Ibrahim F. Abo-Elmagd, Amr M. Mahmoud, Medhat A. Al-Ghobashy, Marianne Nebsen, Mostafa A. Rabie, Ahmed F. Mohamed, Lamiaa A. Ahmed, Nesrine S. El Sayed, Reem K. Arafa, Robert Todd, Salwa A. Elgebaly
{"title":"开发并验证测定大鼠心脏组织中环磷酸肌酸及其相关内源性生物大分子的 LC-MS/MS 方法。","authors":"Ibrahim F. Abo-Elmagd, Amr M. Mahmoud, Medhat A. Al-Ghobashy, Marianne Nebsen, Mostafa A. Rabie, Ahmed F. Mohamed, Lamiaa A. Ahmed, Nesrine S. El Sayed, Reem K. Arafa, Robert Todd, Salwa A. Elgebaly","doi":"10.1186/s13065-024-01304-1","DOIUrl":null,"url":null,"abstract":"<div><p>The cardioprotective drug cyclocreatine phosphate has been awarded Food and Drug Administration-orphan drug designation for the prevention of ischemic injury to enhance cardiac graft recovery and survival in heart transplantation. Cyclocreatine phosphate is the water-soluble derivative of cyclocreatine. Estimating the levels of Cyclocreatine phosphate, Adenosine triphosphate, Creatine Phosphate, Creatine and Cyclocreatine helps us in understanding the energy state as well as evaluating the heart cells’ function. The quantification of endogenous compounds imposes a challenging task for analysts because of the absence of a true blank matrix, whose use is required according to international guidelines. Recently, the International Council for Harmonization issued a new guideline that contains guidance on the validation of methods used to quantify endogenous components, such as the background subtraction approach that was employed in our current study. Specifically, we developed and validated a sensitive, reliable and accurate liquid chromatography-tandem mass spectrometry assay to determine simultaneously the levels of mentioned endogenous compounds in rat heart tissue. Tissue samples were prepared by protein precipitation extraction using water: methanol (1:1). Using Ultra Performance Liquid Chromatography, Chromatographic separation was achieved with ZORBAX Eclipse Plus C18 4.6 × 100 mm,3.5 μm column and conditions as following: ammonium acetate (pH 8.5): acetonitrile, 70:30 mobile phase, 0.7 mL/min flow rate and 25 °C temperature. Electrospray ionization mass detector with Multiple reaction monitoring mode was then employed, using both positive and negative modes, Analysis was carried out using 5.00–2000.00 ng/mL linear concentration range within 2 min for each analyte. According to Food and Drug Administration guidelines for bioanalytical methods, validation was carried out. We investigated the matrix effect, recovery efficiency and process efficiency for the analyte in neat solvent, postextraction matrix and tissue. The results stated mean percentage recoveries higher than 99%, accuracy 93.32–111.99%, and Relative Standard Deviation (RSD) below 15% within the concentration range of our study which indicated that target analytes’ stability in their real matrix is sufficient under the employed experimental conditions.</p></div>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"18 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-024-01304-1","citationCount":"0","resultStr":"{\"title\":\"Development and validation of an LC‒MS/MS method for the determination of cyclocreatine phosphate and its related endogenous biomolecules in rat heart tissues\",\"authors\":\"Ibrahim F. Abo-Elmagd, Amr M. Mahmoud, Medhat A. Al-Ghobashy, Marianne Nebsen, Mostafa A. Rabie, Ahmed F. Mohamed, Lamiaa A. Ahmed, Nesrine S. El Sayed, Reem K. Arafa, Robert Todd, Salwa A. Elgebaly\",\"doi\":\"10.1186/s13065-024-01304-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The cardioprotective drug cyclocreatine phosphate has been awarded Food and Drug Administration-orphan drug designation for the prevention of ischemic injury to enhance cardiac graft recovery and survival in heart transplantation. Cyclocreatine phosphate is the water-soluble derivative of cyclocreatine. Estimating the levels of Cyclocreatine phosphate, Adenosine triphosphate, Creatine Phosphate, Creatine and Cyclocreatine helps us in understanding the energy state as well as evaluating the heart cells’ function. The quantification of endogenous compounds imposes a challenging task for analysts because of the absence of a true blank matrix, whose use is required according to international guidelines. Recently, the International Council for Harmonization issued a new guideline that contains guidance on the validation of methods used to quantify endogenous components, such as the background subtraction approach that was employed in our current study. Specifically, we developed and validated a sensitive, reliable and accurate liquid chromatography-tandem mass spectrometry assay to determine simultaneously the levels of mentioned endogenous compounds in rat heart tissue. Tissue samples were prepared by protein precipitation extraction using water: methanol (1:1). Using Ultra Performance Liquid Chromatography, Chromatographic separation was achieved with ZORBAX Eclipse Plus C18 4.6 × 100 mm,3.5 μm column and conditions as following: ammonium acetate (pH 8.5): acetonitrile, 70:30 mobile phase, 0.7 mL/min flow rate and 25 °C temperature. Electrospray ionization mass detector with Multiple reaction monitoring mode was then employed, using both positive and negative modes, Analysis was carried out using 5.00–2000.00 ng/mL linear concentration range within 2 min for each analyte. According to Food and Drug Administration guidelines for bioanalytical methods, validation was carried out. We investigated the matrix effect, recovery efficiency and process efficiency for the analyte in neat solvent, postextraction matrix and tissue. The results stated mean percentage recoveries higher than 99%, accuracy 93.32–111.99%, and Relative Standard Deviation (RSD) below 15% within the concentration range of our study which indicated that target analytes’ stability in their real matrix is sufficient under the employed experimental conditions.</p></div>\",\"PeriodicalId\":496,\"journal\":{\"name\":\"BMC Chemistry\",\"volume\":\"18 1\",\"pages\":\"\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-024-01304-1\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s13065-024-01304-1\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-024-01304-1","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Development and validation of an LC‒MS/MS method for the determination of cyclocreatine phosphate and its related endogenous biomolecules in rat heart tissues
The cardioprotective drug cyclocreatine phosphate has been awarded Food and Drug Administration-orphan drug designation for the prevention of ischemic injury to enhance cardiac graft recovery and survival in heart transplantation. Cyclocreatine phosphate is the water-soluble derivative of cyclocreatine. Estimating the levels of Cyclocreatine phosphate, Adenosine triphosphate, Creatine Phosphate, Creatine and Cyclocreatine helps us in understanding the energy state as well as evaluating the heart cells’ function. The quantification of endogenous compounds imposes a challenging task for analysts because of the absence of a true blank matrix, whose use is required according to international guidelines. Recently, the International Council for Harmonization issued a new guideline that contains guidance on the validation of methods used to quantify endogenous components, such as the background subtraction approach that was employed in our current study. Specifically, we developed and validated a sensitive, reliable and accurate liquid chromatography-tandem mass spectrometry assay to determine simultaneously the levels of mentioned endogenous compounds in rat heart tissue. Tissue samples were prepared by protein precipitation extraction using water: methanol (1:1). Using Ultra Performance Liquid Chromatography, Chromatographic separation was achieved with ZORBAX Eclipse Plus C18 4.6 × 100 mm,3.5 μm column and conditions as following: ammonium acetate (pH 8.5): acetonitrile, 70:30 mobile phase, 0.7 mL/min flow rate and 25 °C temperature. Electrospray ionization mass detector with Multiple reaction monitoring mode was then employed, using both positive and negative modes, Analysis was carried out using 5.00–2000.00 ng/mL linear concentration range within 2 min for each analyte. According to Food and Drug Administration guidelines for bioanalytical methods, validation was carried out. We investigated the matrix effect, recovery efficiency and process efficiency for the analyte in neat solvent, postextraction matrix and tissue. The results stated mean percentage recoveries higher than 99%, accuracy 93.32–111.99%, and Relative Standard Deviation (RSD) below 15% within the concentration range of our study which indicated that target analytes’ stability in their real matrix is sufficient under the employed experimental conditions.
期刊介绍:
BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family.
Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.