-47. Males had higher mean concentrations of BDE-183 than females.
期刊介绍:
The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.