Dingbang Chen, Jinhan Song, Luosheng Zhang, Xin Gao, Quan Huang, Xinghai Yang
{"title":"使用生物可吸收材料和钛材料进行短层膜再植内固定的安全性和可行性:临床对比研究。","authors":"Dingbang Chen, Jinhan Song, Luosheng Zhang, Xin Gao, Quan Huang, Xinghai Yang","doi":"10.1111/os.14288","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Lamina-implantation is gradually becoming the main surgical method for the treatment of intraspinal tumors. Traditional titanium (Ti) internal fixation not only produces artifacts, which affects the observation of tumors and dural sac closure, but also faces the problem of secondary surgical removal. In this study, absorbable material were used in lamina replantation for the first time and was evaluated for its efficacy and safety.</p><p><strong>Methods: </strong>We retrospectively enrolled patients who underwent short-segment lamina replantation for intraspinal tumors in our center from February 2020 to November 2022. After condition matching of the number of fixation segment and fixation position, the baseline information, complications, neurological function, quality of life, spinal mobility and bone healing rate of the absorbable group and the Ti group were compared. Fisher exact, Chi-square, or rank sum test were used for categorical variables, and t-test was used for continuous variables to distinguish differences between groups.</p><p><strong>Results: </strong>Cerebrospinal fluid leak was the most common complication, with no difference between the two groups (12.9% vs. 19.4%, p = 0.366). The bone healing rates of the two groups at 3 months after surgery were 77.4% and 87.1%, respectively, and there was no significant difference (p = 0.508). At 1 year after surgery, the resorbable group showedlower levels of anxiety/depression (1.20 ± 0.41 vs. 1.61 ± 0.61, p = 0.050), however, it did not affect the overall quality of life of the patients at 1 year.</p><p><strong>Conclusion: </strong>Both titanium and absorbable internal fixation have shown good clinical results in the treatment of intraspinal tumors by laminareplantation. Regardless of cost, absorbable screws and plates are also suitable options for patients undergoing lamina replantation, because it has no stress shielding effect and does not require secondary removal. In addition, there are no artifacts in the image, which is more conducive to observing the recurrence of the tumor and the closure of the dural sac.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety and Feasibility of Internal Fixation Using Bioabsorbable Versus Titanium Materials for Short-Level Lamina Reimplantation: A Comparative Clinical Study.\",\"authors\":\"Dingbang Chen, Jinhan Song, Luosheng Zhang, Xin Gao, Quan Huang, Xinghai Yang\",\"doi\":\"10.1111/os.14288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Lamina-implantation is gradually becoming the main surgical method for the treatment of intraspinal tumors. Traditional titanium (Ti) internal fixation not only produces artifacts, which affects the observation of tumors and dural sac closure, but also faces the problem of secondary surgical removal. In this study, absorbable material were used in lamina replantation for the first time and was evaluated for its efficacy and safety.</p><p><strong>Methods: </strong>We retrospectively enrolled patients who underwent short-segment lamina replantation for intraspinal tumors in our center from February 2020 to November 2022. After condition matching of the number of fixation segment and fixation position, the baseline information, complications, neurological function, quality of life, spinal mobility and bone healing rate of the absorbable group and the Ti group were compared. Fisher exact, Chi-square, or rank sum test were used for categorical variables, and t-test was used for continuous variables to distinguish differences between groups.</p><p><strong>Results: </strong>Cerebrospinal fluid leak was the most common complication, with no difference between the two groups (12.9% vs. 19.4%, p = 0.366). The bone healing rates of the two groups at 3 months after surgery were 77.4% and 87.1%, respectively, and there was no significant difference (p = 0.508). At 1 year after surgery, the resorbable group showedlower levels of anxiety/depression (1.20 ± 0.41 vs. 1.61 ± 0.61, p = 0.050), however, it did not affect the overall quality of life of the patients at 1 year.</p><p><strong>Conclusion: </strong>Both titanium and absorbable internal fixation have shown good clinical results in the treatment of intraspinal tumors by laminareplantation. Regardless of cost, absorbable screws and plates are also suitable options for patients undergoing lamina replantation, because it has no stress shielding effect and does not require secondary removal. In addition, there are no artifacts in the image, which is more conducive to observing the recurrence of the tumor and the closure of the dural sac.</p>\",\"PeriodicalId\":19566,\"journal\":{\"name\":\"Orthopaedic Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/os.14288\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.14288","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
目的:层状内固定术逐渐成为治疗椎管内肿瘤的主要手术方法。传统的钛(Ti)内固定不仅会产生假象,影响肿瘤的观察和硬膜囊的闭合,还面临二次手术切除的问题。在这项研究中,首次将可吸收材料用于薄层再植,并对其有效性和安全性进行了评估:方法:我们回顾性地纳入了2020年2月至2022年11月在本中心接受短节段椎管内肿瘤椎板再植术的患者。在对固定节段数和固定位置进行条件匹配后,比较可吸收组和 Ti 组的基线资料、并发症、神经功能、生活质量、脊柱活动度和骨愈合率。分类变量采用费舍尔精确检验、卡方检验或秩和检验,连续变量采用t检验,以区分组间差异:结果:脑脊液漏是最常见的并发症,两组间无差异(12.9% vs. 19.4%,P = 0.366)。术后3个月,两组的骨愈合率分别为77.4%和87.1%,无明显差异(P = 0.508)。术后1年,可吸收组的焦虑/抑郁水平较低(1.20 ± 0.41 vs. 1.61 ± 0.61,p = 0.050),但这并不影响患者术后1年的整体生活质量:钛合金内固定和可吸收内固定在椎板内固定治疗椎管内肿瘤中均显示出良好的临床效果。无论费用高低,可吸收螺钉和钢板也是椎板再植术患者的合适选择,因为它没有应力屏蔽效应,也不需要二次移除。此外,图像中没有伪影,更有利于观察肿瘤的复发和硬膜囊的闭合情况。
Safety and Feasibility of Internal Fixation Using Bioabsorbable Versus Titanium Materials for Short-Level Lamina Reimplantation: A Comparative Clinical Study.
Objective: Lamina-implantation is gradually becoming the main surgical method for the treatment of intraspinal tumors. Traditional titanium (Ti) internal fixation not only produces artifacts, which affects the observation of tumors and dural sac closure, but also faces the problem of secondary surgical removal. In this study, absorbable material were used in lamina replantation for the first time and was evaluated for its efficacy and safety.
Methods: We retrospectively enrolled patients who underwent short-segment lamina replantation for intraspinal tumors in our center from February 2020 to November 2022. After condition matching of the number of fixation segment and fixation position, the baseline information, complications, neurological function, quality of life, spinal mobility and bone healing rate of the absorbable group and the Ti group were compared. Fisher exact, Chi-square, or rank sum test were used for categorical variables, and t-test was used for continuous variables to distinguish differences between groups.
Results: Cerebrospinal fluid leak was the most common complication, with no difference between the two groups (12.9% vs. 19.4%, p = 0.366). The bone healing rates of the two groups at 3 months after surgery were 77.4% and 87.1%, respectively, and there was no significant difference (p = 0.508). At 1 year after surgery, the resorbable group showedlower levels of anxiety/depression (1.20 ± 0.41 vs. 1.61 ± 0.61, p = 0.050), however, it did not affect the overall quality of life of the patients at 1 year.
Conclusion: Both titanium and absorbable internal fixation have shown good clinical results in the treatment of intraspinal tumors by laminareplantation. Regardless of cost, absorbable screws and plates are also suitable options for patients undergoing lamina replantation, because it has no stress shielding effect and does not require secondary removal. In addition, there are no artifacts in the image, which is more conducive to observing the recurrence of the tumor and the closure of the dural sac.
期刊介绍:
Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery.
The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.